About Wire and Cable
More
About Industry Designation for Cable Insulation
More
Cable

Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
High-Voltage Cable

- Use For: Power Supply, Outdoors
- Flexible
- Temperature Range: -40° to 190° F
- Insulation: EPDM Rubber
Often used in mining equipment, submersible pumps, and drilling rigs, this cable withstands 2,000 volts AC/DC. The EPDM insulation resists abrasion, so it can be pulled over rough surfaces without damaging the wires inside.
For technical drawings and 3-D models, click on a part number.
No-Conduit-Required Control Cable

- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands periodic flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
For technical drawings and 3-D models, click on a part number.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
6 | 3 | 6/3 | 75 A @ 86° F | 0.78" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 000000 | 000000 |
Power Cords


Connect equipment and devices to a power supply.
Cords with a NEMA 14-30 or 14-50 plug are often used to power electric vehicles. They have a high current rating.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
The insulation on STW and SJTW cords resists water.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
90° Elbow NEMA 14-50 Plug × Wire Leads | |||||||||||
8, 6 | 50 | 125V AC/250V AC | 4 | 1.08" | PVC Plastic | STW | 0° to 140° | UL Listed | Black | 000000000 | 000000 |
8, 6 | 50 | 125V AC/250V AC | 30 | 1.08" | PVC Plastic | STW | 0° to 140° | UL Listed | Black | 000000000 | 000000 |
8, 6 | 50 | 125V AC/250V AC | 36 | 1.08" | PVC Plastic | STW | 0° to 140° | UL Listed | Black | 000000000 | 000000 |