Cable
Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
SJTW cable has a water-resistant outer insulation.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Orange Outer Insulation | ||||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | -40° to 165° | 0.35" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: -40° to 165° F
- Insulation: PVC Plastic
STOW cable has an oil- and water-resistant outer insulation.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -40° to 220° F
Yellow: -55° to 220° F - Insulation: TPE Rubber
SJEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | 0.36" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | 0.37" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | ||||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | -40° to 220° | 0.52" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | ||||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | -75° to 220° | 0.52" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- EPDM Rubber Outer Insulation: Ultra Flexible
Chlorinated Polyethylene Plastic Outer Insulation: Flexible - Temperature Range: See table
- Insulation:
Outer: See table
Inner: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SJOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The outer insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Outer Insulation Material | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | -40° to 190° | 0.37" | EPDM Rubber | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | -55° to 220° | 0.38" | EPDM Rubber | Black, Green/Yellow, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | 0.54" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
14 | 3 | 14/3 | 18 A @ 86° F | 0.53" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 |
Coiled Cable
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
Ultra-flexible cable extends and retracts more easily than flexible cable.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJOW and SOW have a multipurpose neoprene insulation. SJEOW and SEOW have a TPE rubber insulation that also withstands chemicals.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
600V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
14 | 3 | 14/3 | 18 A @ 86° F | 0.57" | 2.4" | Black | Black, Green, White | UL Listed, CSA Certified | 0000000 |
High-Temperature Cable
The insulation on this cable withstands high-heat applications such as ovens and furnaces. The wires are silver or nickel plated for corrosion resistance.
Use unshielded cable in applications where signal interference is not a concern. It has a layer of fiberglass fabric and mica tape around each wire. The entire cable is wrapped in a layer of fiberglass fabric and mica tape, and then covered in PTFE. The PTFE outer insulation resists chemicals, oil, abrasion, and moisture.
- Use For: Ovens and Furnaces
- Flexible
- Temperature Range: -40° to 840° F
- Insulation:
Outer: Fiberglass Fabric, Mica, PTFE Plastic
Inner: Fiberglass Fabric, Mica
Corrosion-Resistant Cable
- Use For: Boats, Motors, Panel and Equipment (Hook-Up), Power Supply
- Flexible
- Temperature Range: -40° to 230° F
- Insulation:
Outer: Chlorinated Polyethylene Plastic
Inner: See table
The chlorinated polyethylene insulation resists corrosive chemicals and salt water, and the wires are tin plated for corrosion resistance. This cable also withstands oil and solvents. It’s rated UL 1309 for use as marine shipboard cable.
Cable with braided bronze armor has excellent protection against abrasion and other damage.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with Polyolefin Plastic Inner Insulation | |||||||||||
600V AC | |||||||||||
14 | 3 | 14/3 | 20 A @ 86° F | 0.4" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Polyolefin Plastic, Braided Bronze Armor Inner Insulation | |||||||||||
600V AC | |||||||||||
14 | 3 | 14/3 | 20 A @ 86° F | 0.58" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 0000 | 0000 |
Continuous-Flex Cable
Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
14 | 3 | 14/3 | 27 A @ 86° F | 0.33" | 2.48" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 |
- Use For: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
14 | 3 | 14/3 | 30 A @ 86° F | 0.41" | 3.08" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 |
Oil-Resistant Continuous-Flex Cable
This cable has an insulation with excellent resistance to oil, so it can be used near motors and equipment that require oil lubrication. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Insulation:
300 and 1000V AC: TPE Rubber Inner Insulation
600V AC: PVC Plastic Inner Insulation
See Table for Outer Insulation - Environment:
300 and 1000V AC: Clean Room
600V AC: Not Rated - Specifications Met:
300 and 1000V AC: UL Recognized Component, C-UL Recognized Component, Flame Rated VW-1
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
14 | 3 | 14/3 | 25 A @ 86° F | 45° to 190° | 0.37" | 2.78" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
1,000V AC | ||||||||||||||
14 | 3 | 14/3 | 30 A @ 86° F | -30° to 175° | 0.33" | 2.24" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 0000 | 0000 |
Continuous-Flex and -Twist Robotics Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range:
300V AC, 600V AC: -40° to 175° F
1,000V AC: -10° to 175° F - Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
In addition to handling continuous movement, this cable withstands twisting up to 450° without degrading data or signal transmission. It's often used in welding robots and rotary tables. It’s flame rated VW-1 to meet requirements for preventing the spread of flame based on a timed test with vertically suspended material. The polyurethane rubber insulation resists abrasion and oil.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||||
600V AC | ||||||||||||||
14 | 3 | 14/3 | 25 A @ 86° F | 0.41" | 4.92" | Black | Black, Green/Yellow | __ | __ | CSA Certified, UL Recognized Component, UL 2556 VW-1 | 0000000 | 000000 | 00000 | |
Shielded Stranded Wire | ||||||||||||||
1,000V AC | ||||||||||||||
14 | 3 | 14/3 | 30 A @ 86° F | 0.37" | 3.9" | Blue | Black, Green/Yellow | Clean Room | ISO Class 1 | C-UL Recognized Component, UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 |
High-Temperature Continuous-Flex Cable
- Use For: Automation, Continuous Motion, Ovens and Furnaces
- Continuous Flex
- Temperature Range: -10° to 350° F
- Insulation:
Outer: Silicone Rubber
Inner: FEP Plastic
Bend and flex this silicone-insulated cable in temperatures up to 350° F. It can keep moving in areas twice as hot as most other continuous-flex cables without degrading data or signal transmission. It’s often used inside cable carriers in feeding lines for blast furnaces or in automated welding and cutting systems. This cable resists abrasion and won’t break down from exposure to chemicals and UV light. It meets IEC standards for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
For technical drawings and 3-D models, click on a part number.
Control Cable
- Use For:
Unshielded: Automation
Shielded: Automation; Interference Shielding - Flexible
- Temperature Range: 45° to 190° F
- Insulation: PVC Plastic
Send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. This cable is often used with conveyors, CNC machines, and to connect equipment to a control panel. The PVC insulation resists oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
No-Conduit-Required Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands periodic flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.36" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 00000 | 00000 | |
Double-Shielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.39" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 |
Thin-Insulation Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -40° to 220° F
- Insulation: Modified Polyphenylene Ether (mPPE) Plastic
Nearly two-thirds the diameter of standard control cable, this cable fits in tight spaces. The modified polyphenylene ether (mPPE) insulation is less than half the weight of the PVC insulation found on standard control cable, yet is more abrasion and cut resistant. Use it to send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. It’s often used with conveyors, CNC machines, and to connect equipment to a control panel. Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
14 | 3 | 14/3 | 24 A @ 86° F | 0.28" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | 000000 | |
Double-Shielded Stranded Wire | |||||||||||
600V AC | |||||||||||
14 | 3 | 14/3 | 24 A @ 86° F | 0.32" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Variable-Frequency Drive Motor Cable
This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power wires sends electricity to run a motor. Cable with three uninsulated ground wires pairs a ground wire with each power wire, so you can create multiple circuits from the same cable. These wires aren’t counted in the cable’s number of wires.
For technical drawings and 3-D models, click on a part number.
- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Inner Insulation: Polyethylene Plastic
Armored Building Cable
- Use For: Buildings
- Flexible
- Temperature Range:
MC, THHN: 15° to 190° F
MC, XHHW-2: -40° to 190° F - Outer Insulation:
MC, THHN: Aluminum Armor
MC, XHHW-2: Aluminum Armor, PVC Plastic - Inner Insulation:
MC, THHN: PVC Plastic
MC, XHHW-2: Cross-Linked Polyethylene (XLPE)
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Cable with THHN wire stands up to condensation and moisture in basements and other damp environments.
Cable with XHHW-2 wire has a PVC outer jacket over the aluminum armor. You can use it in wet environments where liquid might drip and splash on it. It can also be used for direct burial without a conduit.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
MC, THHN Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
MC, XHHW-2 Stranded Wire | ||||||||||||||
600V AC/600V DC | ||||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.64" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 |
Building Cable
- Use For:
NM-B, THHN: Buildings
UF-B, THHN: Buildings, Outdoors - Bend and Stay
- Temperature Range: 10° to 190° F
- Insulation: PVC Plastic
Rated for in-wall installation, this cable carries power to wall outlets. Also known as branch circuit wire, it can be used without conduit. It has solid THHN building wires, so the cable will stay in the shape you bend it. The uninsulated ground wire is not counted in the number of wires.
NM-B cable is for dry locations where moisture is not a concern, and often run through walls, ceilings, and concrete blocks.
UF-B cable is for wet locations where cable may be exposed to moisture or humidity. It's often used as underground feeder cable for pumps and lighting. The insulation resists moisture and UV light.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-249 | 250-Up | |
NM-B, THHN Solid Wire | |||||||||||||
600V AC | |||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | 0.18" | Blue | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 00000 | 00000 | |
UF-B, THHN Solid Wire | |||||||||||||
600V AC | |||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.58" | 0.17" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 000 |
Armored Building Cable with Fittings
- Use For: Buildings
- Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: Steel Armor
Inner: PVC Plastic
Also known as fixture whips, this cable has locknuts and fittings attached to the metal armor to secure to a knockout. The armor acts as conduit to protect the THHN building wires. It has 6" long wire leads for hardwiring to an existing electrical system, and is often used to connect light fixtures.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Includes | Industry Designation | Specifications Met | Lg., ft. | Each | |
Solid Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 000000 |
Armored Building Cable with Uninsulated Ground Wire
- Use For: Buildings
- Flexible
- Temperature Range: 15° to 190° F
- Insulation:
Outer: Aluminum Armor
Inner: PVC Plastic
Also known as AC cable, this cable has an uninsulated aluminum ground wire that's in constant contact with the aluminum armor, so it can be used for bonding and grounding. The uninsulated ground wire is not counted in the number of wires. The armor acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. All are flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Power Cords
Connect equipment and devices to a power supply.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
SJEOW cords have an oil- and water-resistant insulation. The insulation on STW and SJTW cords resists water. Use SJT cords in dry or damp locations.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
14 | 15 | 125V AC | 6 | 0.37" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
14 | 15 | 125V AC | 6 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000000 | 0000 |
14 | 15 | 125V AC | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.37" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
90° Elbow NEMA 5-15 Plug × Wire Leads | |||||||||||
14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
Light Duty Power Cords
Designed for indoor applications, these cords are often used to power appliances.
SPT cords have a flat cord shape so they fit in tight spaces. The numbers 1, 2, and 3 indicate the relative thickness of the insulation.
Use SJT cords in dry or damp locations.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Wd. | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
14 | 15 | 125V AC | 6 | __ | 0.52" | PVC Plastic | SPT-3 | -40° to 140° | UL Listed, C-UL Listed | Beige | 00000000 | 000000 |
14 | 15 | 125V AC | 9 1/2 | 0.38" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
Sure-Grip Power Cords
Also known as hospital-grade cords, these cords have an extra-tight connection to prevent them from detaching. The plug is marked with a green dot.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-20 Plug × Wire Leads | |||||||||||
14 | 20 | 125V AC | 10" | 0.37" | PVC Plastic | SJT | -20° to 220° | UL Listed, C-UL Listed | Gray | 00000000 | 00000 |
GFCI Power Cords
Stop electric shocks before they happen—these cords cut power to equipment when they detect an unsafe current. Once the surge has passed, an automatic reset resumes the flow of power. These SJTW cords have insulation that protects them from water, so they’re safe to use in outdoor charging stations and other wet areas. To help it fit behind machinery and in other tight spaces, the plug has a 90° elbow that sits flush against outlets. Hardwire the other end to your equipment or attach an electrical connector to make your own GFCI-protected extension cord.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | GFCI Location | Reset Type | Power-Indicating Light | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
90° Elbow NEMA 5-15 Plug × Wire Leads | ||||||||||||||
14 | 15 | 125V AC | 15 | 0.4" | PVC Plastic | Plug | Automatic | With Power-Indicating Light | SJTW | -30° to 150° | UL Listed, C-UL Listed | Black | 0000000 | 000000 |
Safety Start-Up Power Cords
After shutting off power to equipment during a power failure, these cords must be manually reset, preventing unexpected equipment start-up. Use them to replace three-wire power cords on equipment driven by small single-phase motors. The industry designation is SJTO, so the insulation resists oil.
Wire Gauge | Current, A | Voltage | Lg., ft. | Cord OD | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
Wire Leads × Wire Leads | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
14 | 15 | 250V AC | 8 × 1 1/2 | 0.38" | SJTO | 32° to 165° | UL Recognized Component, C-UL Recognized Component | Black | 0000000 | 0000000 |
14 | 18 | 125V AC | 8 × 1 1/2 | 0.38" | SJTO | 32° to 165° | UL Recognized Component, C-UL Recognized Component | Black | 0000000 | 000000 |
NEMA 5-15 Plug × Wire Leads | ||||||||||
14 | 15 | 125V AC | 8 × 1 1/2 | 0.38" | SJTO | 32° to 165° | UL Recognized Component, C-UL Recognized Component | Black | 0000000 | 000000 |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
14 | 15 | 125V AC | 1 × 1 | 0.38" | SJTO | 32° to 165° | UL Recognized Component, C-UL Recognized Component | Black | 0000000 | 000000 |
Turn-Lock Power Cords
The plug on these cords turns to lock in an outlet, so they remain securely attached in high-vibration applications.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA Plug × Wire Leads | ||||||||||||
L5-15 | 14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 000000 |
L6-15 | 14 | 15 | 250V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |