About Air Preparation
More
Water-Cooled Compressed Air Aftercoolers
Connect these aftercoolers to a cold-water line to chill hot air coming from a compressor—no electricity needed. Cooling the air condenses water for removal from your compressed air system. Install a separator (not included) after your aftercooler to collect and discharge water.
Air Inlet (Female) | Air Outlet (Female) | Water Inlet (Female) | Water Outlet (Female) | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Pipe Size | Thread Type | Pipe Size | Thread Type | Pipe Size | Thread Type | Max. Pressure, psi | Max. Flow Rate @ psi | Required Water Flow @ Airflow | Max. Temp., °F | Cools Air Within | Ht. | Wd. | Lg. | Each | |
Inline | |||||||||||||||||
1 1/2 | NPT | 1 1/2 | NPT | 1/2 | NPT | 1/2 | NPT | 250 | 150 scfm @ 100 | 3 gpm @ 100 scfm | 350° | 15° F of Inlet Water | 3 1/2" | 2 5/8" | 51 3/8" | 00000000 | 0000000 |
1 1/2 | NPT | 1 1/2 | NPT | 1/2 | NPT | 1/2 | NPT | 250 | 40 scfm @ 100 | 3 gpm @ 100 scfm | 350° | 15° F of Inlet Water | 3 1/2" | 2 5/8" | 33 3/8" | 00000000 | 000000 |
1 1/2 | NPT | 1 1/2 | NPT | 1/2 | NPT | 1/2 | NPT | 250 | 80 scfm @ 100 | 3 gpm @ 100 scfm | 350° | 15° F of Inlet Water | 3 1/2" | 2 5/8" | 42 3/8" | 00000000 | 000000 |
2 1/2 | NPT | 2 1/2 | NPT | 1 | NPT | 1 | NPT | 250 | 310 scfm @ 100 | 3 gpm @ 100 scfm | 350° | 15° F of Inlet Water | 6 1/4" | 5 1/4" | 50 1/2" | 00000000 | 00000000 |
Fan-Cooled Compressed Air Aftercoolers
These aftercoolers have a fan that chills hot air coming from a compressor. Cooling the air condenses water for removal from your compressed air system. Install a separator (not included) after your aftercooler to collect and discharge water.
For technical drawings and 3-D models, click on a part number.
Air Inlet | Air Outlet | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Flow Rate @ psi | Max. Temp., °F | Cools Air Within | Ht. | Wd. | Dp. | hp | Each | |
Ceiling-, Floor-, and Wall-Mount | |||||||||||||||
Single Phase, 115-230V AC | |||||||||||||||
1 | NPT | Female | 1 | NPT | Female | 250 | 50 scfm @ 80 | 350° | 15° F of Ambient Air | 12 7/8" | 19 1/2" | 13 3/4" | 1/3 | 0000000 | 000000000 |
1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 250 | 100 scfm @ 80 | 350° | 15° F of Ambient Air | 13 1/4" | 19 1/2" | 15 1/8" | 1/3 | 0000000 | 00000000 |
1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 250 | 200 scfm @ 80 | 350° | 15° F of Ambient Air | 17 1/4" | 23 1/4" | 16 1/4" | 1/2 | 0000000 | 00000000 |