About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Blowers
These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Blowers | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet | Overall | Replacement Wheels | ||||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | Each | ||
With Rectangular Outlet and Round Inlet—Open Dripproof Motor Enclosure | ||||||||||||||||||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||||
1,500 cfm @ 3/4 in. of H₂O 1,800 cfm @ 1/4 in. of H₂O | 55 dBA @ 15 ft. | 1,150 | 3/4 | 11 3/4" | 8" | 10" | 10 5/8" | 22 1/2" | 18 7/8" | 17 1/4" | 84 | -15° to 180° | No | 3/8" | 0000000 | 000000000 | 0000000 | 0000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
1,500 cfm @ 3/4 in. of H₂O 1,800 cfm @ 1/4 in. of H₂O | 55 dBA @ 15 ft. | 1,150 | 3/4 | 11 3/4" | 8" | 10" | 10 5/8" | 22 1/2" | 18 7/8" | 17 1/4" | 67 | -15° to 180° | No | 3/8" | 0000000 | 00000000 | 0000000 | 000000 |
Chemical-Resistant Blowers
For resistance to chemicals as well as corrosion, these blowers have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
PVC plastic housing offers greater chemical resistance than the fiberglass housing. It resists strong oxidizing acids such as sulfuric acid but will not withstand contact with perchloric acid.
For technical drawings and 3-D models, click on a part number.
Blowers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet | Overall | Mounting | Replacement Wheels | ||||||||||||||
Airflow @ Static Pressure | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Housing Material | Fasteners Included | Hole Dia. | Each | Each | ||
208-230/460V AC, Three Phase—Hardwire | |||||||||||||||||
2,300 cfm @ 1/2 in. of H₂O 2,300 cfm @ 1 in. of H₂O | 1,725 | 1 1/2 | 9 3/8" | 6 11/16" | 10" | 12" | 24 1/4" | 23" | 24 1/4" | 124 | PVC Plastic | No | 3/8" | 0000000 | 000000000 | 0000000 | 000000000 |
Hazardous Location Chemical-Resistant Blowers
These blowers have an explosion-proof motor that is UL listed and CSA certified for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G hazardous locations. For resistance to chemicals as well as corrosion, they have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
PVC plastic housing offers greater chemical resistance than the fiberglass housing. It resists strong oxidizing acids such as sulfuric acid but will not withstand contact with perchloric acid.
For technical drawings and 3-D models, click on a part number.
Blowers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet | Overall | Mounting | Replacement Wheels | |||||||||||||
Airflow @ Static Pressure | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Housing Material | Fasteners Included | Hole Dia. | Each | Each | ||
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
2,300 cfm @ 1/2 in. of H₂O 2,300 cfm @ 1 in. of H₂O | 1,725 | 1 1/2 | 9 3/8" | 6 11/16" | 10" | 12" | 24 1/4" | 23" | 24 1/4" | PVC Plastic | No | 3/8" | 0000000 | 000000000 | 0000000 | 000000000 |