About Wire and Cable
More
Continuous-Flex Cable
Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
20 | 18 | 20/18 | 10 A @ 86° F | 0.47" | 3.53" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
18 | 18 | 18/18 | 13 A @ 86° F | 0.53" | 3.98" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 19 A @ 86° F | 0.69" | 5.18" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 0000 | |
600V AC | ||||||||||||||
22 | 18 | 22/18 | 4 A @ 86° F | 0.47" | 3.2" | Green | Black, Blue, Blue/Red, Brown, Brown/Gray, Brown/Green, Gray, Gray/White, Green, Green/White, Pink, Pink/Gray, Purple, Red, White, Yellow, Yellow/Brown, Yellow/White | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
20 | 18 | 20/18 | 4 A @ 86° F | 0.49" | 3.47" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
18 | 18 | 18/18 | 6 A @ 86° F | 0.59" | 4.01" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.75" | 5.24" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
14 | 18 | 14/18 | 13 A @ 86° F | 1.08" | 6.32" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
- Use For: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
20 | 18 | 20/18 | 5 A @ 86° F | 0.57" | 4.28" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.61" | 4.58" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 11 A @ 86° F | 0.75" | 5.63" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
600V AC | ||||||||||||||
20 | 18 | 20/18 | 8 A @ 86° F | 0.59" | 4.01" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
18 | 18 | 18/18 | 12 A @ 86° F | 0.69" | 4.69" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
16 | 18 | 16/18 | 18 A @ 86° F | 0.83" | 5.64" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Oil-Resistant Continuous-Flex Cable
This cable has an insulation with excellent resistance to oil, so it can be used near motors and equipment that require oil lubrication. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Insulation:
300 and 1000V AC: TPE Rubber Inner Insulation
600V AC: PVC Plastic Inner Insulation
See Table for Outer Insulation - Environment:
300 and 1000V AC: Clean Room
600V AC: Not Rated - Specifications Met:
300 and 1000V AC: UL Recognized Component, C-UL Recognized Component, Flame Rated VW-1
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
20 | 18 | 20/18 | 3 A @ 86° F | 45° to 190° | 0.47" | 3.53" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 000000 | 000000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 45° to 190° | 0.54" | 4.05" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 45° to 190° | 0.61" | 4.58" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
14 | 18 | 14/18 | 12 A @ 86° F | 45° to 190° | 0.82" | 6.15" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
1,000V AC | ||||||||||||||
24 | 18 | 24/18 | 3 A @ 86° F | -30° to 175° | 0.41" | 2.79" | Polyurethane Rubber | Gray | Black, Red, Blue, Brown, Gray, Green, Pink, Purple, White, Yellow, Blue/Red, Brown/Gray, Brown/Green, Gray/White, Green/White, Pink/Gray, Yellow/Brown, Yellow/White | ISO Class 1 | 0000000 | 0000 | 0000 | |
20 | 18 | 20/18 | 5 A @ 86° F | -30° to 175° | 0.47" | 3.2" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 0000 | 0000 | |
18 | 18 | 18/18 | 7 A @ 86° F | -30° to 175° | 0.53" | 3.6" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 11 A @ 86° F | -30° to 175° | 0.67" | 4.56" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 |
- Use For: Shielded: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Insulation:
600V AC: PVC Plastic Inner Insulation
1,000V AC: TPE Rubber Inner Insulation
See Table for Outer Insulaton - Environment:
600V AC: Not Rated
1,000V AC: Clean Room - Specifications Met:
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
1,000V AC: UL Recognized Component, C-UL Recognized Component, Flame-Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
18 | 18 | 18/18 | 7 A @ 86° F | 45° to 190° | 0.67" | 5.03" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 000000 | 000000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 45° to 190° | 0.74" | 5.55" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
1,000V AC | ||||||||||||||
20 | 18 | 20/18 | 5 A @ 86° F | -30° to 175° | 0.57" | 3.88" | Polyurethane Rubber, TPE Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 | |
18 | 18 | 18/18 | 7 A @ 86° F | -30° to 175° | 0.61" | 4.15" | Polyurethane Rubber, TPE Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 | |
16 | 18 | 16/18 | 11 A @ 86° F | -30° to 175° | 0.75" | 5.1" | Polyurethane Rubber, TPE Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 |
No-Conduit-Required Continuous-Flex Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range: 25° to 175° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic, PVC Plastic
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
20 | 18 | 20/18 | 4 A @ 86° F | 0.55" | 4.4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 000000 | 000000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.58" | 4.64" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.65" | 1.68" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
20 | 18 | 20/18 | 4 A @ 86° F | 0.64" | 6.3" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.66" | 6.6" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.73" | 7.2" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 |
Continuous-Flex and -Twist Robotics Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range:
300V AC, 600V AC: -40° to 175° F
1,000V AC: -10° to 175° F - Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
In addition to handling continuous movement, this cable withstands twisting up to 450° without degrading data or signal transmission. It's often used in welding robots and rotary tables. It’s flame rated VW-1 to meet requirements for preventing the spread of flame based on a timed test with vertically suspended material. The polyurethane rubber insulation resists abrasion and oil.
Use unshielded cable in applications where signal interference is not a concern.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 18 | 18/18 | 7 A @ 86° F | 0.59" | 7.08" | Black | Black, Green/Yellow | CSA Certified, UL Recognized Component, UL 2556 VW-1 | 0000000 | 000000 | 000000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.67" | 8.04" | Black | Black, Green/Yellow | CSA Certified, UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Long-Life Continuous-Flex Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -30° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
With a life span of more than 20 million high-speed flex cycles, this cable lasts twice as long as standard continuous-flex cable so you have to replace cable less frequently. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion, chemicals, and oil.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Control Cable
- Use For:
Unshielded: Automation
Shielded: Automation; Interference Shielding - Flexible
- Temperature Range: 45° to 190° F
- Insulation: PVC Plastic
Send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. This cable is often used with conveyors, CNC machines, and to connect equipment to a control panel. The PVC insulation resists oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 18 | 20/18 | 3 A @ 86° F | 0.45" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.54" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.6" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 18 | 14/18 | 12 A @ 86° F | 0.74" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire | |||||||||||
600V AC | |||||||||||
18 | 18 | 18/18 | 7 A @ 86° F | 0.63" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.71" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 |
No-Conduit-Required Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands periodic flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 18 | 18/18 | 7 A @ 86° F | 0.59" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 00000 | 00000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.65" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 | |
Double-Shielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 18 | 18/18 | 7 A @ 86° F | 0.62" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.68" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 |