About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
High-Output Blowers
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard blowers can handle. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, drying, ventilating, and exhausting. Blowers that weigh 280 lbs. or less can also be used for material conveying. Blowers with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
High-Output Blowers | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Wheels | ||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Each | Each | ||
Totally Enclosed Motor Enclosure | |||||||||||||||
230V AC, Single Phase—Hardwire | |||||||||||||||
1,080 cfm @ 5 in. of H₂O 1,230 cfm @ 3 in. of H₂O | 70 dBA @ 15 ft. | 3,450 | 3 | 5 15/16" | 7" | 13" | 21 1/8" | 19 1/8" | 18 1/16" | 100 | -10° to 150° | 0000000 | 000000000 | 00000000 | 0000000 |
120/230V AC, Single Phase—Hardwire | |||||||||||||||
615 cfm @ 5 in. of H₂O 845 cfm @ 3 in. of H₂O | 65 dBA @ 15 ft. | 3,450 | 2 | 5 15/16" | 7" | 10 5/8" | 21 1/8" | 19 1/8" | 18 5/16" | 95 | -10° to 150° | 0000000 | 00000000 | 00000000 | 000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||
615 cfm @ 5 in. of H₂O 845 cfm @ 3 in. of H₂O | 65 dBA @ 15 ft. | 3,450 | 2 | 5 15/16" | 7" | 10 5/8" | 21 1/8" | 19 1/8" | 17 7/8" | 87 | -10° to 150° | 0000000 | 00000000 | 00000000 | 000000 |
1,000 cfm @ 5 in. of H₂O 1,200 cfm @ 3 in. of H₂O | 70 dBA @ 15 ft. | 3,450 | 3 | 6" | 7" | 13" | 21 1/8" | 19 1/8" | 18 7/8" | 95 | -10° to 150° | 0000000 | 00000000 | 0000000 | 000000 |
High-Output Spark-Resistant Blowers
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
With Round Outlet and Inlet—Totally Enclosed Motor Enclosure | |||||||||||||||
120/230V AC, Single Phase—Hardwire | |||||||||||||||
900 cfm @ 5 in. of H₂O 1,090 cfm @ 3 in. of H₂O | 71 dBA @ 15 ft. | 3,450 | 3 | 6" | 7" | 11 1/2" | 21 5/16" | 18 1/2" | 18 1/2" | 142 | -10° to 150° | No | 7/16" | 0000000 | 000000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||
900 cfm @ 5 in. of H₂O 1,090 cfm @ 3 in. of H₂O | 71 dBA @ 15 ft. | 3,450 | 3 | 6" | 7" | 11 1/2" | 21 5/16" | 18 1/2" | 18 1/2" | 135 | -10° to 150° | No | 7/16" | 0000000 | 00000000 |
1,240 cfm @ 5 in. of H₂O 1,400 cfm @ 3 in. of H₂O | 74 dBA @ 15 ft. | 3,450 | 5 | 6" | 7" | 13" | 21 5/16" | 18 1/2" | 18 1/2" | 162 | -10° to 150° | No | 7/16" | 0000000 | 00000000 |
High-Output Hazardous Location Spark-Resistant Blowers
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard hazardous location spark-resistant blowers can handle. They have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
With Round Outlet and Inlet | |||||||||||||||
230/460V AC, Three Phase—Hardwire | |||||||||||||||
1,090 cfm @ 3 in. of H₂O | 71 dBA @ 15 ft. | 3,450 | 3 | 6" | 7" | 11 1/2" | 21 5/16" | 18 1/2" | 21 3/4" | 167 | -10° to 150° | No | 7/16" | 00000000 | 000000000 |
1,400 cfm @ 3 in. of H₂O | 74 dBA @ 15 ft. | 3,450 | 5 | 6" | 7" | 13" | 21 5/16" | 18 1/2" | 21 3/4" | 183 | -10° to 150° | No | 7/16" | 00000000 | 00000000 |