About Wire and Cable
More
About Industry Designation for Cable Insulation
More
About Extension Cords
More
Cable
Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Inner Insulation Color | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
8 | 3 | 8/3 | 40 A @ 86° F | -55° to 220° | 0.7" | Black, Green, White | Bare Copper | 0000000 | 00000 | 00000 | |
8 | 4 | 8/4 | 35 A @ 86° F | -55° to 220° | 0.78" | Black, Green, Red, White | Bare Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
8 | 3 | 8/3 | 40 A @ 86° F | 0.86" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 000000 | 00000 | |
8 | 4 | 8/4 | 35 A @ 86° F | 0.96" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
8 | 5 | 8/5 | 28 A @ 86° F | 0.84" | Black, Green, Orange, Red, White | __ | Bare Copper | 0000000 | 00000 | 0000 |
Corrosion-Resistant Cable
- Use For: Boats, Motors, Panel and Equipment (Hook-Up), Power Supply
- Flexible
- Temperature Range: -40° to 230° F
- Insulation:
Outer: Chlorinated Polyethylene Plastic
Inner: See table
The chlorinated polyethylene insulation resists corrosive chemicals and salt water, and the wires are tin plated for corrosion resistance. This cable also withstands oil and solvents. It’s rated UL 1309 for use as marine shipboard cable.
Cable with braided bronze armor has excellent protection against abrasion and other damage.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with Polyolefin Plastic Inner Insulation | |||||||||||
600V AC | |||||||||||
8 | 4 | 8/4 | 40 A @ 86° F | 0.7" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Polyolefin Plastic, Braided Bronze Armor Inner Insulation | |||||||||||
600V AC | |||||||||||
8 | 4 | 8/4 | 40 A @ 86° F | 0.92" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 |
Low-Voltage Cable
- Use For: Appliances, Vehicles
- Flexible
- Temperature Range: -40° to 175° F
- Insulation: PVC Plastic
Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
High-Voltage Cable
- Use For: Power Supply, Outdoors
- Flexible
- Temperature Range: -40° to 190° F
- Insulation: EPDM Rubber
Often used in mining equipment, submersible pumps, and drilling rigs, this cable withstands 2,000 volts AC/DC. The EPDM insulation resists abrasion, so it can be pulled over rough surfaces without damaging the wires inside.
Drop-Down Cable
Often used to wire pendant switches, this cable hangs from an overhead connection. It’s also known as bus drop cable.
The PVC insulation resists abrasion, chemicals, and oil.
Cable with three uninsulated ground wires can be used in wet environments. The ground wires are not counted in the number of wires.
- Use For: Drop-Down Power
- Flexible
- Temperature Range: -40° to 140° F
- Insulation: PVC Plastic
Oil-Resistant Continuous-Flex Cable
This cable has an insulation with excellent resistance to oil, so it can be used near motors and equipment that require oil lubrication. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Insulation:
300 and 1000V AC: TPE Rubber Inner Insulation
600V AC: PVC Plastic Inner Insulation
See Table for Outer Insulation - Environment:
300 and 1000V AC: Clean Room
600V AC: Not Rated - Specifications Met:
300 and 1000V AC: UL Recognized Component, C-UL Recognized Component, Flame Rated VW-1
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
1,000V AC | ||||||||||||||
8 | 4 | 8/4 | 69 A @ 86° F | 25° to 155° | 0.71" | 5.18" | PVC Plastic | Black | Black, Green/Yellow | ISO Class 2 | 0000000 | 000000 | 000000 | |
8 | 5 | 8/5 | 51 A @ 86° F | 25° to 155° | 0.79" | 5.93" | PVC Plastic | Black | Black, Green/Yellow | ISO Class 2 | 0000000 | 00000 | 00000 |
- Use For: Shielded: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Insulation:
600V AC: PVC Plastic Inner Insulation
1,000V AC: TPE Rubber Inner Insulation
See Table for Outer Insulaton - Environment:
600V AC: Not Rated
1,000V AC: Clean Room - Specifications Met:
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
1,000V AC: UL Recognized Component, C-UL Recognized Component, Flame-Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
1,000V AC | ||||||||||||||
8 | 4 | 8/4 | 69 A @ 86° F | 25° to 155° | 0.83" | 6.08" | PVC Plastic | Black | Black, Green/Yellow | ISO Class 2 | 0000000 | 000000 | 000000 | |
8 | 5 | 8/5 | 51 A @ 86° F | 25° to 155° | 0.91" | 6.68" | PVC Plastic | Black | Black, Green/Yellow | ISO Class 2 | 0000000 | 00000 | 00000 |
No-Conduit-Required Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands periodic flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
8 | 4 | 8/4 | 55 A @ 86° F | 0.7" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 00000 | 00000 | |
8 | 5 | 8/5 | 44 A @ 86° F | 0.77" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 00000 | 0000 | |
Double-Shielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
8 | 4 | 8/4 | 55 A @ 86° F | 0.74" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 00000 | 0000 |
Variable-Frequency Drive Motor Cable
This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power wires sends electricity to run a motor.
- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Inner Insulation: Nylon Plastic, PVC Plastic
Flat Control Cable
- Use For: Automation
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Also known as festoon cable, this flat cable fits in confined spaces and withstands period flexing and bending, such as in overhead cranes and hoists. Use it to operate, measure, or regulate automated equipment. The PVC insulation resists oil and UV light. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
For technical drawings and 3-D models, click on a part number.
Welding Cable
- Use For: Welding
- 600V AC: Bend and Stay
600V AC/DC: Flexible - Temperature Range: -55° to 220° F
- Insulation: EPDM Rubber
This cable withstands abrasion, oil, and the rough conditions found in welding applications. It’s flame rated VW-1 to meet requirements for vertical flame testing.
Class K cable is for general purpose welding applications. It bends and stays in the position that you bend it.
For technical drawings and 3-D models, click on a part number.
Machine Tool Wire
- Use for panel and equipment (hook-up)
- Flexibility: See table
- Temperature Range:
600V AC Stranded Wire: 0° to 190° F
600V AC/600V DC Stranded Wire: -40° to 190° F
600V AC/600V DC Metric Stranded Wire: -40° to 220° F - Insulation: PVC Plastic
More flexible than standard wire, this wire is often used for internal appliance wiring. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire. Also known as MTW wire, it’s rated UL 1063 for machine tool wiring.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Wire Ga. | Strand Count | Current | OD | Flexibility | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
Stranded Wire | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||
8 | 19/21 | 50 A @ 86° F | 0.21" | Flexible | MTW | UL Listed, C-UL Listed, UL 2556 VW-1, UL 1063 | Blue | 00000000 | 00000 | |
8 | 19/21 | 50 A @ 86° F | 0.24" | Flexible | MTW | UL Listed, CSA Certified, UL 2556 VW-1, UL 1063 | 0000000 | 0000 |
Wire Ga. | Strand Count | Current | OD | Flexibility | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Lg., ft. | Each | |
Stranded Wire | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||
8 | 19/21 | 50 A @ 86° F | 0.21" | Flexible | MTW | UL Listed, C-UL Listed, UL 2556 VW-1, UL 1063 | Blue | 500 | 00000000 | 0000000 |
8 | 19/21 | 50 A @ 86° F | 0.24" | Flexible | MTW | UL Listed, CSA Certified, UL 2556 VW-1, UL 1063 | 500 | 0000000 | 000000 |
Abrasion-Resistant Wire
Run power over rough surfaces—this wire has thick insulation that stands up to wear and tear. It’s flame rated, which means it meets requirements for preventing the spread of fire. Also known as hook-up wire.
Wire with FEP insulation won’t become brittle from chemicals, and it withstands extreme temperatures, from -90° to 390° F.
Wire with silicone rubber insulation is the most flexible wire we offer. It bends easily around tight turns without cracking.
For technical drawings and 3-D models, click on a part number.
- Use for panel and equipment (hook-up)
- Flexible
- Temperature Range: -90° to 390° F
- Use for panel and equipment (hook-up)
- Ultra Flexible
- Temperature Range: -40° to 300° F
High-Temperature Wire
- Use for ovens and furnaces
- Fiberglass Fabric Outer Insulation: Flexible
Ceramic Fabric Outer Insulation: Bend and Stay - Temperature Range: See table
Even at 480° F—hotter than some industrial ovens—this wire’s insulation won’t melt.
Wire with a fiberglass outer and mica inner insulation is the common choice for steel mills, iron mills, and glass manufacturing. You may know it as MG wire. Wire with a silicone-coated outer insulation shields your skin from fiberglass particles when handling the wire.
Wire with a fiberglass outer and PTFE inner insulation won’t corrode from moisture, so it’s often used in industrial drying equipment. It also won’t become brittle or crack from chemicals. This wire is commonly known as TGGT wire.
Wire with a ceramic fabric outer insulation withstands the hottest temperatures of our offering, so you can safely run it near open flames. It’s flame rated VW-1 to prevent the spread of fire. This wire won’t become brittle or crack from chemicals. Bend it and it stays in place.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | Min. Temp., °F | Max. Temp., °F | OD | Outer Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with Fiberglass Fabric Outer and Mica Inner Insulation | ||||||||||||
600V AC/600V DC | ||||||||||||
8 | 133/29 | 159 A @ 86° F 87 A @ 600° F | -40° | 840° | 0.27" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Silicone-Coated Fiberglass Fabric Outer and Mica Inner Insulation | ||||||||||||
600V AC/600V DC | ||||||||||||
8 | 133/29 | 130 A @ 86° F | Not Rated | 1020° | 0.27" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 0000 | |
Stranded Wire with Fiberglass Fabric Outer and PTFE Plastic Inner Insulation | ||||||||||||
600V AC | ||||||||||||
8 | 133/29 | 30 A @ 400° F 88 A @ 86° F | -65° | 480° | 0.23" | Beige | TGGT | UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Ceramic Fabric Outer and Mica Inner Insulation | ||||||||||||
300V AC | ||||||||||||
8 | 168/30 | 43 A @ 86° F | -40° | 1830° | 0.29" | Beige | __ | UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Battery Wire
Connect batteries in vehicles and generators.
Strand count is the number of strands followed by the size of the individual strand.
Wire with a PVC plastic insulation resists fuel and oil.
SAE wire meets standards for low-voltage wiring in vehicle electrical systems.
For technical drawings and 3-D models, click on a part number.
Vehicle Wire
Originally designed to meet the quality standards of the auto industry, this wire withstands high temperatures, flames, and abrasion. Unlike other low-voltage wires, this wire meets strict SAE performance requirements. You'll often hear it referred to as primary wire in trucks, trailers, forklifts, and other vehicles.
In protected environments, such as vehicle interiors, GPT wire is the best choice.
For technical drawings and 3-D models, click on a part number.
Corrosion-Resistant Battery Wire
- Use for boats, vehicles
- Flexible
- Temperature Range: 0° to 220° F
Connect batteries in generators, forklifts, and other vehicles in corrosive environments. Also known as marine wire, this copper wire is tin plated to resist corrosion from salt water, battery acid, and oil. Designed for boats, it's a good choice for use outdoors. The PVC insulation stands up to fuel and oil. Strand count is the number of strands followed by the size of the individual strand.
For technical drawings and 3-D models, click on a part number.
Building Wire
- Use for buildings
- Stranded Wire: Flexible
Solid Wire: Bend and Stay - Temperature Range:
Wire with Nylon Outer Insulation: -10° to 190° F
Wire with Polyethylene Outer Insulation: -40° to 190° F
Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Wire with a nylon outer insulation resists oil and water. Wire with a polyethylene outer insulation resists abrasion and chemicals. It’s more flexible than nylon insulated wire.
XHHW-2 wire is for dry and wet locations where wire may be exposed to dripping or splashing liquid. THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement. THWN and THWN-2 wire can be used in both wet and dry environments.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
8 | 19/21 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 |
Continuous-Flex Wire
- Use for automation, continuous motion
- Continuous Flex
- Temperature Range:
All but Wire with Inner Insulation: -40° to 175° F
Wire with Inner Insulation: 45° to 190° F
Often used in automated applications such as robotics, this wire withstands continuous motion without degrading data or signal transmission.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Wire is a UL recognized component.
For technical drawings and 3-D models, click on a part number.
Per Ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Specifications Met | Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with PVC Plastic Outer Insulation with Cloth Tape and PVC Plastic Inner Insulation | |||||||||
600V AC | |||||||||
8 | 320/32 | 80 A @ 86° F | 0.36" | CSA Certified, UL Recognized Component, UL 2556 VW-1 | Black | 000000 | 00000 | 00000 |
High-Voltage Continuous-Flex Wire
- Use for solar equipment, automation, continuous motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick insulation protects this wire from high voltages while maintaining flexibility. The insulation also resists moisture. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It meets UL 94 V-0 for flame retardance. If this wire is exposed to flames, it minimizes how much smoke and halogen it releases.
For technical drawings and 3-D models, click on a part number.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||
42,000V DC/59,000V AC | ||||||||||||
8 | 1,666/40 | 65 A @ 86° F | 0.39" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 000000 | 000000 |
Chemical-Resistant Continuous-Flex Wire
- Use for automation, continuous motion
- Continuous Flex
- Temperature Range: -30° to 190° F
- Insulation: TPE Rubber
Insulated with TPE, this wire won’t break down from oil, coolant, or chemicals, and it carries a strong signal even when repeatedly bent. This makes it great for greasy equipment on automated lines, such as lubricated cable carriers. Its insulation also stands up to moisture and sunlight, so you can use this wire outdoors. This wire is flame rated FT1, which means it meets requirements for preventing the spread of fire.
Unshielded wire works in most applications. You can twist it 90° while pulling and bending it at the same time.
Choose shielded wire if you need protection against signal interference from nearby equipment, such as variable frequency drives or small motors. Braid-shielded wire blocks signal interference better than spiral-shielded wire. While it can bend and flex continuously, the shielding may tear if repeatedly twisted. Spiral-shielded wire balances good signal interference and flexibility. It's the most flexible wire we offer, so it will bend, flex, and twist 180° without stretching or snapping.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Current | OD | Torsion Angle | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
1,000V AC | |||||||||||
8 | 74 A @ 86° F | 0.31" | 90° | Black | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, UL 2556 FT1 | 0000000 | 00000 | 00000 | |
Stranded Wire with Braid Shield | |||||||||||
1,000V AC | |||||||||||
8 | 74 A @ 86° F | 0.33" | __ | Black | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, UL 2556 FT1 | 0000000 | 0000 | 0000 | |
Stranded Wire with Spiral Shield | |||||||||||
1,000V AC | |||||||||||
8 | 72 A @ 86° F | 0.41" | 180° | Black | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, UL 2556 FT1 | 0000000 | 00000 | 00000 |
Outdoor Wire
The EPDM insulation on this wire won’t become brittle or crack from sunlight, humidity, rain, temperature changes, abrasion from dirt and debris, and other rough outdoor conditions. It meets Mine Safety and Health Administration (MSHA) standards for material quality.
DLO wire carries higher voltages than SC wire, making it the better choice for heavy duty applications. Use it to run power to motors, cranes, and other equipment in shipyards, mines, and oil- and gas-drilling rigs. Also known as diesel locomotive cable, this wire was originally designed to wire trains. An inner layer of chlorinated polyethylene plastic (CPE) gives it increased resistance to chemicals, heat, and flames. It’s also rated RHW-2, so it can be used underground and in wet locations.
All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT4 wire is mounted to a vertical tray during testing.
For technical drawings and 3-D models, click on a part number.
- Use for outdoors, buildings, power supply
- Flexible
- Maximum Temperature: 190° F
- Insulation:
Outer: EPDM Rubber
Inner: Chlorinated Polyethylene Plastic, Polyethylene Plastic
UV-Resistant Wire
- Use for outdoors, buildings, solar equipment, power supply
- Flexible
- Temperature Range: -40° to 190° F
- Insulation: Cross-Linked Polyethylene (XLPE)
Also known as photovoltaic (PV) wire, this wire won’t deteriorate from UV light when used outdoors. Often used in solar panels, the cross-linked polyethylene (XPLE) insulation won’t break down from prolonged exposure to high temperatures. The insulation also resists chemicals. An RHW-2 industry designation means this wire withstands underground and wet locations.
For technical drawings and 3-D models, click on a part number.
Per Ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Outer Insulation Color | 1-99 | 100-Up | |
Stranded Wire | |||||||||
8 | 157/29 | 98 A @ 86° F | 0.28" | PV, RHW-2 | UL Listed, UL 2556 VW-1 | Black | 0000000 | 00000 | 00000 |
Power Cords
Connect equipment and devices to a power supply.
Cords with a NEMA 14-30 or 14-50 plug are often used to power electric vehicles. They have a high current rating.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
The insulation on STW and SJTW cords resists water. SRDT cords are for use with high-current equipment, such as ranges and dryers.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Wd. | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
90° Elbow NEMA 10-50 Plug × Spade Terminals | ||||||||||||
8, 6 | 50 | 125V AC/250V AC | 4 | __ | 1.03" | PVC Plastic | SRDT | 0° to 140° | UL Listed | Gray | 000000000 | 000000 |
8, 6 | 50 | 125V AC/250V AC | 6 | __ | 1.03" | PVC Plastic | SRDT | 0° to 140° | UL Listed | Gray | 00000000 | 00000 |
90° Elbow NEMA 14-50 Plug × Wire Leads | ||||||||||||
8, 6 | 50 | 125V AC/250V AC | 4 | 1.08" | __ | PVC Plastic | STW | 0° to 140° | UL Listed | Black | 000000000 | 00000 |
8, 6 | 50 | 125V AC/250V AC | 30 | 1.08" | __ | PVC Plastic | STW | 0° to 140° | UL Listed | Black | 000000000 | 000000 |
8, 6 | 50 | 125V AC/250V AC | 36 | 1.08" | __ | PVC Plastic | STW | 0° to 140° | UL Listed | Black | 000000000 | 000000 |
90° Elbow NEMA 14-50 Plug × Spade Terminals | ||||||||||||
8, 6 | 50 | 125V AC/250V AC | 4 | 0.8" | __ | PVC Plastic | SRDT | 0° to 140° | UL Listed | Black | 000000000 | 00000 |
8, 6 | 50 | 125V AC/250V AC | 6 | 0.8" | __ | PVC Plastic | SRDT | 0° to 140° | UL Listed | Black | 00000000 | 00000 |
Extension Cords for Welding
Run power to welders in machine shops, garages, and other areas where these cords will be exposed to harsh conditions. These cords have either EPDM or PVC insulation that protects the cord's wires from weld slag and being dragged, kicked, and stepped on. Their insulation also won't crack or become brittle when exposed to oil, water, and weather. They also stay flexible across a wide range of temperatures. A power-indicating light on the socket illuminates when the cord has power.
NEMA 6-50 cords can be used with higher voltage equipment than NEMA 5-15 cords. Use them with portable MIG welders rated up to 400 amps as well as TIG welders, stick welders, and plasma cutters rated up to 250V AC. They have a light that illuminates when they’re grounded safely. A handle makes them easy to plug in and unplug.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Features | Color | Each | |
NEMA 6-50 Plug × NEMA 6-50 Socket | |||||||||||
25 ft. | |||||||||||
8 | 50 | 250V AC | With Power-Indicating Light | 0.85" | PVC Plastic | STW | ETL Listed, C-ETL Listed | Ground-Indicating Light, Handle | Black | 0000000 | 0000000 |
50 ft. | |||||||||||
8 | 50 | 250V AC | With Power-Indicating Light | 0.85" | PVC Plastic | STW | ETL Listed, C-ETL Listed | Ground-Indicating Light, Handle | Black | 0000000 | 000000 |
Abrasion-Resistant Extension Cords
Thick insulation protects the internal wires of these cords, so they can be used in high-traffic areas and over rough surfaces. The industry designation is STW, so the insulation resists water.
Cords with a NEMA 14-50 plug and socket have a high current rating and are often used to power electric vehicles. The light on their socket illuminates when the cord has power. Their plug and socket have handles, making them easy to grip when plugging or unplugging them.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Current, A | Voltage | Power-Indicating Light | Features | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
90° Elbow NEMA 14-50 Plug × NEMA 14-50 Socket | |||||||||||
15 ft. | |||||||||||
8, 6 | 50 | 125V AC/250V AC | With Power-Indicating Light | Handle | 1.08" | PVC Plastic | STW | UL Listed, C-UL Listed | Black | 00000000 | 0000000 |
30 ft. | |||||||||||
8, 6 | 50 | 125V AC/250V AC | With Power-Indicating Light | Handle | 1.08" | PVC Plastic | STW | UL Listed, C-UL Listed | Black | 00000000 | 000000 |
50 ft. | |||||||||||
8, 6 | 50 | 125V AC/250V AC | With Power-Indicating Light | Handle | 1.08" | PVC Plastic | STW | UL Listed, C-UL Listed | Black | 00000000 | 000000 |
Grounding Wire
Ground your electrical system.