Fuse Blocks for Midget Fuses
Designed for use with non-UL Class midget fuses, these are more compact than fuse blocks for standard size fuses.
Quick-Disconnect | |||||||
---|---|---|---|---|---|---|---|
For No. of Fuses | For Fuse Current, A | Voltage | Tab Wd. | Terminal Current, A | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: ATM, ATQ, BAF, BBS, BLF, BLS, FLM, FLQ, FNM, FNQ, KLK, KTK, KTQ, OTM, SBS, TRM | |||||||
1 | 1/10-30 | 600V AC | 0.25" | 20 | UL Recognized Component, CSA Certified | 0000000 | 000000 |
2 | 1/10-30 | 600V AC | 0.25" | 20 | UL Recognized Component, CSA Certified | 0000000 | 00000 |
3 | 1/10-30 | 600V AC | 0.25" | 20 | UL Recognized Component, CSA Certified | 0000000 | 00000 |
Fuse Blocks for UL Class Fuses
For technical drawings and 3-D models, click on a part number.
For Fuse | Quick-Disconnect | ||||||||
---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | UL Class | Current, A | Voltage | Wire Connection Type | Tab Wd. | Terminal Current, A | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: AG, SC, SLC | |||||||||
1 | G | 1-15 | 600V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 |
1 | G | 25-30 | 480V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 |
1 | G | 35-60 | 480V AC | Box-Lug Terminals | __ | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 | G | 20A | 600V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 |
2 | G | 1-15 | 600V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 |
2 | G | 25-30 | 480V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 |
2 | G | 35-60 | 480V AC | Box-Lug Terminals | __ | __ | UL Listed, CSA Certified | 0000000 | 000000 |
2 | G | 20A | 600V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 |
3 | G | 1-15 | 600V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 |
3 | G | 25-30 | 480V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 |
3 | G | 35-60 | 480V AC | Box-Lug Terminals | __ | __ | UL Listed, CSA Certified | 0000000 | 000000 |
3 | G | 20A | 600V AC | Box-Lug Terminals | __ | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 |
For Fuse Manufacturer Equivalent: ATQ-R, ATM-R, ATD-R, CCMR, FNQ-R, KLD-R, KLK-R, KTK-R, LP-CC | |||||||||
1 | CC | 1/10-30 | 600V AC | Quick-Disconnect Terminals | 0.25" | 20 | UL Listed, CSA Certified | 0000000 | 00000 |
2 | CC | 1/10-30 | 600V AC | Quick-Disconnect Terminals | 0.25" | 20 | UL Listed, CSA Certified | 0000000 | 00000 |
3 | CC | 1/10-30 | 600V AC | Quick-Disconnect Terminals | 0.25" | 20 | UL Listed, CSA Certified | 0000000 | 00000 |
DIN-Rail Mount Fuse Blocks for UL Class CC Midget Fuses
Covered terminals prevent contact with live electrical circuits.
For technical drawings and 3-D models, click on a part number.
For No. of Fuses | For Fuse Current, A | Voltage | Wire Connection Type | For DIN Rail Size, mm | Features | Ht. | Wd. | Dp. | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: ATD-R, ATM-R, ATQ-R, CCMR, FNQ-R, KLD-R, KLK-R, KTK-R, LP-CC | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals | 3.1" | 0.7" | 2.3" | UL Listed, CSA Certified | 0000000 | 000000 |
1 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | 3.1" | 0.7" | 2.3" | UL Listed, CSA Certified | 0000000 | 00000 |
2 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals | 3.1" | 1.4" | 2.3" | UL Listed, CSA Certified | 0000000 | 00000 |
2 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | 3.1" | 1.4" | 2.3" | UL Listed, CSA Certified | 0000000 | 00000 |
3 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals | 3.1" | 2.1" | 2.3" | UL Listed, CSA Certified | 0000000 | 00000 |
3 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | 3.1" | 2.1" | 2.3" | UL Listed, CSA Certified | 0000000 | 00000 |
4 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals | 3.1" | 2.8" | 2.3" | UL Listed, CSA Certified | 0000000 | 00000 |
4 | 1/10-30 | 600V DC/600V AC | Screw Terminals | 35 | Covered Terminals, Blown Fuse Indicator | 3.1" | 2.8" | 2.3" | UL Listed, CSA Certified | 0000000 | 000000 |
DIN-Rail Mount Fuse Blocks for Midget Fuses
Sized to fit non-UL Class Midget Fuses, these fuse blocks are suitable for switchboard panels, small motors, and transformers. The covered terminals prevent contact with live electrical circuits.
For technical drawings and 3-D models, click on a part number.
For No. of Fuses | For Fuse Current, A | Voltage | Wire Connection Type | For DIN Rail Size, mm | Features | Ht. | Wd. | Dp. | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: ATM, ATQ, BAF, BLF, FLM, FLQ, FNM, FNQ, KLK, KTK, OTM, TRM | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1/10-30 | 600V AC/600V DC | Screw Terminals | 35 | Covered Terminals | 3.1" | 0.7" | 2.3" | UL Recognized Component, CSA Certified | 0000000 | 000000 |
1 | 1/10-30 | 600V AC/600V DC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | 3.1" | 0.7" | 2.3" | UL Recognized Component, CSA Certified | 0000000 | 00000 |
2 | 1/10-30 | 600V AC/600V DC | Screw Terminals | 35 | Covered Terminals | 3.1" | 1.4" | 2.3" | UL Recognized Component, CSA Certified | 0000000 | 00000 |
2 | 1/10-30 | 600V AC/600V DC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | 3.1" | 1.4" | 2.3" | UL Recognized Component, CSA Certified | 0000000 | 00000 |
3 | 1/10-30 | 600V AC/600V DC | Screw Terminals | 35 | Covered Terminals | 3.1" | 2.1" | 2.3" | UL Recognized Component, CSA Certified | 0000000 | 00000 |
3 | 1/10-30 | 600V AC/600V DC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | 3.1" | 2.1" | 2.3" | UL Recognized Component, CSA Certified | 0000000 | 00000 |
DIN-Rail Mount Fuse Blocks for 1,000V DC Fast-Acting Fuses
Designed for the solar industry, these fuse blocks can handle the requirements of high-voltage DC applications. The covered terminals prevent contact with live electrical circuits.
For technical drawings and 3-D models, click on a part number.
For Fuse | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | Current, A | Overall Dia. | Overall Lg. | Voltage | Wire Connection Type | For DIN Rail Size, mm | Features | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: DCT, PV | ||||||||||
1 | 1-15 | 13/32" | 1 1/2" | 1,000V DC | Screw Terminals | 35 | Covered Terminals | EN 63000, IEC 63000, UL Recognized Component | 000000 | 000000 |
1 | 1-15 | 13/32" | 1 1/2" | 1,000V DC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | EN 63000, IEC 63000, UL Recognized Component | 000000 | 00000 |
Inline Fuse Holders for Midget Fuses
Designed for use with midget fuses, these fuse holders are compact to fit tight spaces. Crimp on for quick wire connection.
Cover (sold separately) provides a waterproof seal.
For Fuse | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Number of Fuses | UL Class | Current, A | Voltage | Lg. | Ht. | Material | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: ATD-R, ATM-R, ATQ-R, CCMR, FNQ-R, KLD-R, KLK-R, KTK-R, LP-CC | |||||||||
1 | CC | 1/10-30 | 600V AC | 4.3" | 1" | Plastic | UL Listed | 000000 | 000000 |
For Fuse Manufacturer Equivalent: ATM, ATQ, BAF, BLF, FLM, FLQ, FNM, FNQ, KLK, KTK, OTM, TRM | |||||||||
1 | __ | 1/10-30 | 600V AC | 4.3" | 1" | Plastic | UL Recognized Component | 000000 | 00000 |
Optional Rubber Covers (1" Dia., 3.4" Lg.) | 000000 | Each | 00000 |
Panel-Mount Fuse Holders for Midget Fuses
Sized to fit non-UL Class midget fuses, these compact fuse holders fit tight spaces. Insert fuses into holders and twist the cover closed.
Quick-Disconnect Tab | For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | For Fuse Current, A | Voltage | Wd. | Shape | Dia. | Dp. | Center-to-Center Mounting Hole Wd. | Lg. | Environment | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: FNM, TRM, FLM, FNQ, ATQ, FLQ, BAF, OTM, BLF, KTK, ATM, KLK | ||||||||||||
1 | 1/10-30 | 600V AC | 0.25" | Straight | 0.89" | 0.75" | 1.31" | 2.08" | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 |
1 | 1/10-30 | 600V AC | 0.25" | Straight | 0.89" | 0.75" | 1.31" | 2.08" | Washdown | UL Recognized Component, CSA Certified | 0000000 | 0000 |
1 | 1/10-30 | 600V AC | 0.25" | 90° Elbow | 0.89" | 0.75" | 1.31" | 2.08" | __ | UL Recognized Component, CSA Certified | 0000000 | 0000 |
1 | 1/10-30 | 600V AC | 0.25" | 90° Elbow | 0.89" | 0.75" | 1.31" | 2.08" | Washdown | UL Recognized Component, CSA Certified | 0000000 | 0000 |
Panel-Mount Fuse Holders for UL Class Midget Fuses
Designed for use with UL Class CC Midget fuses, these fuse holders are compact to fit tight spaces. Insert fuses into holders and twist the cover closed.
For Fuse | Quick-Disconnect Tab | For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | UL Class | Current, A | Voltage | Wd. | Shape | Dia. | Dp. | Center-to-Center Mounting Hole Wd. | Lg. | Environment | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: ATD-R, ATM-R, ATQ-R, CCMR, FNQ-R, KLD-R, KLK-R, KTK-R, LP-CC | |||||||||||||
1 | CC | 1/10-30 | 600V AC | 0.25" | Straight | 0.89" | 0.75" | 1.31" | 2.08" | __ | UL Recognized Component, CSA Certified | 0000000 | 000000 |
1 | CC | 1/10-30 | 600V AC | 0.25" | Straight | 0.89" | 0.75" | 1.31" | 2.08" | Washdown | UL Recognized Component, CSA Certified | 0000000 | 00000 |
1 | CC | 1/10-30 | 600V AC | 0.25" | 90° Elbow | 0.89" | 0.75" | 1.31" | 2.08" | __ | UL Recognized Component, CSA Certified | 0000000 | 00000 |
1 | CC | 1/10-30 | 600V AC | 0.25" | 90° Elbow | 0.89" | 0.75" | 1.31" | 2.08" | Washdown | UL Recognized Component, CSA Certified | 0000000 | 00000 |
Modular DIN-Rail Mount Terminal Blocks
Add as many circuits as you need with these terminal blocks and accessories. The terminal blocks clip onto DIN 3 rail and can be removed without disrupting adjacent blocks. Some also clip onto DIN 1 rail. All have screw-clamp terminals for a secure connection, reducing the chance of wire disconnecting due to vibrations, pulls, or snags. Rated UL 94 V-0, all meet flammability standards. Blocks that meet IP10 shield connections from objects larger than your hand; those that meet IP20 protect against objects larger than your fingers.
Grounding terminal blocks facilitate grounding circuits by electrically connecting wires to DIN rail. They shouldn’t be used for applications other than grounding.
Blocks with a fuse holder protect components and wire from short-circuit damage by enclosing the fuse.
Blocks with a blown fuse indicator light up so you’ll know if your fuse is blown without having to touch equipment or disconnect power.
Blocks with a disconnect tab or knob easily disconnect a circuit without needing to remove installed wire. Use them for testing. Disconnect knobs have a push-button with a through hole, so they can be sealed with wire when they’re disconnected, similar to a lockout tag. This reduces the risk of accidentally connecting the circuit. A test socket lets you try out your circuit. Insert a test plug (sold separately) into the socket, then use a voltage meter to check.
Blocks that are 51.5 mm or 63.5 mm high have a single circuit with multiple screw-clamp terminals, so they save space on DIN rail.
End covers fit on the open side of a block to prevent accidental contact with a live circuit.
End stops mount at the end of a group of blocks to keep them in place. Those rated IP20 provide additional protection from objects larger than your fingers.
Jumpers connect circuits between blocks to simplify wiring and leave terminals available to connect equipment. Blocks must be adjacent to each other and the same width. Bar jumpers screw down into designated sections on terminal blocks. You can cut them to size. Where listed, end covers should be used on the outermost blocks in the connection. Lateral jumpers are connected to blocks in place of a wire or in addition to a wire at the screw-clamp connection terminal points. Insulated jumpers eliminate the risk of your finger coming into contact with a live circuit, so they’re touch safe.
Marker cards fit into built-in label holders on the blocks.
For technical drawings and 3-D models, click on a part number.
Terminal Blocks (IP20 Rated) | End Covers | End Stops | Bar Jumpers | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | Each | Each | Each | ||||||||||||||
Wd., mm | Ht., mm | For Wire Gauge | Color | 1-24 | 25-Up | 1-24 | 25-Up | Environmental Rating | 1-24 | 25-Up | Insulation | 1-24 | 25-Up | ||||
800V AC/800V DC—32A Per Circuit | |||||||||||||||||
6 | 51.5 | 22-10 | Gray | 00000000 | 00000 | 00000 | 00000000 | 00000 | 00000 | IP20 | 0000000 | 00000 | 00000 | Insulated | 00000000 | 000000 | 00000 |
6 | 63.5 | 22-10 | Gray | 00000000 | 0000 | 0000 | 00000000 | 0000 | 000 | IP20 | 0000000 | 000 | 000 | Insulated | 00000000 | 00000 | 0000 |
Terminal Blocks (IP20 Rated) | End Covers | End Stops | Bar Jumpers | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | Each | Each | Each | ||||||||||||||
Wd., mm | Ht., mm | For Wire Gauge | Color | 1-24 | 25-Up | 1-24 | 25-Up | Environmental Rating | 1-24 | 25-Up | Insulation | 1-24 | 25-Up | ||||
630V AC/630V DC—24A Per Circuit | |||||||||||||||||
5 | 65.5 | 22-12 | Beige | 00000000 | 00000 | 00000 | 0000000 | 00000 | 00000 | IP20 | 00000000 | 00000 | 00000 | Insulated | 00000000 | 000000 | 000000 |
5 | 65.5 | 22-12 | Blue | 00000000 | 0000 | 0000 | 0000000 | 0000 | 0000 | IP20 | 00000000 | 0000 | 0000 | Insulated | 00000000 | 00000 | 00000 |
5 | 65.5 | 22-12 | Gray | 00000000 | 0000 | 0000 | 0000000 | 0000 | 0000 | IP20 | 00000000 | 0000 | 0000 | Insulated | 00000000 | 00000 | 00000 |
Each | ||||||
---|---|---|---|---|---|---|
Wd., mm | Ht., mm | For Wire Gauge | Color | 1-24 | 25-Up | |
500V AC/500V DC—32A Per Circuit | ||||||
6 | 87.5 | 22-12 | Black | 00000000 | 000000 | 000000 |
Terminal Blocks (IP20 Rated) | End Covers | End Stops | Bar Jumpers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Fuse | Each | Each | Each | Each | ||||||||||||||||
Wd., mm | Ht., mm | For Wire Gauge | O'all Dia., mm | O'all Lg., mm | Type | Color | 1-24 | 25-Up | 1-24 | 25-Up | Environmental Rating | 1-24 | 25-Up | Insulation | 1-24 | 25-Up | ||||
300V AC/300V DC—6.3A Per Circuit | ||||||||||||||||||||
8 | 99 | 20-12 | 5 | 20 | Ceramic, Glass | Gray | 00000000 | 000000 | 000000 | 00000000 | 00000 | 00000 | IP20 | 00000000 | 00000 | 00000 | Noninsulated | 0000000 | 000000 | 000000 |
630V AC/630V DC—6.3A Per Circuit | ||||||||||||||||||||
8 | 85.5 | 24-12 | 5 | 20 | Ceramic, Glass | Gray | 00000000 | 00000 | 00000 | 00000000 | 0000 | 0000 | IP20 | 00000000 | 0000 | 0000 | Insulated | 00000000 | 00000 | 00000 |
Fuse Holder and
Blown Fuse Indicator
Terminal Blocks (IP20 Rated) | End Covers | End Stops | Bar Jumpers | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Fuse | Each | Each | Each | Each | |||||||||||||||||
Wd., mm | Ht., mm | For Wire Gauge | Blown Fuse Indicator Voltage | O'all Dia., mm | O'all Lg., mm | Type | Color | 1-24 | 25-Up | 1-24 | 25-Up | Environmental Rating | 1-24 | 25-Up | Insulation | 1-24 | 25-Up | ||||
300V AC, 300V DC—6.3A Per Circuit | |||||||||||||||||||||
8 | 99 | 20-12 | 24V DC, 60V DC, 110V AC | 5 | 20 | Ceramic, Glass | Gray | 00000000 | 000000 | 000000 | 00000000 | 00000 | 00000 | IP20 | 00000000 | 00000 | 00000 | Noninsulated | 0000000 | 000000 | 000000 |
8 | 99 | 20-12 | 110V AC, 230V AC | 5 | 20 | Ceramic, Glass | Gray | 00000000 | 00000 | 00000 | 00000000 | 0000 | 0000 | IP20 | 00000000 | 0000 | 0000 | Noninsulated | 0000000 | 00000 | 00000 |
500V AC, 500V DC—6.3A Per Circuit | |||||||||||||||||||||
8 | 85.5 | 12 | 24V AC, 24V DC | 5 | 20 | Ceramic, Glass | Gray | 00000000 | 00000 | 00000 | 00000000 | 0000 | 0000 | IP20 | 00000000 | 0000 | 0000 | Insulated | 00000000 | 00000 | 00000 |
8 | 85.5 | 24-12 | 110V AC, 230V AC | 5 | 20 | Ceramic, Glass | Gray | 00000000 | 00000 | 00000 | 00000000 | 0000 | 0000 | IP20 | 00000000 | 0000 | 0000 | Insulated | 00000000 | 00000 | 00000 |
Disconnect
Tab
Terminal Blocks (IP20 Rated) | End Covers | End Stops | Lateral Jumpers | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | Each | Each | Each | ||||||||||||||
Wd., mm | Ht., mm | For Wire Gauge | Color | 1-24 | 25-Up | 1-24 | 25-Up | Environmental Rating | 1-24 | 25-Up | Insulation | 1-24 | 25-Up | ||||
320V AC/320V DC—10A Per Circuit | |||||||||||||||||
5 | 44.5 | 12 | Gray/Orange | 00000000 | 00000 | 00000 | 0000000 | 00000 | 00000 | IP20 | 0000000 | 00000 | 00000 | Noninsulated | 00000000 | 00000 | 00000 |
Test Socket and
Disconnect Knob
Terminal Blocks (IP10 Rated) | End Covers | End Stops | Test Plugs | Lateral Jumpers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | Each | Each | Each | Each | ||||||||||||||||
Wd., mm | Ht., mm | For Wire Gauge | Color | 1-24 | 25-Up | 1-24 | 25-Up | Environmental Rating | 1-24 | 25-Up | 1-24 | 25-Up | Insulation | 1-24 | 25-Up | |||||
500V AC/500V DC—15A Per Circuit | ||||||||||||||||||||
8 | 55.5 | 22-8 | Gray/Black | 00000000 | 00000 | 00000 | 00000000 | 00000 | 00000 | IP20 | 0000000 | 00000 | 00000 | 00000000 | 00000 | 00000 | Insulated | 00000000 | 00000 | 00000 |
8 | 55.5 | 22-8 | Gray/Red | 00000000 | 0000 | 0000 | 00000000 | 000 | 000 | IP20 | 0000000 | 000 | 000 | 00000000 | 0000 | 0000 | Insulated | 00000000 | 0000 | 0000 |
8 | 55.5 | 22-8 | Gray/Yellow | 00000000 | 0000 | 0000 | 00000000 | 000 | 000 | IP20 | 0000000 | 000 | 000 | 00000000 | 0000 | 0000 | Insulated | 00000000 | 0000 | 0000 |
For
Horizontal Rail
For Terminal Block Wd., mm | Number Range | Markers Per Card | 1-24 | 25-Up | |
Blank | |||||
---|---|---|---|---|---|
5 | __ | 100 | 00000000 | 00000 | 00000 |
6 | __ | 100 | 0000000 | 0000 | 0000 |
8, 10, 12, 13, 16, 22 | __ | 100 | 00000000 | 0000 | 0000 |
Numbered—For Horizontal Rail | |||||
8, 10, 12, 13, 16, 22 | 1-100 | 100 | 00000000 | 0000 | 0000 |
8, 10, 12, 13, 16, 22 | 101-200 | 100 | 00000000 | 0000 | 0000 |
Numbered—For Vertical Rail | |||||
8, 10, 12, 13, 16, 22 | 1-100 | 100 | 00000000 | 0000 | 0000 |
8, 10, 12, 13, 16, 22 | 101-200 | 100 | 00000000 | 0000 | 0000 |