About Wire and Cable
More
About Industry Designation for Cable Insulation
More
Cable
Use this general purpose cable to supply power to equipment.
For technical drawings and 3-D models, click on a part number.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 6 | 18/6 | 5 A @ 86° F | 0.5" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
16 | 6 | 16/6 | 8 A @ 86° F | 0.52" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 6 | 14/6 | 12 A @ 86° F | 0.71" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 000000 | 0000 | 00 | |
Per Ft. | |||||||||||
1-249 | 250-Up | ||||||||||
12 | 6 | 12/6 | 16 A @ 86° F | 0.74" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 6 | 10/6 | 20 A @ 86° F | 0.88" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 0000 |
Coiled Cable
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
Ultra-flexible cable extends and retracts more easily than flexible cable.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJOW and SOW have a multipurpose neoprene insulation. SJEOW and SEOW have a TPE rubber insulation that also withstands chemicals.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
300V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16 | 6 | 16/6 | 7 A @ 86° F | 0.46" | 1.67" | Black | Black, Blue, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
600V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16 | 6 | 16/6 | 7 A @ 86° F | 0.58" | 2" | Black | Black, Blue, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 |
Abrasion-Resistant Cable
- Use For:
Unshielded: Motors, Power Supply
Shielded: Motors, Power Supply, Interference Shielding - Flexible
- Temperature Range: -20° to 190° F
- Insulation:
Outer: Polyurethane Rubber
Inner: PVC Plastic
A thick insulation resists cuts and abrasion, so this cable can be pulled over rough surfaces without damaging the wires inside. Made of polyurethane rubber, the insulation also resists chemicals, moisture, oil, solvents, and water. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
300V AC | ||||||||||||
18 | 6 | 18/6 | 6.3 A @ 86° F | 0.31" | Black | Black, Blue, Green, Orange, Red, White | __ | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 000000 | 000000 | |
Shielded Stranded Wire | ||||||||||||
300V AC | ||||||||||||
22 | 6 | 22/6 | 2.7 A @ 86° F | 0.22" | Black | Black, Brown, Green, Orange, Red, Yellow | Uninsulated Ground Wire | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 0000 |
Miniature Cable
- Use For: Automation, Interference Shielding, Continuous Motion
- Continuous Flex
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Often used in computers, small electronics, and electronic prototyping, this cable is very flexible with small gauge wire to handle tight curves in narrow spaces. It withstands continuous motion, so it’s also commonly used around heavy vibration and in automated tasks, including robotics. A braid shield blocks interference from nearby equipment.
Direct-Burial Cable
- Use For: Buildings, Outdoors
- Flexible
- Temperature Range: 0° to 140° F
Weather-resistant insulation makes this cable suitable for outdoor use and direct burial without conduit.
18-gauge wire is often used for sprinkler systems.
Continuous-Flex Cable
Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
24 | 6 | 24/6 | 5 A @ 86° F | 0.24" | 1.8" | Gray | Brown, Gray, Green, Pink, White, Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 |
High-Voltage Continuous-Flex Flat Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
12,000V DC/17,000V AC | |||||||||||||||
28 | 6 | 28/6 | 5 A @ 86° F | 0.33" | 0.08" | 0.8" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 | |
26 | 6 | 26/6 | 6 A @ 86° F | 0.35" | 0.09" | 0.9" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
24 | 6 | 24/6 | 8 A @ 86° F | 0.38" | 0.09" | 1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
18,000V DC/25,000V AC | |||||||||||||||
22 | 6 | 22/6 | 11 A @ 86° F | 0.45" | 0.11" | 1.1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
20 | 6 | 20/6 | 13 A @ 86° F | 0.51" | 0.12" | 1.2" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
20,000V DC/28,000V AC | |||||||||||||||
18 | 6 | 18/6 | 20 A @ 86° F | 0.62" | 0.14" | 1.4" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
16 | 6 | 16/6 | 26 A @ 86° F | 0.7" | 0.15" | 1.5" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Continuous-Flex Data Communication Cable
- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, it releases minimal particles into the air. It is CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | OD | Bend Radius | Outer Insulation Color | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire with PVC Plastic Insulation | |||||||||||
300V AC | |||||||||||
24 | 6 | 24/6 | 0.28" | 2.1" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
22 | 6 | 22/6 | 0.31" | 2.33" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 00000000 | 0000 | 0000 | |
20 | 6 | 20/6 | 0.35" | 2.63" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
Shielded Stranded Wire with TPE Rubber Insulation | |||||||||||
300V AC | |||||||||||
24 | 6 | 24/6 | 0.32" | 2.11" | Blue | ISO Class 1 | CE Marked | 0000000 | 0000 | 0000 |
Data Communication Cable
- Use For: Data, Interference Shielding
- Flexible
- Outer Insulation: PVC Plastic
Connect computers, CNC machines, and other equipment that requires complex data and signal transmission. This double-shielded cable has both braid and foil for the highest level of protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and motors. This CM-designated cable is flame rated for general purpose applications, such as in-wall installation or use between equipment on shop floors. It’s also rated VW-1 to keep fire from spreading. This cable has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | Temp. Range, °F | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||||
300V AC | |||||||||||||||
24 | 6 | 24/6 | 10 | 12.5 pF | 0° to 165° | 0.27" | CM | Gray | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 00000 | 00000 |
Twisted-Pair Data Communication Cable
- Use For: Data, Interference Shielding
- Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
This cable has twisted pairs of wires that cancel signal interference from multiple transmission lines, as well as foil and braid shielding over the entire cable. It's often used to transmit data in high speed computers near variable-frequency drive motors, where voltage fluctuations and current spikes can distort signals. The industry designation is CM and CMG, so it’s approved for in-wall installation and has flame-resistant insulation. The uninsulated ground wire is not counted in the number of wires.
Telephone Cable
- Use For: Telephones
- Flexible
Connect telephones and telephone blocks to a wall jack. Terminate the cable with telephone plugs or jacks (not included).
Variable-Frequency Drive Motor Cable
This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power and signal wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.
- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Inner Insulation: Polyethylene Plastic
Power Wire | Signal Wire | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Features | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Double Shielded—1,000V AC/1,000V DC | |||||||||||||||||
4 | 16 | 16/4 | 2 | 18 | 18/2 | 18 A @ 86° F | 0.57" | Black | Black, Green/Yellow | WTTC | Uninsulated Ground Wire | 00000000 | |||||
4 | 14 | 14/4 | 2 | 18 | 18/2 | 25 A @ 86° F | 0.62" | Black | Black, Green/Yellow | WTTC | Uninsulated Ground Wire | 0000000 | |||||
4 | 12 | 12/4 | 2 | 18 | 18/2 | 30 A @ 86° F | 0.65" | Black | Black, Green/Yellow | WTTC | Uninsulated Ground Wire | 0000000 |
Flat Flexible Cable
- Temperature Range: -40° to 220° F
Made of thin, flattened wires, this flexible cable can be routed in tight spaces, such as inside a laptop. Connect it to your circuit board with flat flexible cable connectors (not included).
For technical drawings and 3-D models, click on a part number.
Riser-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 6 | 22/6 | 0.16" | Gray | Black, Blue, Brown, Green, Red, White | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.21" | Gray | Black, Blue, Brown, Green, Red, White | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
18 | 6 | 18/6 | 0.23" | Gray | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 |
Duct-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 6 | 22/6 | 0.16" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.21" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
18 | 6 | 18/6 | 0.23" | White | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
Coiled Communication Cable
- Use For: Buildings, Outdoors
- Flexibility: See Table
- Temperature Range: -40° to 140° F
- Insulation: Neoprene Rubber
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with microphones, headsets, and other types of low-circuit communication equipment.
Use unshielded cable in applications where signal interference isn’t a concern.
Thermostat Cable
- Use For: Buildings
- Bend and Stay
- Temperature Range: 0° to 140° F
- Insulation:
Outer: PVC Plastic
Inner: Polyethylene Plastic
Hook up thermostats, air-conditioning units, and other low-voltage equipment. This cable is designated CL2 so it has flame-resistant insulation. The wires are solid so it stays in the shape you bend it.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
150V AC/150V DC | |||||||||||||
20 | 6 | 20/6 | 0.16" | Brown | Blue, Brown, Green, Red, White, Yellow | CL2 | ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.19" | Brown | Blue, Brown, Green, Red, White, Yellow | CL2 | ETL Listed | 0000000 |
Access Control Cable
- Use For: Buildings
- Flexible
- Temperature Range: 32° to 165° F
- Insulation: PVC Plastic
Wire multiple components in your security system using a single cable. This cable bundles together four color-coded cables that correspond to each part of an access point: the card reader, the door contact, the lock, and the exit sign. Each interior cable is labeled with the component it matches. All four interior cables have a layer of foil around them to prevent signal interference from nearby devices. Designated CMP, it has a flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. It’s also known as plenum cable. It’s rated FT6, so it meets requirements for preventing the spread of flames and smoke based on a timed test with material mounted to a horizontal tray.
For technical drawings and 3-D models, click on a part number.
Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Application | Ga. | No. of | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 25 ft. Lg. | 50 ft. Lg. | 100 ft. Lg. | 200 ft. Lg. | |
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
Card Reader Door Contact Exit Sign Lock | 22 22 22 18 | 6 2 4 4 | 22/6 22/2 22/4 18/4 | 2.2 A @ 86° F 2.2 A @ 86° F 2.2 A @ 86° F 4 A @ 86° F | 0.46" | Yellow | Blue, Gray, Orange, White | CMP | Flame Rated FT6 | 0000000 |