Square D Secondary Circuit Breaker Boxes
Connect these boxes to a main box—they do not have a main circuit breaker switch. They are single-phase, 3-wire, and can be mounted for top or bottom feed conduit connections. Also known as load centers.
NEMA 1 rated boxes are for indoor use.
NEMA 3R rated boxes are for outdoor use.
Circuit breakers meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits. Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6mA. This minimizes the risk of electric shock to workers and equipment.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
Cover | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Spaces | Current, A | Voltage | Frequency, Hz | Breakthrough Current | Mounting Style | Bus Bar Material | Attachment Style | Closure Method | Ht. | Wd. | Dp. | Specifications Met | Each | |
NEMA 1 Rated | ||||||||||||||
12 | 125 | 120V AC/240V AC | 50/60 | 65,000 A @ 120 V AC 65,000 A @ 240 V AC | Surface | Tin-Plated Copper | Lift Off | Screws | 17 7/8" | 14 1/4" | 3 3/4" | UL Listed | 0000000 | 0000000 |
NEMA 3R Rated | ||||||||||||||
12 | 125 | 120V AC/240V AC | 50/60 | 65,000 A @ 120 V AC 65,000 A @ 240 V AC | Surface | Tin-Plated Copper | Hinged | Latch | 18 7/8" | 14 3/4" | 4 1/2" | UL Listed | 0000000 | 000000 |
24 | 125 | 120V AC/240V AC | 50/60 | 65,000 A @ 120 V AC 65,000 A @ 240 V AC | Surface | Tin-Plated Copper | Hinged | Latch | 22" | 14 3/4" | 4 1/2" | UL Listed | 0000000 | 000000 |
Current, A | Voltage | Frequency, Hz | Breakthrough Current | Mounting Location | Wire Connection Type | Wd. | Specifications Met | Each | |
QO Series | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 000000 |
20 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 0000000 | 00000 |
40 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 00000 |
2 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
20 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
60 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
70 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 0000000 | 000000 |
3 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
15, 20, 30, 40 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 000000 | 000000 |
20 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
30 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
40 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
QO Series with 6mA Ground Fault Sensitivity | |||||||||
1 Pole—Toggle Style | |||||||||
20 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 000000 |
20, 30 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 0000000 | 000000 |
30 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 000000 |
2 Pole—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 000000 |
20, 30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 0000000 | 000000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 000000 |
Square D Homeline Secondary Circuit Breaker Boxes
Connect these boxes to a main box—they do not have a main circuit breaker switch. They are single-phase, 3-wire, and can be mounted for top or bottom feed conduit connections. Boxes are rated NEMA 1 for indoor use. Also known as load centers.
Circuit breakers meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits. Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6mA. This minimizes the risk of electric shock to workers and equipment.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Cover | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Spaces | Current, A | Voltage | Frequency, Hz | Breakthrough Current | Mounting Style | Bus Bar Material | Attachment Style | Closure Method | Ht. | Wd. | Dp. | Specifications Met | Each | |
NEMA 1 Rated | ||||||||||||||
12 | 125 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Recessed, Surface | Tin-Plated Aluminum | Lift Off | Screws | 17 7/8" | 14 1/4" | 3 3/4" | UL Listed | 0000000 | 000000 |
20 | 125 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Recessed, Surface | Tin-Plated Aluminum | Lift Off | Screws | 26" | 14 1/4" | 3 3/4" | UL Listed | 0000000 | 00000 |
Series, 1
Tandem Pole
Current, A | Voltage | Frequency, Hz | Breakthrough Current | Mounting Location | Wire Connection Type | Wd. | Specifications Met | Each | |
Homeline Series | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 000000 |
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 000000000 | 00000 |
1 Pole with Tandem Circuit—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
2 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 00000 |
60 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 00000 |
Homeline Series with 6mA Ground Fault Sensitivity | |||||||||
1 Pole—Toggle Style | |||||||||
20 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 000000 |
2 Pole—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 000000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 000000 |
Square D Homeline Main Circuit Breaker Boxes
With a main breaker installed and main service knockouts, these boxes are the entry point for electricity into your facility and the first step in protecting your electrical systems. They are single-phase, 3-wire, and can be mounted for top or bottom feed conduit connections. These boxes are rated NEMA 1 for indoor use. Also known as load centers.
Circuit breakers meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits. Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6mA. This minimizes the risk of electric shock to workers and equipment.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Cover | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Spaces | Current, A | Voltage | Frequency, Hz | Breakthrough Current | Mounting Style | Bus Bar Material | Attachment Style | Closure Method | Ht. | Wd. | Dp. | Specifications Met | Each | |
NEMA 1 Rated | ||||||||||||||
24 | 125 | 120V AC/240V AC | 50/60 | 22,000 A @ 120 V AC 22,000 A @ 240 V AC | Recessed, Surface | Tin-Plated Aluminum | Lift Off | Screws | 26" | 14 1/4" | 3 3/4" | UL Listed | 0000000 | 0000000 |
Series, 1
Tandem Pole
Current, A | Voltage | Frequency, Hz | Breakthrough Current | Mounting Location | Wire Connection Type | Wd. | Specifications Met | Each | |
Homeline Series | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 000000 |
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 000000000 | 00000 |
1 Pole with Tandem Circuit—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
2 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 00000 |
60 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 00000 |
Homeline Series with 6mA Ground Fault Sensitivity | |||||||||
1 Pole—Toggle Style | |||||||||
20 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 000000 |
2 Pole—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 000000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 000000 |
High-Power Circuit Breakers
Protect an area of a facility that has high-powered equipment. These circuit breakers are also known as molded case circuit breakers. They meet UL 489 requirements for branch circuit protection. Because these breakers are thermal-magnetic, they trip two ways. They either trip when heat is generated slowly by consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit. A switch lets you adjust when these breakers magnetically trip, so you don't need to replace them as your application changes. These breakers have internal accessory slots to fit shunt trips, auxiliary contacts, and undervoltage trips, saving space in your setup.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
Shunt trips receive a signal from equipment to trip your circuit breaker in situations other than overload or short circuit conditions. For example, use them with a smoke detector to shut off power to a system in the event of a fire. 30A to 250A breakers can only have one shunt trip or undervoltage trip installed. 400A to 600A breakers can accommodate one shunt trip and one undervoltage trip at the same time.
Auxiliary contacts send a signal to other equipment when the circuit trips. They can activate a warning light, initiate a shutdown, or start a backup power source. Multiple auxiliary contacts can be used within one circuit breaker and can be placed in any of the accessory slots.
Undervoltage trips protect equipment from operating with less than their intended voltage by tripping a circuit breaker when the supply voltage drops below a set level. 30A to 250A breakers can only have one shunt trip or undervoltage trip installed. 400A to 600A breakers can accommodate one shunt trip and one undervoltage trip at the same time.
Install handles on the front cover of an electrical cabinet to turn these breakers on, off, or reset them without having to open the cabinet. Yet, these handles won’t prevent you from opening the electrical cabinet normally. You can also lock the handles in the on or off position with a padlock (not included) to prevent unauthorized changes to the circuit breaker.
For technical drawings and 3-D models, click on a part number.
Current, A | Voltage | Frequency, Hz | Breakthrough Current | Inrush Current Setting, A | Mounting Location | For DIN Rail Size, mm | Mount Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
3 Pole—Toggle Style | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
125 | 480V AC/600YV AC/600V DC | 50/60 | 65,000 A @ 240 V AC 25,000 A @ 480 V AC 14,000 A @ 600 V AC 14,000 A @ 125 V DC 50,000 A @ 250 V DC 50,000 A @ 500 V DC 50,000 A @ 600 V DC | 625, 750, 875, 1,000, 1,125, 1,250 | DIN Rail | 35 | Screw On | 5.5" | 3" | 3" | -10° to 155° | UL 489, UL Listed, CE Marked, IEC 60947-2, IEC 81346-2 | 0000000 | 000000000 |
Voltage | Current | Frequency, Hz | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
110-127V AC | 7.4 A @ 110 V AC | 50/60 | Screw-Clamp Terminals | 2.56" | 0.85" | 1.23" | -10° to 155° | UL 489, UL Listed, IEC 60947-2 | 0000000 | 0000000 |
Voltage | Current, A | Frequency, Hz | Industry Designation | No. of Circuits Controlled | Switch Starting Position | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
24-300V AC/24-250V DC | 6 | 50/60 | DPST | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Screw-Clamp Terminals | 2.57" | 0.28" | 1.36" | -10° to 155° | UL 489, UL Listed, IEC 60947-2 | 0000000 | 0000000 |
Voltage | Current | Frequency, Hz | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
120-127V AC | 0.01 A @ 120 V AC | 50/60 | Screw-Clamp Terminals | 2.56" | 1.01" | 1.13" | -10° to 155° | UL 489, UL Listed, IEC 60947-2 | 0000000 | 0000000 |
For Circuit Breaker Current, A | Ht. | Wd. | Projection | Mounting Fasteners Included | For Max. Padlock Shackle Dia. | Padlock Included | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
30, 60, 100, 125 | 2.95" | 2.95" | 2.16" | Yes | 3/8" | No | -10° to 155° | IP65, NEMA 4X, NEMA 12 | IEC 60947-2 | 0000000 | 0000000 |