Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping. The internal circuits of these air conditioners are rated IP54. The external circuits of these air conditioners are rated IP34.
Air conditioners with 3,600 and 5,100 BTU/hr. cooling capacity require two openings for installation.
Temperature controllers allow you to integrate these air conditioners into your network, or connect them to a computer or PLC, so you can monitor temperatures and manage settings and alarms remotely. An included RJ12 cord connects the adapter to your air conditioner. Two RJ45 cords (not included) are also required: one to connect the adapter to the interface module, and another to connect the interface to your device or network. An included USB cord also allows you to send data to your computer from the interface. Use the brackets to mount these controllers to DIN rail on a panel.
Foam filters catch fine particles and are disposed of after use. Aluminum filters work best in an oily environment and can be repeatedly washed and reused.
Overall | For Opening | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Ht. | Wd. | Mounting Fasteners Included | Includes | Environmental Rating | Specifications Met | Each | |
With Adjustable Thermostat (68° to 131° F) | |||||||||||||
120V AC, Single Phase, 60Hz—Quick-Disconnect Terminals | |||||||||||||
1,000 | 200 | 3.3 | 21 5/8" | 11" | 5 1/2" | 21 5/8" | 11" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 000000000 |
2,000 | 160 | 5.7 | 21 5/8" | 11" | 7 7/8" | 21 5/8" | 11" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
3,600 | 350 | 10 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
5,100 | 470 | 12.5 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
230V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminals | |||||||||||||
1,000 | 200 | 1.7 | 21 5/8" | 11" | 5 1/2" | 21 5/8" | 11" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
2,000 | 155 | 2.6 | 21 5/8" | 11" | 7 7/8" | 21 5/8" | 11" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
3,600 | 350 | 4.4 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
5,100 | 470 | 6 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
8,000 | 575 | 8.5 | 62 3/16" | 15 3/4" | 11 3/8" | 62 1/8" | 15 3/4" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
460V AC, Three Phase, 50Hz/60Hz—Quick-Disconnect Terminals | |||||||||||||
5,100 | 470 | 2.6 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
8,000 | 525 | 3 | 62 3/16" | 15 3/4" | 11 3/8" | 62 1/8" | 15 3/4" | Yes | Mounting Bracket, Mounting Template | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
Material | Includes | Each | |
Plastic | Adapter, RJ12 Adapter Cord, USB Controller Cord | 000000000 | 000000000 |
Top-Mount Enclosure-Cooling Air Conditioners
Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Overall | For Opening | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Ht. | Wd. | Mounting Fasteners Included | Each | |
With Adjustable Thermostat (68° to 131° F) | ||||||||||
120V AC, Single Phase, 60Hz—Quick-Disconnect Terminals | ||||||||||
3,600 | 285 | 8.7 | 16 5/16" | 23 1/2" | 18 3/4" | 15 3/8" | 19 5/16" | Yes | 00000000 | 000000000 |
5,100 | 285 | 14.1 | 16 5/16" | 23 1/2" | 18 3/4" | 15 3/8" | 19 5/16" | Yes | 00000000 | 00000000 |
7,200 | 275 | 14.2 | 16 5/16" | 23 1/2" | 18 3/4" | 15 3/8" | 19 5/16" | Yes | 00000000 | 00000000 |
Remote Control Wall-Mount Enclosure-Cooling Air Conditioners
Keep your equipment cool in hard-to-reach enclosures. These air conditioners include an adapter and temperature controller, so you can monitor temperatures and manage settings and alarms remotely. You can integrate them into your facility's network or a programmable logic controller (PLC). If you'd rather control them from your laptop, use their RJ45 connection (cord not included). Use a bracket to mount the adapter and controller to a DIN rail on a nearby panel.
Air conditioners with a 3,600 or 5,100 Btu/hr. cooling capacity require two openings for installation.
Foam filters catch fine particles and are disposed of after use. Aluminum filters work best in an oily environment and can be repeatedly washed and reused.
Overall | For Opening | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Capacity, Btu/hr. | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Ht. | Wd. | Mounting Fasteners Included | Features | Includes | Each | |
With Adjustable Thermostat (68° F to 131° F) | ||||||||||||
120V AC, Single Phase, 60Hz—Quick-Disconnect Terminals | ||||||||||||
1,000 | 200 | 3.3 | 21 5/8" | 11" | 5 1/2" | 21 5/8" | 11" | Yes | Condensate Drain Tube | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 000000000 |
2,000 | 160 | 5.7 | 21 5/8" | 11" | 7 7/8" | 21 5/8" | 11" | Yes | Condensate Drain Tube, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
3,600 | 350 | 10 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4"; 13 3/4" | Yes | Integrated Condensate Evaporator, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
5,100 | 470 | 12.5 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4"; 13 3/4" | Yes | Integrated Condensate Evaporator, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
230V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminals | ||||||||||||
1,000 | 200 | 1.7 | 21 5/8" | 11" | 5 1/2" | 21 5/8" | 11" | Yes | Condensate Drain Tube | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
2,000 | 155 | 2.6 | 21 5/8" | 11" | 7 7/8" | 21 5/8" | 11" | Yes | Condensate Drain Tube, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
3,600 | 350 | 4.4 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4"; 13 3/4" | Yes | Integrated Condensate Evaporator, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
5,100 | 470 | 6 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4"; 13 3/4" | Yes | Integrated Condensate Evaporator, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
8,000 | 575 | 8.5 | 62 3/16" | 15 3/4" | 11 3/8" | 62 1/8" | 15 3/4" | Yes | Integrated Condensate Evaporator, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
460V AC, Three Phase, 50Hz/60Hz—Quick-Disconnect Terminals | ||||||||||||
5,100 | 470 | 2.6 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4"; 13 3/4" | Yes | Integrated Condensate Evaporator, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
8,000 | 525 | 3 | 62 3/16" | 15 3/4" | 11 3/8" | 62 1/8" | 15 3/4" | Yes | Integrated Condensate Evaporator, Programmable Alarm, Temperature Display | Adapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller Cord | 0000000 | 00000000 |
Washdown Enclosure-Cooling Air Conditioners
Suitable for washdown applications, these air conditioners are rated NEMA 4X to resist dirt, washdowns, and corrosion. Use them to protect equipment in enclosures and cabinets from overheating with chilled air. The internal circuits of these air conditioners are rated IP55. The external circuits of these air conditioners are rated IP34.
Overall | For Opening | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Ht. | Wd. | For Use Outdoors | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
With Adjustable Thermostat (68° to 131° F) | |||||||||||||
120V AC, Single Phase, 60Hz—Quick-Disconnect Terminals | |||||||||||||
1,700 | 160 | 5.7 | 24 3/8" | 11 3/16" | 11 11/16" | 21 5/8" | 11" | Yes | Yes | IP34, IP55, NEMA 4X | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 000000000 |
3,600 | 350 | 10 | 40 3/16" | 15 7/8" | 14 1/8" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Yes | IP34, IP55, NEMA 4X | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats
Cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Diameter | Height | For Opening Diameter | Includes | Each | Each | ||
With Adjustable Thermostat (-50° to 200° F) | ||||||||||||||||
304 Stainless Steel—IP24, NEMA 3R | ||||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 64 | 120V AC | Wire Leads | 1 1/8" | 6 1/2" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 0000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 66 | 120V AC | Wire Leads | 1 1/8" | 6 1/2" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 72 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 73 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 74 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 76 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
Low-Noise Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats
Quietly cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. Using compressed air, they’re a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Diameter | Height | For Opening Diameter | Includes | Each | Each | ||
With Adjustable Thermostat (-50° to 200° F) | ||||||||||||||||
304 Stainless Steel—IP24, NEMA 3R | ||||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 58 | 120V AC | Wire Leads | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 000000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 60 | 120V AC | Wire Leads | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 67 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 68 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 68 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 69 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
Weather-Resistant Enclosure-Cooling Vortex Tubes
Cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Diameter | Height | For Opening Diameter | Environmental Rating | Includes | Each | Each | ||
304 Stainless Steel—IP24, NEMA 3R | |||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 64 | 1 1/8" | 6 1/2" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 0000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 66 | 1 1/8" | 6 1/2" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 72 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 73 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 74 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 76 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
Low-Noise Weather-Resistant Enclosure-Cooling Vortex Tubes
Quietly cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. They use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Diameter | Height | For Opening Diameter | Includes | Each | Each | ||
304 Stainless Steel—IP24, NEMA 3R | ||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 58 | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 0000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 60 | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 67 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 68 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 68 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 67 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
Enclosure Thermostats for Multiple Devices
Keep electronics in your enclosure from getting too hot or cold with these thermostats that control two devices at once. Clip them to a DIN rail to install.
Nonadjustable thermostats prevent tampering and accidental changes. Adjustable thermostats allow you to set custom temperatures.
Heating and cooling thermostats control heaters and fans or air conditioners. Thermostats with one actuation point, also known as changeover thermostats, switch between heating and cooling so one device is always running. When the temperature in your enclosure gets hotter than the temperature you set, the thermostat will turn on your fan or air conditioner. It goes back to heating once the temperature is reduced by the temperature difference. So for a thermostat with a temperature difference of 9° F, setting it at 60° F means it will heat the enclosure until it reaches 60° F, switch to cooling until it reaches 51° F, and then switch back to heating.
Heating and cooling thermostats with two actuation points control two devices independently. When your enclosure temperature is within the set range, neither device is powered, so they’re more efficient than changeover thermostats. For each device, temperature setting is the high end of the temperature range, and temperature difference is the size of the range. For a thermostat with temperature settings of 59° and 95° F and an 18° F temperature difference, the heater will switch on when your enclosure is colder than 41° F and turn off when it reaches 59° F. The fan or other cooling device will switch on when the temperature goes above 95° F and turn off once the enclosure cools to 77° F.
Cooling thermostats regulate two cooling devices, such as a fan and an air conditioner, for two-stage cooling. Use only one device for cooling in mild temperatures or both for extreme heat. These thermostats switch your equipment on when the enclosure is hotter than the temperature setting. Once the temperature is reduced by the temperature difference, it will switch off. For example, a thermostat set at 77° F for a fan and 140° F for an air conditioner will power both devices when the enclosure is over 140° F. With a temperature difference of 18° F, the air conditioner will switch off when the temperature goes below 122° F. The fan will run until the temperature reaches 59° F, and switch back on if it heats up to 77° F or hotter.
All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked. They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch on fire and won’t spread the fire by dripping. Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
Temperature | Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Setting, °F | Difference, °F | Tolerance, °F | Voltage | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Adjustable | ||||||||||
40° to 140° | 9° | -5.4° to 3.6° | 120V AC | 2 5/8" | 2" | 1 1/2" | IP20 | CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
40° to 140° | 9° | -5.4° to 3.6° | 240V AC | 2 5/8" | 2" | 1 1/2" | IP20 | CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Heating Temperature | Cooling Temperature | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Setting | Difference | Tolerance | Setting | Difference | Tolerance | Voltage | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Nonadjustable | |||||||||||||
59° F/15° C | 18° F/10° C | ±9° F/±5° C | 95° F/35° C | 18° F/10° C | ±12.6° F/±7° C | 120V AC/240V AC 24V DC to 75V DC | 1 7/8" | 2 1/2" | 1 5/16" | IP20 | CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0, VDE Certified | 0000000 | 000000 |
59° F/15° C | 18° F/10° C | ±9° F/±5° C | 122° F/50° C | 18° F/10° C | ±12.6° F/±7° C | 120V AC/240V AC 24V DC to 75V DC | 1 7/8" | 2 1/2" | 1 5/16" | IP20 | CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0, VDE Certified | 0000000 | 00000 |
77° F/25° C | 18° F/10° C | ±9° F/±5° C | 122° F/50° C | 18° F/10° C | ±12.6° F/±7° C | 120V AC/240V AC 24V DC to 75V DC | 1 7/8" | 2 1/2" | 1 5/16" | IP20 | CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0, VDE Certified | 0000000 | 00000 |
Adjustable | |||||||||||||
14° F to 122° F | 12.6° F | ±7° F | 68° F to 176° F | 12.6° F | ±7° F | 120V AC/240V AC | 2 5/8" | 2" | 1 13/16" | IP20 | CSA Certified, CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0, VDE Certified | 0000000 | 00000 |
32° F to 140° F | 12.6° F | ±7° F | 32° F to 140° F | 12.6° F | ±7° F | 120V AC/240V AC | 2 5/8" | 2" | 1 13/16" | IP20 | CSA Certified, CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0, VDE Certified | 0000000 | 00000 |
Cooling Temperature | Cooling Temperature | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Setting | Difference | Tolerance | Setting | Difference | Tolerance | Voltage | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Nonadjustable | |||||||||||||
122° F/50° C | 18° F/10° C | ±12.6° F/±7° C | 140° F/60° C | 18° F/10° C | ±12.6° F/±7° C | 120V AC/240V AC 24V DC to 75V DC | 1 7/8" | 2 1/2" | 1 5/16" | IP20 | CE Marked, VDE Certified, C-UL Recognized Component, UL 94 V-0, UL Recognized Component | 0000000 | 000000 |
Adjustable | |||||||||||||
32° F to 140° F | 12.6° F | ±7° F | 32° F to 140° F | 12.6° F | ±7° F | 120V AC/240V AC | 2 5/8" | 2" | 1 13/16" | IP20 | CSA Certified, CE Marked, VDE Certified, C-UL Recognized Component, UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
Enclosure Thermostats
Control a single heating or cooling device in your enclosure to keep electronics at a safe operating temperature. Clip them on to a DIN rail and connect them to your heater, fan, or air conditioner.
All these thermostats meet American, Canadian, or European safety standards. They have an IP20 rating—to prevent shocks, fingers won’t fit inside. They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
Adjustable thermostats let you set the temperature you need. Nonadjustable thermostats have a fixed temperature setting to prevent tampering or accidental changes.
These thermostats keep the air in your enclosure within a set range. Temperature setting is the high end of the range for both heating and cooling thermostats. Heating thermostats are normally closed—when the air in your enclosure reaches the temperature setting, the thermostat will turn the heater off. Cooling thermostats are normally open, so they’ll switch your fan or air conditioner on when the air in your enclosure reaches the temperature setting.
Temperature difference is the difference between the temperature when the thermostat turns your device on and when it turns off. For a heater thermostat with a temperature setting of 50° and an 18° temperature difference, the thermostat will switch your heater on when the temperature goes below 32° and off once the temperature reaches 50°. Thermostats with a lower temperature difference maintain a narrower range of temperatures, but they use more power because they switch on and off more frequently.
Temperature | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Setting | Difference | Tolerance | Voltage | Current, A | For DIN Rail Ht., mm | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
For Cooling | ||||||||||||
Adjustable | ||||||||||||
14° to 122° F | 12.6° F | ±7° F | 120V AC/240V AC | 16 | 35 | 2.4" | 1.3" | 1.6" | IP20 | CE Marked, CSA Certified, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 0000000 | 000000 |
32° to 140° F | 12.6° F | ±7° F | 120V AC/240V AC | 16 | 35 | 2.4" | 1.3" | 1.6" | IP20 | CE Marked, CSA Certified, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 00000000 | 00000 |
Nonadjustable | ||||||||||||
95° F/35° C | 18° F/10° C | ±11° F/±6° C | 120V AC/240V AC 24V DC to 75V DC | 16 | 35 | 1 7/8" | 1 5/16" | 1 5/16" | IP20 | CE Marked, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 0000000 | 00000 |
122° F/50° C | 18° F/10° C | ±11° F/±6° C | 120V AC/240V AC 24V DC to 75V DC | 16 | 35 | 1 7/8" | 1 5/16" | 1 5/16" | IP20 | CE Marked, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 0000000 | 00000 |