Extended-Life Plastic Circulation Pumps for Chemicals
These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Maintenance Kits | Replacement Impellers | |||||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Viscosity, cP | hp | Current, A | Intake (Gender) | Discharge (Gender) | Lg. | Wd. | Ht. | Each | Each | Each | |||
120V AC, 240V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
23 | __ | 20 | 10 | __ | __ | __ | 35 | __ | 1/4 | 2.07/4.14 | 1 (Female) | 1 (Female) | 14 3/8" | 5 1/8" | 7 7/8" | 0000000 | 000000000 | 00000000 | 000000 | 00000000 | 0000000 |
26 | __ | 26 | 12 | __ | __ | __ | 35 | __ | 1/3 | 3.24/6.84 | 1 (Female) | 1 (Female) | 16 5/16" | 6 1/8" | 8 3/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
57 | 57 | 53 | 30 | 25 | __ | __ | 45 | __ | 1/2 | 1.1/2.2 | 1 1/2 (Female) | 1 1/2 (Female) | 18 3/8" | 8 7/8" | 11 5/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
90 | 90 | 84 | 74 | 61 | 49 | __ | 70 | __ | 1 | 1.5/3 | 1 1/2 (Female) | 1 1/2 (Female) | 18 7/8" | 6 5/16" | 10 1/8" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
120V AC, 208–240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 9.2/6.3-4.6 | 1 1/2 (Female) | 1 (Male) | 17 13/16" | 9 1/8" | 8 3/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
208–240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
30 | 31 | 26 | 20 | 7 | __ | __ | 41 | 5 | 1/3 | 0.6/1.3-1.2 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/4" | 7 3/8" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 1.7/1.7-0.8 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/8" | 7 3/16" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 1.1/3.3-2.2 | 1 1/2 (Female) | 1 (Male) | 16 9/16" | 9 1/8" | 7 3/8" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
82 | 82 | 82 | 81 | 80 | 71 | 61 | 85 | 5 | 2 | 2.4/4.9-4.8 | 2 (Male) | 1 1/2 (Male) | 20 11/16" | 10 3/8" | 10" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
120 | 120 | 120 | 120 | 112 | 105 | 92 | 95 | 5 | 3 | 3.9/8-7.8 | 2 (Male) | 1 1/2 (Male) | 24 3/8" | 11 1/2" | 10 1/2" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
Stainless Steel Circulation Pumps for Chemicals
A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Replacement Impellers | |||||||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | @ 70 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Solids Dia. | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||||
Hardwire | |||||||||||||||||||||||
32 | __ | 22 | 10 | __ | __ | __ | 44 | 100 | 1/8" | 50 | 1/3 | 5.6/2.8 | 3/4 | Female | 1/2 | Female | 15" | 9" | 7 1/2" | 0000000 | 0000000 | 0000000 | 0000000 |
32 | __ | 32 | 32 | 20 | __ | __ | 62 | 100 | 3/32" | 50 | 3/4 | 10.6/5.3 | 1 1/4 | Female | 3/4 | Female | 16" | 9" | 7 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
36 | __ | 30 | 22 | __ | __ | __ | 54 | 100 | 1/8" | 50 | 1/2 | 7.6/3.8 | 3/4 | Female | 1/2 | Female | 15" | 9" | 7 1/2" | 0000000 | 000000 | 0000000 | 000000 |
38 | __ | 33 | 27 | 18 | __ | __ | 59 | 100 | 1/8" | 50 | 3/4 | 10.6/5.3 | 3/4 | Female | 1/2 | Female | 15" | 9" | 7 1/2" | 0000000 | 000000 | 0000000 | 000000 |
90 | 82 | 63 | 35 | __ | __ | __ | 60 | 100 | 3/32" | 50 | 1 | 12.6/6.3 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
240/460V AC, Three Phase—With Thermal Overload Protection | |||||||||||||||||||||||
Hardwire | |||||||||||||||||||||||
75 | 47 | 15 | __ | __ | __ | __ | 34 | 100 | 3/16" | 50 | 1 | 2.9/1.4 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
95 | 80 | 55 | 20 | __ | __ | __ | 49 | 100 | 3/16" | 50 | 1 1/2 | 3.9/2 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
110 | 100 | 80 | 58 | 28 | __ | __ | 70 | 100 | 3/32" | 50 | 1 1/2 | 3.9/2 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
115 | __ | __ | 55 | __ | __ | __ | 52 | 100 | 3/16" | 50 | 2 | 5.3/2.7 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
130 | __ | __ | __ | 90 | 60 | __ | 82 | 100 | 3/32" | 50 | 2 | 5.3/2.7 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
130 | __ | __ | __ | 95 | 55 | __ | 79 | 100 | 3/16" | 50 | 3 | 7.6/3.8 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
140 | __ | __ | __ | __ | 85 | 55 | 88 | 100 | 3/32" | 50 | 3 | 7.6/3.8 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
Self-Priming Stainless Steel Circulation Pumps for Chemicals
Self-priming up to 6 ft., these pumps have a stainless steel housing sealed with PTFE to resist chemicals such as ammonia and detergents as well as harsh solvents including methyl ethyl ketone (MEK). The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
1 | 68 | 54 | 41 | __ | __ | __ | 50 | 75 | 20 | 3/4 | 9/5 | 1 1/2 | Female | 1 1/2 | Female | 15 3/4" | 8 3/4" | 9 1/2" | 0000000 | 000000000 |
2 | 100 | __ | 65 | 45 | __ | __ | 50 | 75 | 20 | 1 1/2 | 18/9 | 1 1/2 | Female | 1 1/2 | Female | 16 1/2" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
3 | 68 | 54 | 41 | __ | __ | __ | 50 | 75 | 20 | 3/4 | 3/2 | 1 1/2 | Female | 1 1/2 | Female | 15 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
4 | 100 | __ | 65 | 45 | __ | __ | 50 | 75 | 20 | 1 1/2 | 5/3 | 1 1/2 | Female | 1 1/2 | Female | 16 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
5 | 132 | __ | __ | 82 | 60 | 14 | 63 | 75 | 20 | 2 | 6/3 | 1 1/2 | Female | 1 1/2 | Female | 17 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
Impellers for Circulation Pumps
Match your pump’s manufacturer and model number to choose the right replacement impeller.
For Pump Model Number | For Pump Part Number | Kit Number | Each | |
AMT Pump Company | ||||
---|---|---|---|---|
__ | 3680-975-97, 5160-975-97 | 3680-015-09 | 0000000 | 0000000 |
__ | 3696-975-97 | 3696-013-98 | 00000000 | 000000 |
2761-95 | 2761-95 | 2820-011-0B | 000000000 | 00000 |
2762-95, 276B-95 | 2762-95, 276B-95 | 2820-011-09 | 000000000 | 00000 |
2764-95, 276D-95 | 2764-95, 276D-95 | 2820-011-0A | 000000000 | 00000 |
276C-95 | 276C-95 | 2820-011-0C | 000000000 | 00000 |
282A-95 | 282A-95 | 2820-011-05 | 000000000 | 00000 |
282B-95 | 282B-95 | 2820-011-06 | 000000000 | 00000 |
282C-95 | 282C-95 | 2820-011-03 | 000000000 | 00000 |
282D-95 | 282D-95 | 2820-011-01 | 000000000 | 00000 |
282E-95 | 282E-95 | 2820-011-07 | 000000000 | 00000 |
282F-95 | 282F-95 | 2820-011-02 | 000000000 | 00000 |
282K-95 | 282K-95 | 2820-011-04 | 000000000 | 00000 |
282M-95 | 282M-95 | 2820-011-08 | 000000000 | 00000 |
2851-95, 285E-95 | 2851-95, 285E-95 | 2850-010-01 | 000000000 | 00000 |
2852-95, 285F-95 | 2852-95, 285F-95 | 2850-010-03 | 000000000 | 00000 |
2853-95, 285G-95 | 2853-95, 285G-95 | 2850-010-05 | 000000000 | 00000 |
2855-95, 285H-95 | 2855-95, 285H-95 | 2850-010-07 | 000000000 | 00000 |
285J-95 | 285J-95 | 2850-010-06 | 000000000 | 00000 |
285K-95 | 285K-95 | 2850-010-08 | 000000000 | 00000 |
285P-95 | 285P-95 | 2850-010-04 | 000000000 | 00000 |
2874-95 | 2874-95 | 2874-013-90 | 00000000 | 000000 |
2875-95 | 2875-95 | 2875-013-90 | 00000000 | 000000 |
2876-95 | 2876-95 | 2876-013-90 | 000000000 | 000000 |
Anderson Process | ||||
AM Series | TM2FE-ER-VT-076-AA | TM-M3L23E-Z | 00000000 | 000000 |
AM Series | TM2GE-ER-VT-090-AA | TM-M5L02E-Z | 00000000 | 000000 |
AMX Series | TM4HC-EC-VT-090-BA | TM-X0L05EC | 00000000 | 000000 |
AMX Series | TM4KC-EC-VT-108-BA | TM-X1L05EC | 00000000 | 000000 |
AMX Series | TM6LC-EC-VT-123-BA | TM-X2L05EC | 00000000 | 000000 |
AMX Series | TM6MC-EC-VT-135-BA | TM-X3L05EC | 00000000 | 000000 |
Finish Thompson | ||||
AC | AC4STS1V300B015C05, AC5RTS1V300B015C13 | A102105-1 | 0000000 | 000000 |
AC | AC4STS1V320B015C08 | A102105-2 | 0000000 | 000000 |
AC | AC4STS1V350B015C15, AC5RTS1V350B015C22 | A102105-3 | 0000000 | 000000 |
AC | AC5RTS2V370B015C24 | A102105-4 | 0000000 | 000000 |
AC | AC5RTS2V450B015C25 | A102105-5 | 0000000 | 000000 |
AC | AC5STS1V400B015C12, AC5STS2V400B015C06 | A102114-1 | 0000000 | 000000 |
AC | AC5STS1V420B015C22 | A102114-2 | 0000000 | 000000 |
AC | AC5STS3V458B015C24 | A102114-11 | 0000000 | 000000 |
AC | AC5STS3V478B015C25 | A102114-12 | 0000000 | 000000 |
Goulds Pumps | ||||
1GD, 3888D3, 3888D4, 3SD, 3SDX, 4SD, 4SDX | __ | 4K11 | 0000000 | 00000 |
GT | __ | 2K713 | 0000000 | 00000 |
Graymills | ||||
IMS, IMV | IMS08-E, IMS08-F, IMV08-E, IMV08-F | 785-91346 | 0000000 | 00000 |
IMS, IMV | IMS100-F, IMS75-F, IMV100-F, IMV75-F | 785-91356 | 0000000 | 000000 |
IMS, IMV | IMS25-E, IMS25-F, IMV25-E, IMV25-F | 785-91351 | 0000000 | 00000 |
IMS, IMV | IMS50-E, IMS50-F, IMV50-E, IMV50-F | 785-91354 | 0000000 | 00000 |
VPJ | VPJ310-A, VPJ310-B, VPJ35-A, VPJ35-B, VPJ38-A, VPJ38-B | 401-37405 | 0000000 | 000000 |
MP Pumps | ||||
S110C | 25173 | 25021 | 0000000 | 000000 |
S130C | 22730 | 22628 | 0000000 | 000000 |
S130C | 27756 | 25020 | 0000000 | 000000 |
S200C | 22729 | 22689 | 0000000 | 000000 |
S200C | 22737 | 22686 | 0000000 | 000000 |
S30C | 22731 | 22573 | 0000000 | 000000 |
S30C | 22746 | 22143 | 0000000 | 000000 |
S30C | 24189 | 22138 | 0000000 | 000000 |
S60C | 27669 | 27662 | 0000000 | 000000 |
S60C | 27672 | 27663 | 0000000 | 00000000 |
S60C | 27675 | 27664 | 0000000 | 000000 |
S80C | 26539 | 25668 | 0000000 | 000000 |
S80C | 26622 | 26585 | 0000000 | 000000 |
MTH Pumps | ||||
T41 | T41B-AB | BK4100 | 000000000 | 000000 |
T41 | T41C-AB | BK4101 | 000000000 | 000000 |
T41 | T41D-AB | BK4102 | 000000000 | 000000 |
T41 | T41G-AB | BK4104 | 000000000 | 000000 |
T41 | T41J-AB | BK4105 | 000000000 | 000000 |
March | ||||
Series 4 & 5 | TE-5C-MD | 0150-0148-0200 | 0000000 | 000000 |
Series 5.5 | 0151-0027-0300, 0151-0027-0900 | 0151-0046-0300 | 00000000 | 000000 |
Series 6 | 0153-0002-0400, 0153-0002-0500 | 0153-0043-0500 | 00000000 | 000000 |
Series 7 | 0155-0173-0200, 0155-0174-0200 | 0155-0160-0200 | 00000000 | 000000 |
Series 7 & 7.5 | TE-7R-MD | 0155-0165-0100 | 0000000 | 000000 |
Series 7.5 | 0156-0001-0100 | 0156-0004-0200 | 00000000 | 00000000 |
Series 8 | 0157-0008-0200 | 0157-0050-0500 | 00000000 | 00000000 |
RS Corcoran | ||||
2000D | 2DAA05.33-3.25 | 2003D-0325 | 00000000 | 000000 |
2000D | 2DAA05.5-3.75, 2DAA05.52-3.75 | 2003D-0375 | 00000000 | 000000 |
2000D | 2DAA1-4, 2DAA13-4 | 2003D-0400 | 00000000 | 000000 |
2000D | 2DAA1.5-4.44, 2DAB3-4.44 | 2003D-0444 | 00000000 | 000000 |
2000D | 2DAB2-4.25 | 2003D-0425 | 00000000 | 000000 |
Thomsen | ||||
No. 4 | 41021-DA, 41521-DA | 9400-67 | 0000000 | 000000 |
No. 4 | 42021-EA | 9397-67 | 0000000 | 000000 |
No. 4 | 42521-GA | 9395-67 | 0000000 | 000000 |
No. 5 | 50321-KA, 50421-KA | 9405-67 | 0000000 | 000000 |
Maintenance Kits for Circulation Pumps
Keep your circulation pump in working order by replacing broken or worn parts. Match the pump’s manufacturer and model number to choose the right kit.
For Pump Model Number | For Pump Part Number | Kit Number | Each | |
AMT Pump Company | ||||
---|---|---|---|---|
__ | 3680-975-97, 5160-975-97 | 3680-015-09 | 0000000 | 000000 |
__ | 3696-975-97 | 3696-013-98 | 0000000 | 00000 |
2821-95, 2825-95, 2827-95 | 2821-95, 2825-95, 2827-95 | 2820-304-95 | 00000000 | 00000 |
Anderson Process | ||||
AM Series | TM2FE-ER-VT-076-AA | TM-RG241V | 00000000 | 00000 |
AM Series | TM2GE-ER-VT-090-AA | TM-RG244V | 00000000 | 00000 |
AMX Series | TM4HC-EC-VT-090-BA | TM-RG356V | 00000000 | 00000 |
AMX Series | TM4KC-EC-VT-108-BA | TM-RG362V | 00000000 | 00000 |
AMX Series | TM6LC-EC-VT-123-BA, TM6MC-EC-VT-135-BA | TM-RG368V | 00000000 | 00000 |
Finish Thompson | ||||
AC | AC4STS1V300B015C05, AC4STS1V320B015C08, AC4STS1V350B015C15 | A102174 | 0000000 | 000000 |
AC | AC5RTS1V300B015C13, AC5RTS1V350B015C22, AC5RTS2V370B015C24, AC5RTS2V450B015C25, AC5STS1V400B015C12, AC5STS1V420B015C22, AC5STS2V400B015C06, AC5STS3V458B015C24, AC5STS3V478B015C25 | A102147 | 0000000 | 000000 |
Graymills | ||||
IMS | IMS08-E, IMS08-F, IMS25-E, IMS25-F | 02-9551-51 | 00000000 | 00000 |
IMS | IMS100-F, IMS50-E, IMS50-F, IMS75-F | 785-92480 | 00000000 | 000000 |
MTH Pumps | ||||
T41 | T41B-AB, T41C-AB, T41G-AB, T41J-AB | SK4100 | 000000000 | 000000 |
March | ||||
Series 5.5, Series 6 | 0151-0027-0300, 0151-0027-0900, 0153-0002-0400, 0153-0002-0500 | 0153-0015-1000 | 00000000 | 0000 |
Series 7 | 0155-0173-0200, 0155-0174-0200 | 0155-0010-1000 | 00000000 | 00000 |
Series 7.5 | 0156-0001-0100 | 0156-0010-1000 | 00000000 | 00000 |
Series 8 | 0157-0008-0200 | 0157-0011-1000 | 00000000 | 00000 |
RS Corcoran | ||||
2000D | 2DAA05.33-3.25, 2DAA05.5-3.75, 2DAA05.52-3.75, 2DAA1-4, 2DAA1.5-4.44, 2DAA13-4, 2DAB2-4.25, 2DAB3-4.44 | M0830-1007V | 00000000 | 000000 |
Circulation Pumps for Fuel and Flammable Liquid
Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 7.4/3.7 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 2.4-2.2/1.1 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
100 | __ | 78 | 48 | 10 | 64 | 150 | 264 | 1 | 2.8/1.4 | 1 1/2 | 1 | 15 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
15 | __ | 10 | 4 | __ | 46 | 150 | 264 | 1/3 | 4.8/2.4 | 3/4 | 1/2 | 15 1/2" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
100 | 78 | 64 | 48 | 10 | 64 | 150 | 264 | 1 | 12/6 | 1 1/2 | 1 | 17 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
115 | __ | 100 | 90 | 60 | 81 | 150 | 264 | 1 1/2 | 5-4.6/2.3 | 1 1/2 | 1 | 16 3/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
125 | 114 | 98 | 78 | 18 | 69 | 150 | 264 | 2 | 5.7-5.4/2.7 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
140 | __ | __ | 120 | 47 | 75 | 150 | 264 | 3 | 8.1-7.6/3.8 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Harsh-Environment Low-Maintenance Plastic
Circulation Pumps for Water and Coolants
These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. The impeller is turned with magnets to eliminate seal wear and leakage for a long service life. Pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | @ 20 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
10 | __ | 6 | __ | 16.3 | 7 | 20 | 1/25 | 1.3 | 1/2 | Female | 1/2 | Male | 9" | 4" | 5" | 00000000 | 0000000 | 000000 | 00 |
14 | __ | 12 | 4 | 24.3 | 10 | 20 | 1/10 | 1.7 | 1 | Female | 1/2 | Male | 10 7/8" | 5 1/2" | 5" | 00000000 | 000000 | 000000 | 00 |
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
18 | 17 | 15 | 11 | 29 | 50 | 5 | 1/5 | 2.6/1.3 | 1 | Female | 1/2 | Male | 12 1/4" | 7 1/4" | 7" | 0000000 | 000000 | 0000000 | 0000000 |
High-Flow Harsh-Environment Low-Maintenance
Plastic Circulation Pumps for Water and Coolants
A powerful motor provides twice the flow rate of other extended-life circulation pumps. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Magnets turn the impeller to eliminate seal wear and leakage for a long service life. These pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
32 | 25 | 19 | __ | __ | 40.5 | 17 | 1/3 | 5/2.5 | 1 | Female | 3/4 | Male | 16 1/4" | 8 7/8" | 7" | 00000000 | 000000000 |
38 | 32 | 28 | 21 | __ | 51 | 21 | 1/2 | 9.4/4.7 | 1 | Female | 3/4 | Male | 16 1/4" | 8 7/8" | 7" | 00000000 | 00000000 |
53 | 42 | 37 | 28 | 18 | 58.9 | 25 | 3/4 | 11.8/5.9 | 1 1/2 | Female | 1 | Male | 17 1/4" | 8 5/8" | 8 1/2" | 00000000 | 00000000 |
240/460V AC, Three Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
38 | 32 | 28 | 21 | __ | 51 | 21 | 1/2 | 1.8/0.9 | 1 | Female | 3/4 | Male | 15 1/4" | 8 3/4" | 7" | 00000000 | 00000000 |
53 | 42 | 37 | 28 | 18 | 58.9 | 25 | 3/4 | 2.9/1.5 | 1 1/2 | Female | 1 | Male | 17 1/4" | 8 5/8" | 8 5/8" | 00000000 | 00000000 |
Circulation Pumps for Food and Beverage
Commonly used in food, beverage, and dairy processing, these pumps are 3-A certified to meet sanitary design standards. They have quick-clamp intake and discharge connections to facilitate cleaning. The discharge connection rotates 360° for easy connection to your line. Motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (Female) | Discharge (Female) | Overall | Replacement Impellers | ||||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Tube Connection Type | For Tube OD | Tube Connection Type | For Tube OD | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
80 | 80 | 50 | __ | __ | 33 | 14 | 400 | 1/2 | 7.4/3.7 | Quick-Clamp | 1 1/2" | Quick Clamp | 1 1/2" | 16 1/2" | 6 1/2" | 8 1/4" | 00000000 | 000000000 | 0000000 | 0000000 |
70 | __ | 70 | 40 | __ | 40 | 21 | 700 | 1 | 11.8/5.9 | Quick-Clamp | 1 1/2" | Quick Clamp | 1 1/2" | 17 1/2" | 6 1/2" | 7 1/4" | 00000000 | 00000000 | 0000000 | 000000 |
208-240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
80 | 80 | 50 | __ | __ | 33 | 14 | 400 | 1/2 | 2/1 | Quick-Clamp | 1 1/2" | Quick Clamp | 1 1/2" | 15 7/8" | 6 1/2" | 8 1/4" | 00000000 | 00000000 | 0000000 | 000000 |
70 | __ | 70 | 40 | __ | 40 | 21 | 700 | 1 | 3.6/1.8 | Quick-Clamp | 1 1/2" | Quick Clamp | 1 1/2" | 15 5/8" | 6 1/2" | 7 1/4" | 00000000 | 00000000 | 0000000 | 000000 |
85 | __ | __ | __ | 50 | 44 | 24 | 800 | 1 1/2 | 4-3.8/1.9 | Quick-Clamp | 1 1/2" | Quick Clamp | 1 1/2" | 16 1/4" | 6 1/2" | 7 1/4" | 00000000 | 00000000 | 0000000 | 000000 |
95 | __ | __ | 95 | __ | 62 | 33 | 600 | 2 | 5.3-5/2.5 | Quick-Clamp | 1 1/2" | Quick Clamp | 1 1/2" | 17 1/2" | 6 1/2" | 7 1/4" | 00000000 | 00000000 | 0000000 | 000000 |
Baseplates for Circulation Pumps
Extend the service life of your pump by mounting it to a baseplate. These heavy duty plates minimize vibration and raise the pump off the floor, preventing damage to the motor from flooding or spills.
For technical drawings and 3-D models, click on a part number.
Overall | |||||
---|---|---|---|---|---|
Material | Lg. | Wd. | Ht. | Each | |
For 56C NEMA Frame | |||||
316 Stainless Steel | 24" | 10" | 2 1/2" | 000000 | 0000000 |
Fiberglass | 13" | 9 1/2" | 2 1/2" | 000000 | 000000 |
Fiberglass | 24" | 8 1/2" | 2 3/4" | 000000 | 000000 |
Fiberglass | 24" | 10" | 2 3/4" | 000000 | 000000 |
For 143TC, 145TC NEMA Frame | |||||
316 Stainless Steel | 30 1/2" | 12" | 2 1/2" | 000000 | 000000 |
Fiberglass | 30 1/2" | 12" | 2 3/4" | 000000 | 000000 |
For 182TC, 184TC NEMA Frame | |||||
316 Stainless Steel | 39" | 12" | 2 1/2" | 000000 | 000000 |
Fiberglass | 39" | 12" | 2 3/4" | 000000 | 000000 |