About Wire and Cable
More
High-Temperature Cable
The insulation on this cable withstands high-heat applications such as ovens and furnaces. The wires are silver or nickel plated for corrosion resistance.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. It has PTFE outer and inner insulation that resists chemicals, oil, abrasion, and moisture.
- Use For: Ovens and Furnaces, Interference Shielding
- Flexible
- Temperature Range: -65° to 390° F
- Insulation: PTFE Plastic
Abrasion-Resistant Cable
- Use For:
Unshielded: Motors, Power Supply
Shielded: Motors, Power Supply, Interference Shielding - Flexible
- Temperature Range: -20° to 190° F
- Insulation:
Outer: Polyurethane Rubber
Inner: PVC Plastic
A thick insulation resists cuts and abrasion, so this cable can be pulled over rough surfaces without damaging the wires inside. Made of polyurethane rubber, the insulation also resists chemicals, moisture, oil, solvents, and water. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Low-Voltage Cable
- Use For: Appliances, Vehicles
- Flexible
- Temperature Range: -40° to 175° F
- Insulation: PVC Plastic
Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
For technical drawings and 3-D models, click on a part number.
Continuous-Flex Cable
Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
22 | 2 | 22/2 | 7 A @ 86° F | 0.2" | 1.5" | Gray | Brown, White | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 |
High-Voltage Continuous-Flex Flat Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
18,000V DC/25,000V AC | |||||||||||||||
22 | 2 | 22/2 | 11 A @ 86° F | 0.18" | 0.11" | 1.1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Continuous-Flex and -Twist Robotics Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range:
300V AC, 600V AC: -40° to 175° F
1,000V AC: -10° to 175° F - Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
In addition to handling continuous movement, this cable withstands twisting up to 450° without degrading data or signal transmission. It's often used in welding robots and rotary tables. It’s flame rated VW-1 to meet requirements for preventing the spread of flame based on a timed test with vertically suspended material. The polyurethane rubber insulation resists abrasion and oil.
Use unshielded cable in applications where signal interference is not a concern.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Industrial Communication-Standard Cable
- Use For:
Flexible: Data, Interference Shielding
Continuous Flex: Data, Interference Shielding, Automation, Continuous Motion - Insulation: See Table
Connect devices such as sensors, programmable logic controllers, and actuators to an automated network. Choose the communication standard that matches your existing network.
Flexible cable bends easily, but is not meant to be in constant motion. Use continuous-flex cable in automated applications that require continuous motion, such as robotics.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Its protective layer resists abrasion, though it contains halogen. It’s also less flexible than cable with TPE rubber insulation. Cable with TPE rubber outer insulation has a halogen-free protective layer that is more flexible and resists abrasion better than other materials. It also stands up to extreme temperatures and chemicals, making it good for use in harsh outdoor environments.
Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Uninsulated ground wires are not counted in the number of wires.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT4 cable is mounted to a vertical tray during testing. VW-1 cable is suspended vertically during testing.
Outer Insulation | Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Standard | Transmission Speed | Wire Ga. (No. of Wires) | Temp. Range, °F | OD | Material | Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Flexible | ||||||||||||
Double-Shielded Solid Wire | ||||||||||||
Profibus | 12 Mbps | 22 (2) | -20° to 165° | 0.32" | PVC Plastic | Purple | __ | UL 2556 FT4 | 000000 | 00000 | 00000 | |
Double-Shielded Stranded Wire | ||||||||||||
Devicenet | 500 kbps | (4) total: 24 (2), 22 (2) | 0° to 165° | 0.28" | PVC Plastic | Gray | Uninsulated Ground Wire | UL 2556 FT4 | 000000 | 0000 | 0000 | |
Continuous Flex | ||||||||||||
Double-Shielded Stranded Wire | ||||||||||||
Devicenet | 125 kbps | (4) total: 24 (2), 22 (2) | -30° to 155° | 0.3" | TPE Rubber | Purple | __ | UL 2556 VW-1 | 000000 | 0000 | 0000 |
Audio Cable
- Use For: Audio, Buildings
- Flexible
- Temperature Range: See table
- Outer Insulation Material: PVC Plastic
Hook up speakers, intercoms, and other low-current devices to a building's communication wiring. This CL2 cable is suitable for in-wall installation in single-level facilities. The wires can be separated for installation. All cable has one wire marked for polarity, except for 0.17-in.-wide cable.
Riser-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Use unshielded cable in applications where signal interference is not a concern.
- Use For: Buildings
- Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
Duct-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.11" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.14" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 |
Access Control Cable
- Use For: Buildings
- Flexible
- Temperature Range: 32° to 165° F
- Insulation: PVC Plastic
Wire multiple components in your security system using a single cable. This cable bundles together four color-coded cables that correspond to each part of an access point: the card reader, the door contact, the lock, and the exit sign. Each interior cable is labeled with the component it matches. All four interior cables have a layer of foil around them to prevent signal interference from nearby devices. Designated CMP, it has a flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. It’s also known as plenum cable. It’s rated FT6, so it meets requirements for preventing the spread of flames and smoke based on a timed test with material mounted to a horizontal tray.
For technical drawings and 3-D models, click on a part number.
Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Application | Ga. | No. of | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 25 ft. Lg. | 50 ft. Lg. | 100 ft. Lg. | 200 ft. Lg. | |
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
Card Reader Door Contact Exit Sign Lock | 22 22 22 18 | 6 2 4 4 | 22/6 22/2 22/4 18/4 | 2.2 A @ 86° F 2.2 A @ 86° F 2.2 A @ 86° F 4 A @ 86° F | 0.46" | Yellow | Blue, Gray, Orange, White | CMP | Flame Rated FT6 | 0000000 |