Blade-Style Circuit Breakers
Protect against overload and short circuits in low-voltage automotive and other electronic applications. These circuit breakers can replace type ATC, AF, ATO, and 257 blade-style fuses. They are thermal, so they trip when heat is generated by overload current.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
Automatic reset breakers don’t require you to manually reset them after they trip, so they’re good for areas where the breaker isn’t easily accessed. These breakers reset once they cool. However, they will trip repeatedly if the overcurrent condition continues.
Manual reset breakers require you to push a button after they trip.
Place UL1077 rated breakers downstream from a branch circuit breaker to protect a single piece of equipment from overloads and short circuits. They are also known as supplemental protectors.
Current, A | Breakthrough Current | Mounting Location | Ht. | Wd. | Blade Ht. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
12V DC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
6 | 2,000 A @ 12 V DC | Fuse Block | 0.95" | 0.79" | 0.25" | -40° to 185° | IP54 | SAE J553 | 0000000 | 00000 |
8 | 2,000 A @ 12 V DC | Fuse Block | 0.95" | 0.79" | 0.25" | -40° to 185° | IP54 | SAE J553 | 0000000 | 0000 |
10 | 2,000 A @ 12 V DC | Fuse Block | 0.95" | 0.79" | 0.25" | -40° to 185° | IP54 | SAE J553 | 0000000 | 0000 |
15 | 2,000 A @ 12 V DC | Fuse Block | 0.95" | 0.79" | 0.25" | -40° to 185° | IP54 | SAE J553 | 0000000 | 0000 |
20 | 2,000 A @ 12 V DC | Fuse Block | 0.95" | 0.79" | 0.25" | -40° to 185° | IP54 | SAE J553 | 0000000 | 0000 |
25 | 2,000 A @ 12 V DC | Fuse Block | 0.95" | 0.79" | 0.25" | -40° to 185° | IP54 | SAE J553 | 0000000 | 0000 |
Current, A | Breakthrough Current | Mounting Location | Ht. | Wd. | Blade Ht. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
24V DC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
6 | 2,000 A @ 24 V DC | Fuse Block | 1.16" | 0.79" | 0.25" | -40° to 185° | IP30 | __ | 0000000 | 000000 |
8 | 2,000 A @ 24 V DC | Fuse Block | 1.16" | 0.79" | 0.25" | -40° to 185° | IP30 | __ | 0000000 | 00000 |
10 | 2,000 A @ 24 V DC | Fuse Block | 1.16" | 0.79" | 0.25" | -40° to 185° | IP30 | __ | 0000000 | 00000 |
15 | 2,000 A @ 24 V DC | Fuse Block | 1.16" | 0.79" | 0.25" | -40° to 185° | IP30 | __ | 0000000 | 00000 |
20 | 2,000 A @ 24 V DC | Fuse Block | 1.16" | 0.79" | 0.25" | -40° to 185° | IP30 | __ | 0000000 | 00000 |
25 | 2,000 A @ 24 V DC | Fuse Block | 1.16" | 0.79" | 0.25" | -40° to 185° | IP30 | __ | 0000000 | 00000 |
30 | 2,000 A @ 24 V DC | Fuse Block | 1.16" | 0.79" | 0.25" | -40° to 185° | IP30 | __ | 0000000 | 00000 |
48V DC | ||||||||||
3 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
4 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
5 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
6 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
7 1/2 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
8 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
10 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
15 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
20 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
25 | 2,000 A @ 48 V DC | Fuse Block | 1 1/2" | 0.87" | 0.25" | -40° to 185° | IP40 | SAE J553 | 0000000 | 00000 |
250V AC/72V DC | ||||||||||
1/4 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
1/2 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
1 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
1 1/2 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
2 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
2 1/2 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
3 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
4 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
5 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
6 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
8 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
10 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | __ | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 00000 |
For DIN Rail Size, mm | Wire Connection Type | Each | |
35 | Screw-Clamp Terminals | 000000 | 000000 |