DIN-Rail Mount Branch Circuit Breakers
Mount these circuit breakers directly to DIN rail to protect equipment and wiring in an area of your facility from overloads and short circuits. They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit. Because they are thermal-magnetic, these breakers trip two ways. They either trip when heat is generated slowly by consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
C-trip circuit breakers are the most common. They’re best for applications such as lighting and control panels, where equipment startup causes a moderate spike in current. They won’t trip until a rush of current reaches 5 to 10 times their rated current.
Shunt trips receive a signal from equipment to trip your circuit breaker in situations other than overload or short circuit conditions. For example, use them with a smoke detector to shut off power to a system in the event of a fire.
Auxiliary contacts send a signal to other equipment when the circuit trips. They can activate a warning light, initiate a shutdown, or start a backup power source.
Distribution bars simplify wiring by powering multiple adjacent circuit breakers without needing separate wires for each one. This cuts down on assembly time and space.
Extension terminals raise the wire connection point above distribution bars for easy access to connect power to a set of circuit breakers.
Distribution bar terminal covers shield unused, live terminals on distribution bars to prevent injury and damage.
For technical drawings and 3-D models, click on a part number.
Current, A | Voltage | Frequency, Hz | Breakthrough Current | For DIN Rail Size, mm | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
C Trip Type | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 Pole—Toggle Style | ||||||||||||
1 1/2 | 277V AC/48V DC | 50/60 | 10,000 A @ 277 V AC 10,000 A @ 48 V DC | 35 | Screw-Clamp Terminals | 4.13" | 0.7" | 2.36" | -10° to 165° | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 00000000 | 000000 |
2 Pole—Toggle Style | ||||||||||||
1 1/2 | 277V AC/480YV AC/96V DC | 50/60 | 10,000 A @ 277 V AC 10,000 A @ 480 V AC 10,000 A @ 96 V DC | 35 | Screw-Clamp Terminals | 4.13" | 1.4" | 2.36" | -10° to 165° | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 00000000 | 000000 |
3 Pole—Toggle Style | ||||||||||||
1 1/2 | 277V AC/480YV AC | 50/60 | 10,000 A @ 277 V AC 10,000 A @ 480 V AC | 35 | Screw-Clamp Terminals | 4.13" | 2.09" | 2.36" | -10° to 165° | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 00000000 | 000000 |
Voltage | Current, A | Frequency, Hz | For DIN Rail Size, mm | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
12-110V AC/12-60V DC | 63 | 50/60 | 35 | Screw-Clamp Terminals | 4.13" | 0.7" | 2.36" | 25° to 100° | UL 489, UL Listed, CSA Certified, CE Marked, IEC 60898 | 00000000 | 000000 |
110-415V AC/110-230V DC | 40 | 50/60 | 35 | Screw-Clamp Terminals | 4.13" | 0.7" | 2.36" | 25° to 100° | UL 489, UL Listed, CSA Certified, CE Marked, IEC 60898 | 00000000 | 00000 |
Voltage | Current, A | Frequency, Hz | Industry Designation | No. of Circuits Controlled | Switch Starting Position | For DIN Rail Size, mm | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
250V AC | 6 | 50/60 | DPST | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 35 | Screw-Clamp Terminals | 3.78" | 0.35" | 2.36" | -10° to 165° F | UL 489, UL Listed, CSA Certified, CE Marked, IEC 60898 | 00000000 | 000000 |
Terminal | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For No. of Poles | No. of Terminals | Voltage | Current, A | Frequency, Hz | Ctr.-to-Ctr. | Wd. | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
1 | 12 | 277V AC/480YV AC/96V DC | 80 | 50/60 | 0.7" | 0.2" | 1.28" | 8.06" | 0.61" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 000000 |
2 | 12 | 277V AC/480YV AC/96V DC | 80 | 50/60 | 0.7" | 0.2" | 1.28" | 8.06" | 0.61" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 00000 |
3 | 12 | 277V AC/480YV AC/96V DC | 80 | 50/60 | 0.7" | 0.2" | 1.28" | 8.06" | 0.61" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 00000 |
For No. of Poles | Voltage | Current, A | Frequency, Hz | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
1, 2, 3 | 480V AC/96V DC | 80 | 50/60 | Screw-Clamp Terminals | 2.82" | 0.64" | 1.23" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 0000000 | 000000 |
For No. of Terminals | Ht. | Wd. | Dp. | Material | Temp. Range, °F | Specifications Met | Each | |
3 | 0.94" | 1.9" | 0.63" | Plastic | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 00000 |
Panel-Mount Equipment Circuit Breakers
Mount these breakers, also known as supplemental protectors, through panels downstream from a branch circuit breaker to protect a single piece of equipment. They are rated UL1077 for protection against overloads and short circuits. These breakers can also be used as on/off switches. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Current, A | Voltage | Frequency, Hz | Breakthrough Current | For Panel Cutout Dia. | Dp. Behind Panel | Mounting Fasteners Included | Quick-Disconnect Tab Wd. | Temp. Range, °F | Specifications Met | Each | |
1 Pole | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 1/2 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 000000 |
Blade-Style Circuit Breakers
Protect against overload and short circuits in low-voltage automotive and other electronic applications. These circuit breakers can replace type ATC, AF, ATO, and 257 blade-style fuses. They are thermal, so they trip when heat is generated by overload current.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
Manual reset breakers require you to push a button after they trip.
Place UL1077 rated breakers downstream from a branch circuit breaker to protect a single piece of equipment from overloads and short circuits. They are also known as supplemental protectors.
Current, A | Breakthrough Current | Mounting Location | Ht. | Wd. | Blade Ht. | Temp. Range, °F | Specifications Met | Each | |
250V AC/72V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 1/2 | 2,000 A @ 250 V AC 2,000 A @ 72 V DC | Fuse Block | 2.06" | 0.96" | 0.25" | 0° to 140° | UL 1077, UL Recognized Component, CSA Certified | 0000000 | 000000 |
For DIN Rail Size, mm | Wire Connection Type | Each | |
35 | Screw-Clamp Terminals | 000000 | 000000 |