About Wire and Cable
More
High-Temperature Cable
The insulation on this cable withstands high-heat applications such as ovens and furnaces. The wires are silver or nickel plated for corrosion resistance.
Use unshielded cable in applications where signal interference is not a concern. It has a layer of fiberglass fabric and mica tape around each wire. The entire cable is wrapped in a layer of fiberglass fabric and mica tape, and then covered in PTFE. The PTFE outer insulation resists chemicals, oil, abrasion, and moisture.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. It has PTFE outer and inner insulation that resists chemicals, oil, abrasion, and moisture.
- Use For: Ovens and Furnaces
- Flexible
- Temperature Range: -40° to 840° F
- Insulation:
Outer: Fiberglass Fabric, Mica, PTFE Plastic
Inner: Fiberglass Fabric, Mica
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||
18 | 2 | 18/2 | 9 A @ 700° F, 23 A @ 86° F | 0.32" | Black | Red/White, White/Black | 0000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 9 A @ 700° F, 23 A @ 86° F | 0.33" | Black | Blue/White, Red/White, White/Black | 0000000 | 00000 | 0000 | |
18 | 4 | 18/4 | 7 A @ 700° F, 18 A @ 86° F | 0.36" | Black | Blue/White, Orange/White, Red/White, White/Black | 0000000 | 00000 | 0000 | |
16 | 2 | 16/2 | 12 A @ 700° F, 30 A @ 86° F | 0.35" | Black | Red/White, White/Black | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 12 A @ 700° F, 30 A @ 86° F | 0.36" | Black | Blue/White, Red/White, White/Black | 0000000 | 00000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 700° F, 24 A @ 86° F | 0.4" | Black | Blue/White, Orange/White, Red/White, White/Black | 0000000 | 00000 | 00000 | |
14 | 2 | 14/2 | 18 A @ 700° F, 45 A @ 86° F | 0.37" | Black | Red/White, White/Black | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 700° F, 45 A @ 86° F | 0.39" | Black | Blue/White, Red/White, White/Black | 0000000 | 00000 | 00000 | |
14 | 4 | 14/4 | 15 A @ 700° F, 36 A @ 86° F | 0.42" | Black | Blue/White, Orange/White, Red/White, White/Black | 0000000 | 00000 | 00000 | |
12 | 2 | 12/2 | 23 A @ 700° F, 56 A @ 86° F | 0.41" | Black | Red/White, White/Black | 0000000 | 00000 | 0000 | |
12 | 3 | 12/3 | 23 A @ 700° F, 56 A @ 86° F | 0.43" | Black | Blue/White, Red/White, White/Black | 0000000 | 00000 | 00000 | |
12 | 4 | 12/4 | 18 A @ 700° F, 44 A @ 86° F | 0.47" | Black | Blue/White, Orange/White, Red/White, White/Black | 0000000 | 00000 | 00000 | |
10 | 2 | 10/2 | 31 A @ 700° F, 75 A @ 86° F | 0.53" | Black | Red/White, White/Black | 0000000 | 00000 | 00000 | |
10 | 3 | 10/3 | 31 A @ 700° F, 75 A @ 86° F | 0.57" | Black | Blue/White, Red/White, White/Black | 0000000 | 00000 | 00000 |
- Use For: Ovens and Furnaces, Interference Shielding
- Flexible
- Temperature Range: -65° to 390° F
- Insulation: PTFE Plastic
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
600V AC | |||||||||||
26 | 2 | 26/2 | 0.8 A @ 300° F, 1.6 A @ 86° F | 0.12" | White | Black, White | MIL-W-16878/4-Type E | 0000000 | 00000 | 00000 | |
26 | 3 | 26/3 | 0.8 A @ 300° F, 1.6 A @ 86° F | 0.13" | White | Black, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
26 | 4 | 26/4 | 0.6 A @ 600° F, 1.3 A @ 86° F | 0.14" | White | Black, Green, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
24 | 2 | 24/2 | 1.6 A @ 300° F, 3.3 A @ 86° F | 0.14" | White | Black, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
24 | 3 | 24/3 | 1.6 A @ 300° F, 3.3 A @ 86° F | 0.14" | White | Black, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
24 | 4 | 24/4 | 1.3 A @ 300° F, 2.6 A @ 86° F | 0.16" | White | Black, Green, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
22 | 2 | 22/2 | 2.4 A @ 300° F, 4.9 A @ 86° F | 0.15" | White | Black, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
22 | 3 | 22/3 | 2.4 A @ 300° F, 4.9 A @ 86° F | 0.15" | White | Black, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
22 | 4 | 22/4 | 1.9 A @ 300° F, 3.9 A @ 86° F | 0.17" | White | Black, Green, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
20 | 2 | 20/2 | 4 A @ 300° F, 8.2 A @ 86° F | 0.16" | White | Black, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
20 | 3 | 20/3 | 4 A @ 300° F, 8.2 A @ 86° F | 0.17" | White | Black, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
20 | 4 | 20/4 | 3.2 A @ 300° F, 6.6 A @ 86° F | 0.19" | White | Black, Green, Red, White | MIL-W-16878/4-Type E | 0000000 | 00000 | 0000 | |
18 | 2 | 18/2 | 5.6 A @ 300° F, 11.5 A @ 86° F | 0.19" | White | Black, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
18 | 3 | 18/3 | 5.6 A @ 300° F, 11.5 A @ 86° F | 0.2" | White | Black, Red, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 4.5 A @ 300° F, 9.2 A @ 86° F | 0.22" | White | Black, Green, Red, White | MIL-W-16878/4-Type E | 0000000 | 00000 | 0000 | |
16 | 2 | 16/2 | 8 A @ 300° F, 16.4 A @ 86° F | 0.21" | White | Black, White | MIL-W-16878/4-Type E | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 8 A @ 300° F, 16.4 A @ 86° F | 0.22" | White | Black, Red, White | MIL-W-16878/4-Type E | 0000000 | 00000 | 00000 | |
16 | 4 | 16/4 | 6.4 A @ 300° F, 13.1 A @ 86° F | 0.24" | White | Black, Green, Red, White | MIL-W-16878/4-Type E | 0000000 | 00000 | 00000 |
High-Temperature Continuous-Flex Cable
- Use For: Automation, Continuous Motion, Ovens and Furnaces
- Continuous Flex
- Temperature Range: -10° to 350° F
- Insulation:
Outer: Silicone Rubber
Inner: FEP Plastic
Bend and flex this silicone-insulated cable in temperatures up to 350° F. It can keep moving in areas twice as hot as most other continuous-flex cables without degrading data or signal transmission. It’s often used inside cable carriers in feeding lines for blast furnaces or in automated welding and cutting systems. This cable resists abrasion and won’t break down from exposure to chemicals and UV light. It meets IEC standards for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
For technical drawings and 3-D models, click on a part number.
High-Temperature Wire
- Use for ovens and furnaces
- Fiberglass Fabric Outer Insulation: Flexible
Ceramic Fabric Outer Insulation: Bend and Stay - Temperature Range: See table
Even at 480° F—hotter than some industrial ovens—this wire’s insulation won’t melt.
Wire with a fiberglass outer and mica inner insulation is the common choice for steel mills, iron mills, and glass manufacturing. You may know it as MG wire. Wire with a silicone-coated outer insulation shields your skin from fiberglass particles when handling the wire.
Wire with a fiberglass outer and PTFE inner insulation won’t corrode from moisture, so it’s often used in industrial drying equipment. It also won’t become brittle or crack from chemicals. This wire is commonly known as TGGT wire.
Wire with a ceramic fabric outer insulation withstands the hottest temperatures of our offering, so you can safely run it near open flames. It’s flame rated VW-1 to prevent the spread of fire. This wire won’t become brittle or crack from chemicals. Bend it and it stays in place.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | Min. Temp., °F | Max. Temp., °F | OD | Outer Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with Fiberglass Fabric Outer and Mica Inner Insulation | ||||||||||||
600V AC/600V DC | ||||||||||||
20 | 10/30 | 12 A @ 600° F 23 A @ 86° F | -40° | 840° | 0.11" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
18 | 16/30 | 17 A @ 600° F 31 A @ 86° F | -40° | 840° | 0.12" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
16 | 26/30 | 22 A @ 600° F 40 A @ 86° F | -40° | 840° | 0.13" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 41/30 | 30 A @ 600° F 55 A @ 86° F | -40° | 840° | 0.14" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
12 | 65/30 | 41 A @ 600° F 75 A @ 86° F | -40° | 840° | 0.16" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
10 | 105/30 | 100 A @ 86° F 55 A @ 600° F | -40° | 840° | 0.21" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
8 | 133/29 | 159 A @ 86° F 87 A @ 600° F | -40° | 840° | 0.27" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
6 | 133/27 | 133 A @ 600° F 242 A @ 86° F | -40° | 840° | 0.31" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
4 | 133/25 | 167 A @ 600° F 304 A @ 86° F | -40° | 840° | 0.37" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
2 | 133/23 | 230 A @ 600° F 419 A @ 86° F | -40° | 840° | 0.45" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Silicone-Coated Fiberglass Fabric Outer and Mica Inner Insulation | ||||||||||||
600V AC/600V DC | ||||||||||||
18 | 16/30 | 31 A @ 86° F | Not Rated | 1020° | 0.12" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
16 | 26/30 | 40 A @ 86° F | Not Rated | 1020° | 0.14" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 41/30 | 55 A @ 86° F | Not Rated | 1020° | 0.16" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
12 | 65/30 | 75 A @ 86° F | Not Rated | 1020° | 0.18" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
10 | 105/30 | 100 A @ 86° F | Not Rated | 1020° | 0.21" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
8 | 133/29 | 130 A @ 86° F | Not Rated | 1020° | 0.27" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 0000 | |
Stranded Wire with Fiberglass Fabric Outer and PTFE Plastic Inner Insulation | ||||||||||||
600V AC | ||||||||||||
18 | 19/30 | 12 A @ 86° F 4 A @ 400° F | -65° | 480° | 0.11" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
16 | 26/30 | 17 A @ 86° F 6 A @ 400° F | -65° | 480° | 0.12" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 41/30 | 12 A @ 400° F 35 A @ 86° F | -65° | 480° | 0.14" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
12 | 65/30 | 15 A @ 400° F 44 A @ 86° F | -65° | 480° | 0.16" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
10 | 105/30 | 21 A @ 400° F 61 A @ 86° F | -65° | 480° | 0.18" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000 | |
8 | 133/29 | 30 A @ 400° F 88 A @ 86° F | -65° | 480° | 0.23" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
6 | 133/27 | 114 A @ 86° F 39 A @ 400° F | -65° | 480° | 0.32" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Ceramic Fabric Outer and Mica Inner Insulation | ||||||||||||
300V AC | ||||||||||||
18 | 16/30 | 11 A @ 86° F 3 A @ 750° F | -40° | 1830° | 0.16" | Beige | __ | UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
16 | 26/30 | 14 A @ 86° F 4 A @ 750° F | -40° | 1830° | 0.17" | Beige | __ | UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
14 | 41/30 | 21 A @ 86° F 7 A @ 750° F | -40° | 1830° | 0.18" | Beige | __ | UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
12 | 65/30 | 26 A @ 86° F 8 A @ 750° F | -40° | 1830° | 0.2" | Beige | __ | UL 2556 VW-1 | 0000000 | 00000 | 0000 | |
10 | 105/30 | 11 A @ 750° F 35 A @ 86° F | -40° | 1830° | 0.23" | Beige | __ | UL 2556 VW-1 | 0000000 | 00000 | 0000 | |
8 | 168/30 | 43 A @ 86° F | -40° | 1830° | 0.29" | Beige | __ | UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Low-Voltage High-Temperature Wire
- Use for ovens and furnaces, panel and equipment (hook-up)
- Wire with FEP Plastic Insulation: Flexible
Wire with Silicone Rubber Insulation: Ultra Flexible - Temperature Range:
Wire with FEP Plastic Insulation: -239° to 390° F
Wire with Silicone Rubber Insulation: -100° to 400° F
Rated to 50 volts AC/DC, this wire is often used in small electronics and robotics. It’s also known as hook-up wire.
Wire with FEP insulation is chemical resistant.
Wire with silicone rubber insulation is ultra-flexible for use in applications that require tight turns. It also withstands moisture.
Silver-plated wire is stronger and more corrosion resistant than bare wire.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Strand Count | Current | OD | Wire Material | Choose an Outer Insulation Color | 10 ft. | 25 ft. | 50 ft. | |
Stranded Wire with FEP Plastic Insulation | |||||||||
---|---|---|---|---|---|---|---|---|---|
50V AC/50V DC | |||||||||
36 | 25/50 | 0.1 A @ 86° F | 0.01" | Silver-Plated Copper | 000000 | ||||
29 | 51/46 | 0.5 A @ 86° F | 0.02" | Silver-Plated Copper | 000000 | ||||
26 | 66/44 | 1 A @ 86° F | 0.02" | Silver-Plated Copper | 000000 | ||||
Stranded Wire with Silicone Rubber Insulation | |||||||||
50V AC/50V DC | |||||||||
36 | 25/50 | 0.1 A @ 86° F | 0.02" | Bare Copper | 000000 | ||||
29 | 51/46 | 0.5 A @ 86° F | 0.03" | Bare Copper | 000000 | ||||
26 | 66/44 | 1 A @ 86° F | 0.04" | Bare Copper | 000000 |
High-Temperature Wire Assortments
- Use For: Ovens and Furnaces, Panel and Equipment (Hook-Up)
- Ultra Flexible
- Temperature Range: -75° to 390° F
- Insulation: Silicone Rubber
Keep several colors of high-temperature wire on hand with these assortments. Silicone rubber insulation protects the wire from heat and moisture, and it is flexible enough to bend around tight turns. This wire is often used in ovens, furnaces, and other heating equipment—it’s also known as hook-up wire. Assortments come with one spool of each color listed.
High-Temperature Thin-Insulation Wire
- Use for ovens, furnaces, panel and equipment (hook-up),
- Flexible
- Temperature Range: -235° to 570° F
- Insulation: PFA Plastic
With a slim PFA plastic insulation, this wire has the same heat resistance as standard high-temperature wire but its diameter is one-third the size for use in tight spaces. It withstands water, sunlight, and chemicals, making it good for use in oil and gas applications. It’s also known as hook-up wire.
For technical drawings and 3-D models, click on a part number.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Specifications Met | Wire Material | Choose an Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||
600V AC | ||||||||||
28 | 7/36 | 1.4 A @ 86° F | 0.03" | UL Recognized Component | Nickel-Plated Copper | 0000000 | 00000 | 00000 | ||
26 | 19/38 | 1.8 A @ 86° F | 0.03" | UL Recognized Component | Nickel-Plated Copper | 0000000 | 0000 | 0000 | ||
24 | 19/36 | 3.5 A @ 86° F | 0.04" | UL Recognized Component | Nickel-Plated Copper | 0000000 | 0000 | 0000 | ||
22 | 19/34 | 5.3 A @ 86° F | 0.04" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 | ||
20 | 19/32 | 8.8 A @ 86° F | 0.05" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 | ||
18 | 19/30 | 12.4 A @ 86° F | 0.06" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 | ||
16 | 19/29 | 17.7 A @ 86° F | 0.07" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 |