About Wire and Cable
More
Low-Voltage Cable
- Use For: Appliances, Vehicles
- Flexible
- Temperature Range: -40° to 175° F
- Insulation: PVC Plastic
Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Wd. | Thick. | Outer Insulation Color | Industry Designation | Length, ft. | 1-249 | 250-Up | |
Stranded Wire | ||||||||||
12V DC | ||||||||||
24 | 2 | 24/2 | 0.11" | 0.06" | Black, Red | GPT | 000000 | 00000 | 00000 | |
22 | 2 | 22/2 | 0.16" | 0.07" | Black, Red | GPT | 0000000 | 000 | 000 | |
20 | 2 | 20/2 | 0.17" | 0.08" | Black, Red | GPT | 0000000 | 000 | 000 | |
18 | 2 | 18/2 | 0.21" | 0.1" | Black, Red | GPT | 000000 | 000 | 000 | |
16 | 2 | 16/2 | 0.24" | 0.12" | Black, Red | GPT | 0000000 | 000 | 000 | |
14 | 2 | 14/2 | 0.29" | 0.15" | Black, Red | GPT | 000000 | 000 | 000 | |
12 | 2 | 12/2 | 0.33" | 0.16" | Black, Red | GPT | 000000 | 0000 | 000 | |
10 | 2 | 10/2 | 0.4" | 0.2" | Black, Red | GPT | 000000 | 0000 | 0000 | |
8 | 2 | 8/2 | 0.49" | 0.25" | Black, Red | GPT | 000000 | 0000 | 0000 | |
6 | 2 | 6/2 | 0.69" | 0.32" | Black, Red | GPT | 0000000 | 0000 | 0000 | |
4 | 2 | 4/2 | 0.89" | 0.43" | Black, Red | GPT | 0000000 | 0000 | 0000 | |
2 | 2 | 2/2 | 0.97" | 0.45" | Black, Red | GPT | 0000000 | 0000 | 0000 |
Battery Wire
Connect batteries in vehicles and generators.
Strand count is the number of strands followed by the size of the individual strand.
Wire with a PVC plastic insulation resists fuel and oil.
Wire with an EPDM rubber insulation is ultra-flexible for use in applications that require tight turns. The insulation resists abrasion and oil.
Wire with a cross-linked polyolefin (XLPO) insulation is ultra-flexible and withstands high heat, making it suitable for applications such as vehicle engine wiring.
SAE wire meets standards for low-voltage wiring in vehicle electrical systems.
For technical drawings and 3-D models, click on a part number.
- Use for vehicles
- Flexible
- Temperature Range: -40° to 190° F
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
60V DC | ||||||||||
8 | 19/21 | 57 A @ 86° F | 0.22" | SGT | SAE J1128 | 0000000 | 00000 | 00000 | ||
6 | 48/22.5 | 82 A @ 86° F | 0.33" | SGT | SAE J1127 | 0000000 | 0000 | 0000 | ||
4 | 70/22.5 | 110 A @ 86° F | 0.38" | SGT | SAE J1127 | 0000000 | 0000 | 0000 | ||
2 | 64/20 | 147 A @ 86° F | 0.45" | SGT | SAE J1127 | 0000000 | 0000 | 0000 | ||
1 | 133/22 | 172 A @ 86° F | 0.49" | SGT | SAE J1127 | 0000000 | 0000 | 0000 | ||
1/0 | 210/23 | 200 A @ 86° F | 0.55" | SGT | SAE J1127 | 0000000 | 0000 | 0000 | ||
2/0 | 133/20 | 233 A @ 86° F | 0.61" | SGT | SAE J1127 | 0000000 | 00000 | 0000 | ||
3/0 | 259/22 | 270 A @ 86° F | 0.66" | SGT | SAE J1127 | 0000000 | 00000 | 00000 | ||
4/0 | 418/23 | 315 A @ 86° F | 0.73" | SGT | SAE J1127 | 0000000 | 00000 | 00000 |
- Use for vehicles
- Ultra Flexible
- Temperature Range: -40° to 190° F
Per Ft. | ||||||||
---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Choose an Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
600V AC/600V DC | ||||||||
6 | 259/30 | 105 A @ 86° F | 0.31" | 0000000 | 00000 | 00000 | ||
4 | 385/30 | 140 A @ 86° F | 0.34" | 0000000 | 0000 | 0000 | ||
2 | 651/30 | 190 A @ 86° F | 0.42" | 0000000 | 0000 | 0000 | ||
1 | 798/30 | 220 A @ 86° F | 0.49" | 0000000 | 0000 | 0000 | ||
1/0 | 1,026/30 | 260 A @ 86° F | 0.54" | 0000000 | 0000 | 0000 | ||
2/0 | 1,254/30 | 300 A @ 86° F | 0.59" | 0000000 | 0000 | 0000 | ||
3/0 | 1,615/30 | 350 A @ 86° F | 0.64" | 0000000 | 00000 | 0000 | ||
4/0 | 2,052/30 | 405 A @ 86° F | 0.72" | 0000000 | 00000 | 00000 |
- Use for vehicles
- Ultra Flexible
- Temperature Range: -40° to 255° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
60V AC | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
6 | 133/27 | Not Rated | 0.3" | SGX | SAE J1654 | 0000000 | |||||
4 | 133/25 | Not Rated | 0.36" | SGX | SAE J1654 | 0000000 | |||||
2 | 133/24 | Not Rated | 0.43" | SGX | SAE J1654 | 0000000 | |||||
1/0 | 1,026/30 | Not Rated | 0.52" | SGX | SAE J1654 | 0000000 | |||||
2/0 | 1,254/30 | Not Rated | 0.57" | SGX | SAE J1654 | 0000000 | |||||
3/0 | 1,615/30 | Not Rated | 0.65" | SGX | SAE J1654 | 0000000 | |||||
4/0 | 2,052/30 | Not Rated | 0.71" | SGX | SAE J1654 | 0000000 |
Vehicle Wire
Originally designed to meet the quality standards of the auto industry, this wire withstands high temperatures, flames, and abrasion. Unlike other low-voltage wires, this wire meets strict SAE performance requirements. You'll often hear it referred to as primary wire in trucks, trailers, forklifts, and other vehicles.
In protected environments, such as vehicle interiors, GPT wire is the best choice.
For wiring exposed to weather and wear and tear, choose a wire with polyethylene insulation. For these applications, GXL wire is the standard choice, as it balances flexibility and abrasion-resistance. TXL wire has a thinner insulation, making it easy to maneuver in tight spaces. SXL wire has a thicker insulation and is the most durable. It can withstand repeated exposure to heat, dust, chemicals, and salt.
For technical drawings and 3-D models, click on a part number.
- Use for vehicles
- Flexible
- Temperature Range: -10° to 175° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
20 | 10/30 | 9 A @ 86° F | 0.09" | GPT | SAE J1128 | 100 | 0000000 | 000000 | |
18 | 16/30 | 17 A @ 86° F | 0.1" | GPT | SAE J1128 | 45 | 0000000 | 0000 | |
18 | 16/30 | 17 A @ 86° F | 0.1" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
16 | 19/29 | 21 A @ 86° F | 0.11" | GPT | SAE J1128 | 35 | 0000000 | 0000 | |
16 | 19/29 | 21 A @ 86° F | 0.11" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
14 | 19/27 | 29 A @ 86° F | 0.12" | GPT | SAE J1128 | 20 | 0000000 | 0000 | |
14 | 19/27 | 29 A @ 86° F | 0.12" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
12 | 19/25 | 38 A @ 86° F | 0.15" | GPT | SAE J1128 | 12 | 0000000 | 0000 | |
12 | 19/25 | 38 A @ 86° F | 0.15" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
10 | 19/23 | 51 A @ 86° F | 0.18" | GPT | SAE J1128 | 8 | 0000000 | 0000 | |
10 | 19/23 | 51 A @ 86° F | 0.18" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
8 | 19/21 | 51 A @ 86° F | 0.22" | GPT | SAE J1128 | 8 | 000000 | 0000 | |
8 | 19/21 | 51 A @ 86° F | 0.22" | GPT | SAE J1128 | 100 | 000000 | 00000 |
- Use for vehicles
- Flexible
- Temperature Range: -40° to 255° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 25 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 50 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 100 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 250 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 500 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 25 | 000000 | 0000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 50 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 100 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 250 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 500 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 25 | 00000000 | 0000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 250 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 500 | 00000000 | 000000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 25 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 250 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 500 | 00000000 | 000000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 25 | 00000000 | 00000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 250 | 00000000 | 000000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 500 | 00000000 | 000000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 25 | 00000000 | 00000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 250 | 00000000 | 000000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 500 | 00000000 | 000000 |
- Use for vehicles
- Flexible
- Temperature Range: -40° to 255° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 25 | 000000 | 00000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 50 | 000000 | 0000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 100 | 000000 | 00000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 250 | 000000 | 00000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 500 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 25 | 000000 | 0000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 50 | 000000 | 0000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 100 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 250 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 500 | 00000000 | 00000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 25 | 00000000 | 0000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 50 | 00000000 | 0000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 250 | 00000000 | 00000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 500 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 25 | 00000000 | 0000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 50 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 250 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 500 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 25 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 50 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 250 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 500 | 00000000 | 000000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 25 | 00000000 | 00000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 50 | 00000000 | 00000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 250 | 00000000 | 000000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 500 | 00000000 | 000000 |
- Use for vehicles
- Flexible
- Temperature Range: -40° to 255° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
18 | 16/30 | 20 A @ 86° F | 0.11" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
18 | 16/30 | 20 A @ 86° F | 0.11" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
16 | 19/29 | 26 A @ 86° F | 0.12" | SXL | SAE J1128 | 25 | 0000000 | 0000 | |
16 | 19/29 | 26 A @ 86° F | 0.12" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
14 | 19/27 | 40 A @ 86° F | 0.14" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
14 | 19/27 | 40 A @ 86° F | 0.14" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
12 | 19/25 | 50 A @ 86° F | 0.16" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
12 | 19/25 | 50 A @ 86° F | 0.16" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
10 | 19/23 | 70 A @ 86° F | 0.19" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
10 | 19/23 | 70 A @ 86° F | 0.19" | SXL | SAE J1128 | 100 | 0000000 | 00000 |
Vehicle Wire Assortments
- Use for vehicles
- Flexible
- Temperature Range:
GPT Wire: -40° to 185° F
TXL and GXL Wire: -40° to 255° F
Keep spools of vehicle wire in multiple colors on hand. They meet SAE J1128 for low-voltage wiring in trucks, boats, trailers, and other vehicles.
GPT wire, or primary wire, has PVC insulation that makes it useful as a general purpose wire.
TXL and GXL wire have cross-linked polyethylene insulation that withstands higher temperatures and has more abrasion resistance than PVC insulation. TXL wire has thin walls, so it’s small and lightweight. It’s often used for dashboards and other car interior applications. GXL wire has thick walls, making it suitable for engine compartments.
No. of Spools | Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Length, ft. | Specifications Met | Each | |
GPT Stranded Wire with PVC Plastic Insulation | |||||||||
---|---|---|---|---|---|---|---|---|---|
25V AC/60V DC | |||||||||
5 | 22 | 7/30 | 3 A @ 86° F | 0.08" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
5 | 20 | 7/28 | 5 A @ 86° F | 0.08" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 18 | 16/30 | 17 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 16 | 19/29 | 22 A @ 86° F | 0.11" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 14 | 19/27 | 30 A @ 86° F | 0.12" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 12 | 19/25 | 40 A @ 86° F | 0.14" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
5 | 10 | 19/23 | 55 A @ 86° F | 0.18" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
TXL Stranded Wire with Cross-Linked Polyethylene (XLPE) Insulation | |||||||||
25V AC/60V DC | |||||||||
5 | 22 | 7/30 | 3 A @ 86° F | 0.06" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 20 | 7/28 | 5 A @ 86° F | 0.07" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 18 | 16/30 | 7 A @ 86° F | 0.08" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 16 | 19/29 | 10 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 14 | 19/27 | 15 A @ 86° F | 0.1" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 12 | 19/25 | 20 A @ 86° F | 0.13" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
GXL Stranded Wire with Cross-Linked Polyethylene (XLPE) Insulation | |||||||||
25V AC/60V DC | |||||||||
5 | 20 | 7/28 | 5 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 18 | 16/30 | 5 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 16 | 19/29 | 8 A @ 86° F | 0.1" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 14 | 19/27 | 11 A @ 86° F | 0.12" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 12 | 19/25 | 14 A @ 86° F | 0.15" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
5 | 10 | 19/23 | 23 A @ 86° F | 0.18" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
Corrosion-Resistant Battery Wire
- Use for boats, vehicles
- Flexible
- Temperature Range: 0° to 220° F
Connect batteries in generators, forklifts, and other vehicles in corrosive environments. Also known as marine wire, this copper wire is tin plated to resist corrosion from salt water, battery acid, and oil. Designed for boats, it's a good choice for use outdoors. The PVC insulation stands up to fuel and oil. Strand count is the number of strands followed by the size of the individual strand.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire with PVC Plastic Insulation | ||||||||
---|---|---|---|---|---|---|---|---|
600V AC | ||||||||
8 | 133/29 | Not Rated | 0.16" | Red | 0000000 | |||
8 | 133/29 | Not Rated | 0.26" | Black | 0000000 | |||
6 | 133/27 | Not Rated | 0.32" | Red | 0000000 | |||
6 | 266/27 | Not Rated | 0.32" | Black | 0000000 | |||
4 | 133/25 | Not Rated | 0.36" | Red | 0000000 | |||
4 | 420/25 | Not Rated | 0.37" | Black | 0000000 | |||
2 | 665/30 | Not Rated | 0.43" | Red | 0000000 | |||
2 | 665/30 | Not Rated | 0.47" | Black | 0000000 |
Fusible Link Wire
- Use for vehicles
- Ultra Flexible
- Maximum Temperature: 300° F
Often found in older vehicles, this fusible link wire protects a circuit in applications where you can’t use a standard fuse. The conductor in the fusible link melts if there’s a short circuit or voltage spike, breaking the circuit to protect the rest of your wiring. Made of cross-linked polyethylene, the insulation withstands high temperatures and contains any sparks or flames caused by current overload. Since the conductor needs to be thin enough to melt before the rest of your wiring overheats, choose a fusible link wire that’s four gauge sizes smaller than your circuit. If you’re replacing a fusible link that has burned out, make sure the new wire is the same length and gauge as the old one.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Strand Count | OD | Specifications Met | Outer Insulation Color | Length, ft. | Each | |
Stranded Wire with Cross-Linked Polyethylene (XLPE) Insulation | |||||||
---|---|---|---|---|---|---|---|
12V DC | |||||||
18 | 19/23 | 0.02" | SAE J1128 | Blue | 8 | 00000000 | 00000 |
18 | 19/23 | 0.02" | SAE J1128 | Blue | 100 | 00000000 | 00000 |
16 | 19/30 | 0.04" | SAE J1128 | Black | 7 | 00000000 | 0000 |
16 | 19/30 | 0.04" | SAE J1128 | Black | 100 | 00000000 | 00000 |
14 | 19/28 | 0.08" | SAE J1128 | Gray | 6 | 00000000 | 0000 |
14 | 19/28 | 0.08" | SAE J1128 | Gray | 100 | 00000000 | 00000 |
12 | 19/25 | 0.12" | SAE J1128 | Blue | 4 | 00000000 | 0000 |
12 | 19/25 | 0.12" | SAE J1128 | Blue | 100 | 00000000 | 000000 |
10 | 16/18 | 0.2" | SAE J1128 | Red | 1 | 00000000 | 0000 |
10 | 16/18 | 0.2" | SAE J1128 | Red | 75 | 00000000 | 000000 |