About Sound Levels
To choose an alarm or speaker that’s loud enough, first determine the decibel (dB) rating of background noise.
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Hazardous Location Equipment-Cooling Fans


Safely cool electronics and equipment where explosive gases could be present due to equipment failure. ATEX certified, these fans meet European standards for hazardous locations. They’re also IP rated, so they seal out dust and are protected from water if briefly submersed. All have ball bearings that decrease noise for quiet operation. Their bearings reduce heat as they run as well, extending their life.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Depth | Airflow, cfm | Temp. Range, °F | Volume, dBA | Current, A | Frame Material | Blade Material | Mounting Fasteners Included | Mounting Hole Diameter | Environmental Rating | Specifications Met | Each | |
Square | ||||||||||||||
100-240V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminals | ||||||||||||||
4.72" (120 mm) | 4.72" (120 mm) | 1.5" (38 mm) | 124 | 0° to 155° | 49 | 0.18 | Plastic | Plastic | No | 0.17" (4.3 mm) | IP68; IEC Zone 2 Groups IIC, IIB, IIA | ATEX II 3 G Ex ec IIC Gc, C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component | 0000000 | 000000 |
100-240V AC, Single Phase, 50Hz/60Hz—Wire Leads | ||||||||||||||
4.72" (120 mm) | 4.72" (120 mm) | 1.5" (38 mm) | 124 | 0° to 155° | 49 | 0.18 | Plastic | Plastic | No | 0.17" (4.3 mm) | IP68; IEC Zone 2 Groups IIC, IIB, IIA | ATEX II 3 G Ex ec IIC Gc, C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component | 0000000 | 00000 |
115-230V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminals | ||||||||||||||
3.62" (92 mm) | 3.62" (92 mm) | 1.5" (38 mm) | 50 | 0° to 155° | 43 | 0.08 | Plastic | Plastic | No | 0.17" (4.3 mm) | IP68; IEC Zone 2 Groups IIC, IIB, IIA | ATEX II 3 G Ex nA IIC Gc, C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component | 0000000 | 00000 |
4.72" (120 mm) | 4.72" (120 mm) | 1.5" (38 mm) | 106 | 0° to 155° | 43 | 0.08 | Plastic | Plastic | No | 0.17" (4.3 mm) | IP68; IEC Zone 2 Groups IIC, IIB, IIA | ATEX II 3 G Ex nA IIC Gc, C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component | 0000000 | 00000 |
115-230V AC, Single Phase, 50Hz/60Hz—Wire Leads | ||||||||||||||
2.36" (60 mm) | 2.36" (60 mm) | 0.98" (25 mm) | 19 | 0° to 155° | 31 | 0.04 | Plastic | Plastic | No | 0.17" (4.3 mm) | IP68; IEC Zone 2 Groups IIC, IIB, IIA | ATEX II 3 G Ex nA IIC Gc, C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component | 0000000 | 00000 |
3.62" (92 mm) | 3.62" (92 mm) | 1.5" (38 mm) | 50 | 0° to 155° | 43 | 0.08 | Plastic | Plastic | No | 0.17" (4.3 mm) | IP68; IEC Zone 2 Groups IIC, IIB, IIA | ATEX II 3 G Ex nA IIC Gc, C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component | 0000000 | 00000 |
Oblong | ||||||||||||||
95-264V AC, Single Phase, 50Hz/60Hz—Wire Leads | ||||||||||||||
5.91" (150 mm) | 6.77" (172 mm) | 2.01" (51 mm) | 220 | -4° to 158° | 57 | 0.27 | Aluminum | Plastic | No | 0.16" (4.3 mm) | IP68; IEC Zone 2 Groups IIC, IIB, IIA | ATEX II 3 G Ex nA IIC Gc, C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component | 0000000 | 000000 |
Hazardous Location Equipment-Cooling Fan Kits
Cool electronics and other sensitive equipment in potentially unsafe areas. These fans are non-sparking, so they’re safe for use around gas and explosive dust. They also withstand washdowns, occasional submersion in water, and wet weather. They’re not for use in mines. Ball bearings reduce the heat that’s generated to prolong fan lifespan.
For technical drawings and 3-D models, click on a part number.

Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Depth | Airflow, cfm | Temp. Range, °F | Volume, dBA | Current, A | Frame Material | Mounting Fasteners Included | Mounting Hole Diameter | Environmental Rating | Specifications Met | Each | |
With 304 Stainless Steel Fan Guard | |||||||||||||
120V AC, Single Phase, 50Hz/60Hz—Two Prong Plug | |||||||||||||
4.72" (120 mm) | 4.72" (120 mm) | 1.5" (38 mm) | 106 | 0° to 155° | 43 | 0.08 | Aluminum | No | 0.17" (4.3 mm) | IEC Zone 2 Groups IIC, IIB, IIA, IP68 | ATEX II 3 G Ex nA IIC Gc, C-UL Listed, UL Listed, UL Recognized Component | 0000000 | 0000000 |

Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Depth | Airflow, cfm | Temp. Range, °F | Volume, dBA | Current, A | Frame Material | Mounting Fasteners Included | Mounting Hole Diameter | Environmental Rating | Specifications Met | Each | |
With 304 Stainless Steel Fan Guard | |||||||||||||
120V AC, Single Phase, 50Hz/60Hz—Two Prong Plug | |||||||||||||
5.91" (150 mm) | 6.77" (172 mm) | 2.01" (51 mm) | 220 | 0° to 155° | 57 | 0.23 | Aluminum | No | 0.17" (4.3 mm) | IEC Zone 2 Groups IIC, IIB, IIA, IP68 | ATEX II 3 G Ex nA IIC Gc, C-UL Listed, UL Listed, UL Recognized Component | 0000000 | 0000000 |