About Wire and Cable
More
About Industry Designation for Cable Insulation
More
Cable
Use this general purpose cable to supply power to equipment.
For technical drawings and 3-D models, click on a part number.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 8 | 18/8 | 4 A @ 86° F | 0.53" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
16 | 8 | 16/8 | 7 A @ 86° F | 0.62" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 8 | 14/8 | 10.5 A @ 86° F | 0.81" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 000000 | 0000 | 00 |
Coiled Cable
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
Ultra-flexible cable extends and retracts more easily than flexible cable.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJOW and SOW have a multipurpose neoprene insulation.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
Miniature Cable
- Use For: Automation, Interference Shielding, Continuous Motion
- Continuous Flex
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Often used in computers, small electronics, and electronic prototyping, this cable is very flexible with small gauge wire to handle tight curves in narrow spaces. It withstands continuous motion, so it’s also commonly used around heavy vibration and in automated tasks, including robotics. A braid shield blocks interference from nearby equipment.
Direct-Burial Cable
- Use For: Buildings, Outdoors
- Flexible
- Temperature Range: 0° to 140° F
Weather-resistant insulation makes this cable suitable for outdoor use and direct burial without conduit.
18-gauge wire is often used for sprinkler systems.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Material | Inner Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | 500 ft. | |
30V AC/30V DC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18 | 8 | 18/8 | 0.29" | Black | Polypropylene Plastic | Black, Blue, Brown, Green, Orange, Red, White, Yellow | UL Listed | 0000000 |
Drop-Down Cable
Often used to wire pendant switches, this cable hangs from an overhead connection. It’s also known as bus drop cable.
The PVC insulation resists abrasion, chemicals, and oil.
Cable with strain relief has galvanized steel strain cables on the sides to provide strength and reduce the stress caused by equipment hanging from cable. Use the strain relief hardware (sold separately) to secure equipment to the cable.
- Use For: Drop-Down Power, Outdoors
- Flexible
- Temperature Range: 15° to 220° F
- Insulation: PVC Plastic
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
600V AC | |||||||||||
16 | 8 | 16/8 | 12 A @ 86° F | 0.52" | Yellow | Black, Blue, Blue/Black, Brown, Orange, Red, Red/Black, Yellow | UL Listed, C-UL Listed | 0000000 | 00000 | 00000 |
Strain Relief Hardware | 000000 | Each | 000000 |
High-Voltage Continuous-Flex Flat Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
12,000V DC/17,000V AC | |||||||||||||||
28 | 8 | 28/8 | 5 A @ 86° F | 0.43" | 0.08" | 0.8" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 | |
26 | 8 | 26/8 | 6 A @ 86° F | 0.46" | 0.09" | 0.9" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
24 | 8 | 24/8 | 8 A @ 86° F | 0.5" | 0.09" | 1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
18,000V DC/25,000V AC | |||||||||||||||
22 | 8 | 22/8 | 11 A @ 86° F | 0.59" | 0.11" | 1.1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
20 | 8 | 20/8 | 13 A @ 86° F | 0.67" | 0.12" | 1.2" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
20,000V DC/28,000V AC | |||||||||||||||
18 | 8 | 18/8 | 20 A @ 86° F | 0.81" | 0.14" | 1.4" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 0000 | |
16 | 8 | 16/8 | 26 A @ 86° F | 0.92" | 0.15" | 1.5" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Servomotor Continuous-Flex Cable
- Use For: Automation, Continuous Motion, Interference Shielding, Motors
- Continuous Flex
- Temperature Range: -40° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: Polypropylene Plastic
Connect servocontrollers and servomotors in automated equipment and on assembly lines. This cable withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion and oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Cable with signal wires is also known as feedback cable. It sends and receives signals between a servomotor and a PLC.
Cable with power and signal wires sends data such as positioning information from a servomotor to a controller. It has four power wires and two pairs of signal wires.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
No. of Wires | Wire Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Shielded—30V AC/45V DC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8 | 26 | 26/8 | 0.7 A @ 86° F | 0.25" | 2.17" | Green | Black, Blue, Brown, Green, Orange, Purple, Red, Yellow | UL Recognized Component, UL 2556 VW-1 | 0000000 | |||||
8 | 24 | 24/8 | 1.4 A @ 86° F | 0.29" | 1.87" | Green | Blue, Brown, Gray, Green, Pink, Red, White, Yellow | UL Recognized Component, UL 2556 VW-1 | 0000000 |
Power Wire | Signal Wire | Per Ft. | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-49 | 50-Up | |
Double Shielded—1,000V AC | ||||||||||||||||||
4 | 14 | 14/4 | 4 | 18 | 18/4 | __ | __ | __ | 15 A @ 86° F | 0.57" | 4.28" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, UL 2556 VW-1 | 0000000 | 000000 | 00000 | |
4 | 12 | 12/4 | 2 | 18 | 18/2 | 2 | 16 | 16/2 | 20 A @ 86° F | 0.64" | 4.8" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
4 | 10 | 10/4 | 2 | 18 | 18/2 | 2 | 16 | 16/2 | 30 A @ 86° F | 0.71" | 5.33" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Ethernet Cable
- Use For:
Unshielded: Data; Category 3 can also be used for Telephones
Shielded, Double Shielded: Data, Interference Shielding - Flexible
- Insulation:
Outer: PVC Plastic
Inner: See table
Send data between computers, printers, servers, and switches. Ethernet category standards describe the cable’s performance capabilities. Higher category numbers mean faster speeds, superior data transfer, and better signal strength. Category cables are backward compatible, so you can mix and match, but your speed will only be as fast as the lowest-rated cable.
Unshielded cable is the choice for day-to-day wiring, such as connecting your desktop computer to an ethernet port.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment, such as variable frequency drives or small motors. It has an uninsulated ground wire that is not counted in the number of wires.
Double-shielded cable has a layer of braid and foil shielding for the best protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and heavy duty motors.
CM and CMR cable prevent the spread of flames down the length of the cable. CMR is more flame resistant than CM cable.
Inner Insulation | Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Industry Designation | Material | Color | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||||
3 | 16 MHz | 24 | 8 | 24/8 | 140° | 0.16" | CMR | PVC Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Gray | 000000 | 00000 | 00000 | |
5E | 100 MHz | 24 | 8 | 24/8 | 165° | 0.21" | CM | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | 0000000 | 000 | 000 | ||
6 | 100 MHz | 23 | 8 | 23/8 | 165° | 0.22" | CMR | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | 0000000 | 000 | 000 | ||
Shielded Solid Wire with Uninsulated Ground Wire | ||||||||||||||
6 | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | CMR | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | 000000 | 000 | 000 | ||
Shielded Stranded Wire with Uninsulated Ground Wire | ||||||||||||||
5E | 100 MHz | 26 | 8 | 26/8 | 140° | 0.22" | CM | Polyethylene Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | White | 0000000 | 000 | 000 | |
Double-Shielded Solid Wire | ||||||||||||||
8 | 2,000 MHz | 23 | 8 | 23/8 | 165° | 0.32" | CM | Polyethylene Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Blue | 0000000 | 0000 | 0000 | |
Double-Shielded Stranded Wire | ||||||||||||||
6A | 500 MHz | 26 | 8 | 26/8 | 175° | 0.27" | __ | Polyethylene Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Yellow | 000000 | 0000 | 0000 |
Continuous-Flex Ethernet Cable
- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Outer Insulation: TPE Rubber, except Category 6A is Polyurethane Plastic
Inner Insulation: TPE Rubber, except Category 6A is Polyolefin Plastic
Often used in automated applications that require continuous motion such as robotics, this cable sends data between computers, servers, and switches without degrading data transmission. This Ethernet cable is backward compatible so it works in networks that meet the same or a lower category. It is double shielded, which means it has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors. Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Temp. Range, °F | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | ||||||||||||||
5E | 100 MHz | 26 | 8 | 26/8 | -30° to 155° | 0.33" | 3.3" | Purple | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | UL Recognized Component, C-UL Recognized Component, UL 2556 FT1 | 0000000 | 00000 | 00000 | |
6 | 250 MHz | 26 | 8 | 26/8 | -30° to 155° | 0.33" | 3.3" | Purple | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | UL Recognized Component, C-UL Recognized Component, UL 2556 FT1 | 0000000 | 00000 | 00000 | |
6A | 500 MHz | 26 | 8 | 26/8 | -40° to 155° | 0.28" | 4.2" | Green | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | UL Recognized Component, C-UL Recognized Component, CSA Certified, UL 2556 FT2 | 000000 | 0000 | 0000 |
Duct-Rated Ethernet Cable
- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Insulation:
Outer: PVC Plastic
Inner: See table
Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Inner Insulation Material | Inner Insulation Color | Features | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 165° | 0.21" | FEP/Polyolefin Plastic Blend | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | __ | 0000000 | 00000 | 00000 | ||
6 | 350 MHz | 23 | 8 | 23/8 | 165° | 0.23" | FEP/Polyolefin Plastic Blend | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | __ | 0000000 | 0000 | 000 | ||
Shielded Solid Wire | ||||||||||||||
6 | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | FEP Plastic | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | Uninsulated Ground Wire | Gray | 000000 | 0000 | 0000 |
Oil-Resistant Ethernet Cable
- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Max. Temperature: 165° F
- Insulation:
Inner Insulation: See table
Outer Insulation: PVC Plastic
From mines and factories to robotics, this rugged Ethernet cable sends data between sensors and switches in the grimiest places. The PVC outer insulation is treated to stand up to oil and coolants where typical PVC insulation would become brittle and crack. To make sure it doesn't kink and snap, this cable was tested under repeated bending and rubbing with little signs of wear. Higher numbers for the Ethernet category standard mean faster speeds, superior data transfer, and better signal strength. Category cables are backward compatible, so you can mix and match. However, your speed will only be as fast as the lowest-rated cable.
Choose unshielded cable for most applications. When working with variable frequency drives or small motors, choose shielded cable, which has a layer of foil that protects from signal interference. It has an uninsulated ground wire that is not counted in the number of wires.
Inner Insulation | Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | OD | Material | Color | Outer Insulation Color | Features | Length, ft. | 1-99 | 100-Up | |
Unshielded Solid Wire | |||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 0.23" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | __ | 000000 | 00000 | 00000 | |
6 | 600 MHz | 23 | 8 | 23/8 | 0.34" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | __ | 000000 | 0000 | 0000 | |
Shielded Solid Wire | |||||||||||||
5E | 100 MHz | 24 | 8 | 24/8 | 0.27" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | Uninsulated Ground Wire | 000000 | 0000 | 0000 | |
6 | 250 MHz | 23 | 8 | 23/8 | 0.27" | Polypropylene Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | Uninsulated Ground Wire | 00000000 | 0000 | 0000 |
Duct-Rated Oil-Resistant Ethernet Cable
- Use For: Data
- Flexible
- Max. Temperature: 300° F
- Insulation: FEP Plastic
Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Length, ft. | 1-99 | 100-Up | |
Solid Wire | |||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 0.19" | Black | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | 000000 | 00000 | 00000 | |
6 | 350 MHz | 23 | 8 | 23/8 | 0.21" | Black | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | 000000 | 0000 | 0000 |
Continuous-Flex Data Communication Cable
- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, it releases minimal particles into the air. It is CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | OD | Bend Radius | Outer Insulation Color | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire with PVC Plastic Insulation | |||||||||||
300V AC | |||||||||||
24 | 8 | 24/8 | 0.31" | 2.33" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
20 | 8 | 20/8 | 0.37" | 2.78" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
Shielded Stranded Wire with TPE Rubber Insulation | |||||||||||
300V AC | |||||||||||
24 | 8 | 24/8 | 0.35" | 2.24" | Blue | ISO Class 1 | CE Marked | 0000000 | 00000 | 0000 | |
20 | 8 | 20/8 | 0.39" | 2.52" | Blue | ISO Class 1 | CE Marked | 0000000 | 00000 | 00000 |
Data Communication Cable
- Use For: Data, Interference Shielding
- Flexible
- Outer Insulation: PVC Plastic
Connect computers, CNC machines, and other equipment that requires complex data and signal transmission. This double-shielded cable has both braid and foil for the highest level of protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and motors. This CM-designated cable is flame rated for general purpose applications, such as in-wall installation or use between equipment on shop floors. It’s also rated VW-1 to keep fire from spreading. This cable has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | Temp. Range, °F | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||||
300V AC | |||||||||||||||
24 | 8 | 24/8 | 10 | 12.5 pF | 0° to 165° | 0.28" | CM | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 00000 | 00000 |
Control Cable
- Use For:
Unshielded: Automation
Shielded: Automation; Interference Shielding - Flexible
- Temperature Range: 45° to 190° F
- Insulation: PVC Plastic
Send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. This cable is often used with conveyors, CNC machines, and to connect equipment to a control panel. The PVC insulation resists oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
For technical drawings and 3-D models, click on a part number.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 8 | 20/8 | 4 A @ 86° F | 0.34" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
16 | 8 | 16/8 | 12 A @ 86° F | 0.44" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 |
Flat Control Cable
- Use For: Automation
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Also known as festoon cable, this flat cable fits in confined spaces and withstands period flexing and bending, such as in overhead cranes and hoists. Use it to operate, measure, or regulate automated equipment. The PVC insulation resists oil and UV light. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | Per Ft. | |
Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
16 | 8 | 16/8 | 15 A @ 86° F | 1.11" | 0.2" | Yellow | Black, Blue, Blue/Black, Brown, Orange, Red, Red/Black, Yellow | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 00000 | |
14 | 8 | 14/8 | 25 A @ 86° F | 1.33" | 0.24" | Yellow | Black, Blue, Blue/Black, Brown, Orange, Red, Red/Black, Yellow | UL Listed, CSA Certified, UL 2556 VW-1 | 00000000 | 0000 | |
12 | 8 | 12/8 | 30 A @ 86° F | 1.34" | 0.23" | Yellow | Black, Blue, Blue/Black, Brown, Orange, Red, Red/Black, Yellow | UL Listed, CSA Certified, UL 2556 VW-1 | 00000000 | 0000 |
Flat Flexible Cable
- Temperature Range: -40° to 220° F
Made of thin, flattened wires, this flexible cable can be routed in tight spaces, such as inside a laptop. Connect it to your circuit board with flat flexible cable connectors (not included).
For technical drawings and 3-D models, click on a part number.
Riser-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 8 | 22/8 | 0.17" | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
22 | 8 | 22/8 | 0.19" | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 |
Duct-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 8 | 22/8 | 0.19" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | __ | CMP, CL3P | UL 13, UL 444 | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
22 | 8 | 22/8 | 0.19" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Temp. Range, °F | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Length, ft. | 1-99 | 100-Up | |
300V AC/300V DC | ||||||||||||
24 | 8 | 24/8 | 0° to 175° | 0.22" | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CM, CMG | 00000000 | 00000 | 00000 |
Thermostat Cable
- Use For: Buildings
- Bend and Stay
- Temperature Range: 0° to 140° F
- Insulation:
Outer: PVC Plastic
Inner: Polyethylene Plastic
Hook up thermostats, air-conditioning units, and other low-voltage equipment. This cable is designated CL2 so it has flame-resistant insulation. The wires are solid so it stays in the shape you bend it.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
150V AC/150V DC | |||||||||||||
20 | 8 | 20/8 | 0.17" | Brown | Black, Blue, Brown, Green, Orange, Red, White, Yellow | CL2 | ETL Listed | 0000000 | |||||
18 | 8 | 18/8 | 0.2" | Brown | Black, Blue, Brown, Green, Orange, Red, White, Yellow | CL2 | ETL Listed | 0000000 |
Shielded Micro M12 Screw-Together Connectors
Block signal interference from nearby devices, such as motors and transmitters, while maintaining a strong, stable connection for M12 threads. The shielding on these connectors maintains signal integrity and minimizes signal loss between equipment. The threaded housing creates a secure connection that withstands the shaking and vibrating of industrial automation.
A-coded, these connectors are often used to connect equipment to IO Link controllers and devices within Profibus, DeviceNet, and other fieldbus systems. They work with both AC and DC devices such as sensors, motors, and light curtains. Poles and keyways on their face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
Connectors with polyurethane outer insulation are halogen free, so they won’t release toxic fumes or cause corrosion in metal. Polyurethane resists chemicals, oil, and UV rays, and is very flexible. It’s good for use in industrial environments and robotics.
All meet IP ratings when either mated or capped. IP66K rated connectors are dust tight and protected from washdowns. IP67 rated connectors are protected from dust and temporary submersion.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: They may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.
Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 000000 |
16 ft. Cable Lead Lg. | |||||||||||||||
8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 00000 |
Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 000000 |
16 ft. Cable Lead Lg. | |||||||||||||||
8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 000000 |
For Thread Size | Material | Each | |
For Sockets with Internal Threads | |||
---|---|---|---|
M12 | Anodized Aluminum | 0000000 | 000000 |
Screw-Together Wet-Location RJ45 Connectors and Cords
Use these connectors and cords to make Ethernet connections.
IP67 rated connectors and cords are protected against dust and temporary submersion when mated.
NEMA 6 rated connectors and cords are protected against dust, washdowns, and temporary submersion.
Shielded adapters prevent electromagnetic interference (EMI) to minimize signal distortion.
Sockets with a 110 punch-down wire connection require a punch-down tool to terminate (not included).
Plugs with a crimp-on wire connection require an Ethernet cable crimper to terminate (not included).
Caps (sold separately) protect sockets and maintain the IP rating when not in use.
For technical drawings and 3-D models, click on a part number.
For Wire Type | For Cable OD | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Unshielded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Solid | 0.1"-0.26" | Category 5E | 100 MHz | 8 | Black | Plastic | IP67 | 0° to 175° | 0000000 | 000000 |
For Panel Cutout Dia. | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Unshielded | |||||||||
---|---|---|---|---|---|---|---|---|---|
1" | Category 5E | 100 MHz | 8 | Black | Plastic | IP67, NEMA 6 | 0° to 175° | 0000000 | 000000 |
For Panel Cutout Dia. | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Unshielded | |||||||||
---|---|---|---|---|---|---|---|---|---|
40mm | Category 5E | 100 MHz | 8 | Black | Plastic | IP67 | 0° to 175° | 0000000 | 000000 |
Ethernet Connection Type | For Panel Cutout Dia. | Shield Type | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Shielded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
RJ45 | 1" | Foil | Category 5E | 100 MHz | 8 | Black | Plastic | IP67 | 0° to 175° | 0000000 | 000000 |
1 ft. Lg. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Cord OD | Flexibility | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Unshielded | |||||||||||
26 | 0.25" | Flexible | Category 5E | 100 MHz | 8 | Black | Plastic | IP67 | 0° to 175° | 0000000 | 000000 |
Micro M12 Screw-Together Ethernet Connectors
Unlike traditional RJ45 connectors found in data centers, these connectors stand up to rugged industrial environments since they tightly thread to devices with M12 connections, sealing out contaminants and resisting shaking loose from vibration. Use them to transfer high-speed data between sensors, switches, computers, IO modules, programmable logic controllers (PLCs), and other equipment. They can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. These connectors are often used with EtherNet/IP, Profinet, and EtherCAT systems. Since they’re shielded, they block signal interference from nearby devices, maintaining their speed and data integrity. Poles and keyways on the face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
When choosing an Ethernet connector, make sure you match or exceed your network’s category industry designation. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
A-coded and X-coded connectors send data faster than D-coded connectors, so they’re best for robotics and other systems that run multi-step programs.
Receptacles thread into a panel or wall, making them best for permanent installations such as control panels or hardwiring into equipment.
90° elbow connectors run your cord along the side of equipment, so they fit behind machines and in tight spaces.
Connectors with polyurethane or TPE insulation resist chemicals, oil, and sunlight for outdoor use. Because they’re flexible, they’re good for jobs with continuous motion, such as robotics.
IP rated connectors keep out dust and can be used in wet areas when mated or capped. IP67 connectors can be submerged temporarily.
Add caps to protect connectors and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.
Housing Thread | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
3 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 0000000 | 000000 |
X-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 0000000 | 00000 |
16 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 0000000 | 000000 |
X-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 0000000 | 00000 |
Housing Thread | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Each | |
3 ft. Lg. Cable Leads | ||||||||||||
X-Code | ||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 0000000 | 000000 |
16 ft. Lg. Cable Leads | ||||||||||||
X-Code | ||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 0000000 | 00000 |
Housing Thread | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
3 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 0000000 | 000000 |
X-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 0000000 | 00000 |
16 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 0000000 | 000000 |
X-Code | |||||||||||||
8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 0000000 | 000000 |
Housing Thread | Mounting | 1ft. Lg. Wire Leads | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Wire Lead Gauge (No. of Wires) | Wire Insulation Material | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Pipe Size | Thread Type | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
A-Code | |||||||||||||||
8 | 24 (8) | PVC Plastic | Not Rated | Gray | Anodized Aluminum | M12 | 1 | 0.875" | 1/2 | NPT | -40° to 175° | IP67 | UL Listed, C-UL Listed | 0000000 | 000000 |
Housing Thread | Mounting | 1ft. Lg. Wire Leads | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Wire Lead Gauge (No. of Wires) | Wire Insulation Material | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Pipe Size | Thread Type | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
A-Code | |||||||||||||||