About Paint and Protective Coatings
More
Engine Paint
This paint resists heat and automotive fluids for use on engines. Match the color to your manufacturers' equipment color.
Paint | Primer | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dry Time | Each | Each | |||||||||||||
Container Net Weight, oz. | Composition | Formulation | Touch, min. | O'all, hrs. | Approx. Coverage @ Thick. | For Use On | Primer Required For Use On | Choose a Color (Appearance) | 1-5 | 6-Up | Color | 1-5 | 6-Up | ||
12 | Solvent Based | Ceramic | 30 | 3 | 13 sq. ft. @ 1 mil | Steel, Iron, Masonry, Concrete, Wood | __ | 000000 | 000000 | 000000 | __ | 000000 | 00 | 00 | |
16 | Solvent Based | Alkyd | 10 | 48 | 18 sq. ft. @ 1 mil | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Iron, Galvanized Iron, Galvanized Steel, Titanium | Aluminum, Brass, Copper, Iron, Galvanized Iron, Galvanized Steel | Cummins Beige (Gloss) | 00000000 | 00000 | 00000 | Light Gray | 000000 | 000000 | 000000 |
Fork Truck Paint
Match the manufacturers' color of your forklift, lift truck, or pallet truck to cover scratches and wear.
Dry Time | Each | ||||||||
---|---|---|---|---|---|---|---|---|---|
Container Net Weight, oz. | Composition | Touch, min. | O'all, hrs. | Approx. Coverage @ Thick. | For Use On | Choose a Color (Appearance) | 1-5 | 6-Up | |
Alkyd | |||||||||
12 | Solvent Based | 15 | 24 | 15 sq. ft. @ 1 mil | Steel, Iron, Masonry, Concrete | 000000 | 000000 | 000000 |
Heavy Equipment Paint
Cover scratches and wear on heavy equipment, such as tractors, excavators, and bulldozers. Match the manufacturers' color to your equipment.
Paint | Primer | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dry Time | Each | Each | ||||||||||||
Container Net Weight, oz. | Composition | Touch, min. | O'all | Approx. Coverage @ Thick. | For Use On | Primer Required For Use On | Color (Appearance) | 1-5 | 6-Up | Color | 1-5 | 6-Up | ||
Alkyd | ||||||||||||||
12 | Solvent Based | 10 | 48 hrs. | 15 sq. ft. @ 1 mil | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Iron, Galvanized Iron, Galvanized Steel, Titanium | Aluminum, Brass, Copper, Iron, Galvanized Iron, Galvanized Steel | Case Power Tan (Gloss) | 0000000 | 000000 | 000000 | Light Gray | 000000 | 000000 | 000000 |
16 | Solvent Based | 10 | 48 hrs. | 18 sq. ft. @ 1 mil | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Iron, Galvanized Iron, Galvanized Steel, Titanium | Aluminum, Brass, Copper, Iron, Galvanized Iron, Galvanized Steel | Ryder Yellow (Gloss) | 0000000 | 00000 | 00000 | Light Gray | 000000 | 00000 | 00000 |
16 | Solvent Based | 10 | 48 hrs. | 18 sq. ft. @ 1 mil | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Iron, Galvanized Iron, Galvanized Steel, Titanium | Aluminum, Brass, Copper, Iron, Galvanized Iron, Galvanized Steel | Sunbelt Green (Gloss) | 0000000 | 00000 | 00000 | Light Gray | 000000 | 00000 | 00000 |
Enclosure Paint
Touch up scratches and wear on your enclosure with paint that matches its color. This acrylic lacquer paint has strong adhesion and resists detergent and water—including in washdown environments—as well as abrasion, heat, and alcohol. It sprays evenly onto surfaces, with no need for additional tools such as brushes.
Dry Time | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Net Weight, oz. | Composition | Touch, min. | Overall, days | Approximate Coverage @ Thickness | Spray Position | Maximum Temperature, °F | For Use On | Color (Appearance) | Color Code | Cannot Be Sold To | Each | |
Acrylic Lacquer | ||||||||||||
10 1/2 | Solvent Based | 8 | 7 | 28 sq. ft. @ 1 mil | Upright | 100° | Steel, Stainless Steel | Black (Gloss) | __ | CA | 00000000 | 000000 |
10 1/2 | Solvent Based | 8 | 7 | 28 sq. ft. @ 1 mil | Upright | 100° | Steel, Stainless Steel | Black (Semi-Gloss) | __ | CA | 00000000 | 00000 |
10 1/2 | Solvent Based | 8 | 7 | 28 sq. ft. @ 1 mil | Upright | 100° | Steel, Stainless Steel | Gray (Gloss) | ANSI 61 | CA | 00000000 | 00000 |
10 1/2 | Solvent Based | 8 | 7 | 28 sq. ft. @ 1 mil | Upright | 100° | Steel, Stainless Steel | Light Gray (Gloss) | RAL 7035 | CA | 00000000 | 00000 |
10 1/2 | Solvent Based | 8 | 7 | 28 sq. ft. @ 1 mil | Upright | 100° | Steel, Stainless Steel | White (Gloss) | RAL 9003 | CA | 00000000 | 00000 |
Lifting Equipment Paint
Match the manufacturers’ color of your lift, jack, or motor to cover scratches and wear. This paint resists oil, gas, heat, and sunlight for use in demanding environments.
Paint | Primer | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dry Time | Each | Each | |||||||||||||
Container Net Weight, oz. | Composition | Formulation | Touch, min. | O'all, hrs. | Approx. Coverage @ Thick. | For Use On | Primer Required For Use On | Choose a Color (Appearance) | 1-5 | 6-Up | Color | 1-5 | 6-Up | ||
16 | Solvent Based | Alkyd | 10 | 48 | 18 sq. ft. @ 1 mil | Aluminum, Steel, Stainless Steel, Iron, Galvanized Iron, Galvanized Steel | Aluminum, Iron, Galvanized Iron, Galvanized Steel | 000000 | 000000 | 000000 | Light Gray | 000000 | 000000 | 000000 |
Paint for Metal
Paint metal surfaces to stop rust from starting and prevent existing rust from spreading. Scrape rusty areas clean before application. Although primer is not required for use on all materials, it can be used to prepare any surface to maximize the life and corrosion resistance of paint.
Silicone paint stops corrosion on high-temperature surfaces, such as smokestacks, incinerators, heaters, and heat exchangers. To apply paint with a 2-hour overall dry time, spray paint on, and then increase the temperature two to three times (450° to 650° F), allowing surface to cool between firings.
Paint in an aerosol can does not require a primer.
Container | Dry Time | Each | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Net Weight, oz. | Composition | Touch | O'all | Approx. Coverage @ Thick. | Max. Temp., °F | For Use On | Choose a Color (Appearance) | 1-5 | 6-Up | |
Silicone—Aerosol Can | ||||||||||
11 | Solvent Based | 30 min. | 2 hrs. | 20 sq. ft. @ 1 mil | 1200° | Steel, Stainless Steel | 000000 | 000000 | 000000 |
Line Marking Paint
Mark traffic lanes, parking lots, and factory floors.
Alkyd paint dries quickly and can also be used on turf.
Container | Dry Time | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Net Weight, oz. | Composition | Formulation | Touch, min. | O'all | Approx. Coverage @ Stripe Wd. | Max. Temp., °F | Application Temp. Range, °F | For Use Outdoors | For Use On | Choose a Color (Appearance) | Each | |
Aerosol Can | ||||||||||||
17 | Solvent Based | Alkyd | 15 | 60 min. | 550 ft. @ 2" | 250° | 50° to 80° | Yes | Steel, Stainless Steel, Iron, Concrete, Asphalt, Wood, Turf | 000000 | 00000 |
Paint for Ceiling Tiles
Restore existing water- and smoke-stained ceiling tiles to their original appearance.
New white provides a bright, new-tile look.
Dry Time | Each | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Net Weight, oz. | Composition | Formulation | Touch, min. | O'all, hrs. | Approx. Coverage @ Thick. | Max. Temp., °F | For Use Outdoors | For Use On | Color (Appearance) | 1-11 | 12-Up | |
16 | Water Based | Acrylic | 15 | 6 | 15 sq. ft. @ 1 mil | 250° | No | Drywall, Ceiling Tile | New White (Flat) | 0000000 | 000000 | 000000 |
Heat-Radiating Coatings
Able to withstand temperatures of up to 2000° F, these coatings absorb heat and release it later. Use them to improve the thermal efficiency of heaters, furnaces, and ovens to reduce energy costs. Also known as high-emissivity coatings, they have an emissivity rating of 0.9—the closer a material’s rating is to 1.0, the more heat it will absorb and later radiate. Apply with a brush or sprayer.
Dry Time | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Container Size, qt. | Composition | Touch, min. | O'all, hrs. | Approximate Coverage @ Thickness | Max. Temp., °F | Application Temp. Range, °F | For Use On | Color (Appearance) | Each | |
Ceramic | ||||||||||
1 | Water Based | 20 | 3 | 125 sq. ft. @ 2 mil | 2000° | 55° to 85° | Ceramic, Concrete | Black (Flat) | 000000 | 0000000 |
Protective Coatings
Used to insulate, create grips, and color-code components, these coatings resist high temperatures, light abrasion, and corrosion.
Rubber coatings withstand salt and acids. Although primer is not required for use on all materials, it can be used to prepare any surface to maximize the life of the coating. Apply topcoat to give coated surfaces a glossy finish that resists fading.
PVC plastic coatings can be used on nearly any surface, including rubber. They withstand salt, acids, alkalies, and gasoline. They also resist UV light, so they won’t lose their color when exposed to sunlight over long periods of time.
Coatings that cannot be sold outside of the United States do not meet product labeling requirements.
Primers and topcoats cannot be sold outside of the United States due to product regulations.
VOC (Volatile Organic Compounds) regulations restrict sales to the listed jurisdictions/areas.
Protective Coatings | Topcoats | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Container | Dry Time | Each | Primers | Each | ||||||||||||
Net Weight | Composition | Touch, min. | O'all | Approximate Coverage @ Thickness | For Use On | Primer Required For Use On | Choose a Color (Appearance) | Cannot Be Sold To | 1-5 | 6-Up | Each | 1-5 | 6-Up | |||
Rubber—Aerosol Can | ||||||||||||||||
11 oz. | Solvent Based | 40 | 24 hrs. | 6 sq. ft. @ 5 mil | Steel, Iron, Plastic, Wood, Fabric | Steel, Iron | Outside United States | 000000 | 000000 | 000000 | 0000000 | 000000 | 000000 | 000000 | 000000 |
Powder Coatings
More durable and scratch resistant than liquid paint, use this dry paint with your powder coating system. Apply directly to unpainted metal and heat-cure in an oven for a smooth, baked-on finish.
Dry Time | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Color (Appearance) | Color Code | Container Net Weight, oz. | Composition | Touch, min. | Overall, min. | Approx. Coverage @ Thick. | Max. Temp., °F | Application Temp. Range, °F | For Use On | Each | |
Black (Gloss) | __ | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 000000 |
Black (Semi-Gloss) | __ | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Black (Matte) | __ | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Clear (Gloss) | __ | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Dark Blue (Gloss) | RAL 5005 | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Dark Green (Gloss) | RAL 6028 | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Light Gray (Gloss) | RAL 7035 | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Orange (Gloss) | RAL 2011 | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Red (Gloss) | RAL 3020 | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
White (Gloss) | RAL 9010 | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Yellow (Gloss) | RAL 1023 | 16 | Solvent Based | 10 | 10 | 68 sq. ft. @ 2 mil | 350° | 50° to 80° | Aluminum, Brass, Bronze, Copper, Steel, Titanium, Iron | 00000000 | 00000 |
Reflective Powder Coatings
Make guardrails, poles, and other safety equipment stand out in low-light environments. The glass beads in these coatings reflect the light. They’re more durable and scratch resistant than liquid paint. Apply directly to unpainted metal and cure in an oven for a smooth, baked-on finish.
Dry Time | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Color (Appearance) | Container Net Weight, lbs. | Composition | Touch, min. | Overall, min. | Approx. Coverage @ Thick. | Max. Temp., °F | Application Temp. Range, °F | For Use On | Each | |
Black (Gloss) | 5 | Solvent Based | 10 | 10 | 105 sq. ft. @ 1 mil | 400° | 45° to 75° | Aluminum, Steel, Iron | 0000000 | 0000000 |
Flexible Rubber Coatings for Metal
These flexible, slip-resistant silicone coatings resist chemicals, block UV light, and encapsulate lead paint. They withstand temperatures up to 320° F. Apply with a brush, roller, or sprayer.
Dry Time | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Touch | O'all, hrs. | Approximate Coverage @ Thickness | Max. Temp., °F | Application Temp. Range, °F | For Use On | Choose a Color (Appearance) | Each | |
Silicone | ||||||||||
1 | Solvent Based | 60 | 24 | 100 sq. ft. @ 10 mil | 320° | 40° to 80° | Steel, Iron, Composites, Wood | 000000 | 0000000 |
Clean-Away Coatings for Metal
Protect metal parts from corrosion. Also known as rust-inhibiting film, these coatings can be removed with a simple degreaser or mineral spirits.
Mineral oil coatings don’t fully dry, so they leave a tacky film. Coating with a maximum temperature of 250° F lubricates as it protects and can be used as a start-up lubricant for stored machinery.
Coatings that cannot be sold to the regions listed are restricted by product labeling requirements or exceed local regulatory limits on VOCs (volatile organic compounds).
Container | Max. Protection Time | Each | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. | Mfr. Model No. | Net Weight, oz. | Indoor, mo. | Approx. Coverage @ Thick. | Max. Temp., °F | Application Temp. Range, °F | For Use On | Color | Cannot Be Sold To | 1-11 | 12-Up | |
Solvent Based Mineral Oil Coatings | ||||||||||||
CRC | CRC SP-350 | 11 | 24 | 50 sq. ft. @ 1 mil | 250° | 40° to 90° | Steel, Iron | Transparent Yellow | Outside United States | 00000000 | 000000 | 000000 |
Wear-Resistant Coatings for Metal
Also known as brushable ceramic, these coatings create a hard, low-friction surface that resists corrosion. They're often used on liquid processing equipment, such as pump casings, impeller blades, and valves, to protect worn areas and reduce turbulence. They’re also used on heat exchangers, condensers, and chutes. The size listed is the combined total of the two parts.
Devcon Brushable Ceramic resists acids, alkalies, fuels, and solvents. Apply with a brush or roller.
Container | Dry Time | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Net Weight, lbs. | Composition | Touch, min. | Overall, hrs. | Approx. Coverage @ Thick. | Application Time After Mixing, min. | Max. Temp., °F | Application Temp. Range, °F | For Use On | Color (Appearance) | Each | |
Devcon Brushable Ceramic Coatings | ||||||||||||
11765 | 2 | Solvent Based | 40 | 16 | 15 sq. ft. @ 20 mil | 40 | 350° | 55° to 90° | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Cast Iron, Titanium | Blue (Gloss) | 00000000 | 0000000 |
Flame-Retardant Coatings for Metal
Use these coatings on structural steel beams and pipes. Apply with a brush, roller, or sprayer. The size listed is the combined total of the two parts.
Dry Time | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Touch, hrs. | Overall, hrs. | Approx. Coverage @ Thick. | Application Time After Mixing, hrs. | Max. Temp., °F | Application Temp. Range, °F | Flammability Rating | For Use On | Color (Appearance) | Each | |
1 | Water Based | 8 | 48 | 110 sq. ft. @ 15 mil | 2.5 | 300° | 40° to 100° | UL 94 V-0 | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Titanium, Iron, Galvanized Iron, Galvanized Steel, Silver | White (Flat) | 000000 | 0000000 |
Reflective Acrylic Coatings for Roofs
Reflect at least 85% of the sun's rays to reduce cooling costs. These coatings also restore and reinforce your roof by filling cracks and forming a water-resistant seal. Apply to a dry surface with a brush, roller, or sprayer.
Primer (sold separately) extends the life of the coating. It’s required for use on bare rubberized and aged asphalt roofs.
Dry Time | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Container Size, gal. | Composition | Surface Reflectivity | Touch, hrs. | Overall | Approx. Coverage, sq. ft. | Max. Temp., °F | Application Temp. Range, °F | For Use On | Color | Each | |
1 | Water Based | 85% | 2 | 24 hrs. | 100 | 375° | 60° to 200° | Aluminum, Galvanized Steel, Galvanized Iron, Masonry, Concrete, Wood, Composites | White | 000000 | 000000 |
Weld-Through Primers for Metal
Protect steel and iron parts from corrosion without having to remove the primer before welding them together. Often used on structural steel in demanding environments, these primers can be welded through without affecting the weld’s integrity.
Product labeling requirements restrict sales to the listed areas.
Container | Dry Time | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Net Weight, oz. | Composition | Touch, min. | Overall, hrs. | Max. Temp., °F | For Topcoat Composition | For Use On | Color | Cannot Be Sold To | Each | |
Aerosol Can | ||||||||||
12 1/2 | Solvent Based | 15 | 24 | 250° | Solvent Based, Water Based | Aluminum, Steel, Iron | Gray | Outside United States | 0000000 | 000000 |
Powder Coating Primers
Prepare metal surfaces for powder coating. These primers create a base layer that bonds with your top coat to extend the life of your powder coating. Use a powder coating sprayer to apply these primers directly to unpainted metal and cure in an oven.
Epoxy primers are good general purpose primers for most metal.
Zinc/epoxy primers have excellent corrosion resistance, so they’re often used to protect metal that rusts easily, such as steel and cast iron.
Container | Dry Time | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Net Weight, oz. | Type | Composition | Touch, min. | Overall, min. | Approx. Coverage @ Thick. | Max. Temp., °F | Application Temp. Range, °F | For Topcoat Composition | For Use On | Color | Each | |
Epoxy | ||||||||||||
16 | Bag | Solvent Based | 20 | 20 | 60 sq. ft. @ 2 mil | 400° | 40° to 75° | Solvent Based | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Titanium, Wood, Iron, Nickel | Gray | 00000000 | 000000 |
Zinc/Epoxy | ||||||||||||
16 | Bag | Solvent Based | 20 | 20 | 43 sq. ft. @ 2 mil | 400° | 40° to 75° | Solvent Based | Brass, Bronze, Copper, Steel, Stainless Steel, Titanium, Wood, Iron, Nickel | Black | 00000000 | 00000 |
High-Temperature Surface Fillers for Metal
Repair and rebuild metal surfaces that are exposed to heat. These surface fillers withstand temperatures over 450° F. Fillers that have a mix ratio are multi-part fillers. The size listed is the combined total of the parts.
Surface fillers in a stick have a resin on the outside and a hardener on the inside. Cut the desired amount from the sticks, knead to a uniform color to mix, and press into place.
Surface fillers in a syringe come with everything you need to make repairs.
Container | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Size, fl. oz. | Net Weight, oz. | Type | Begins to Harden | Reaches Full Strength, hrs. | Heating Requirements to Reach Full Strength | Consistency | Mix Ratio | Approx. Coverage @ Thick. | Temp. Range, °F | Color | Finishing Method | For Use On | Each | |
Loctite® Fixmaster 2000° Putty | |||||||||||||||
MR 2000 | 8 | __ | Can | 30 min. | 7 | __ | Putty | __ | 30 sq. in. @ 1/4" | Not Rated to 2000° | Gray | Machine, Drill, Sand, Saw, Tap | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Cast Iron, Titanium | 0000000 | 0000000 |
Surface Fillers | |||||||||||||||
__ | __ | 4 | Stick | 90 min. | 72 | __ | Putty | __ | 16 sq. in. @ 1/4" | -40° to 450° | Gold | Drill, Sand, Tap | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Cast Iron, Titanium | 0000000 | 00000 |
__ | 1.5 | __ | Syringe | 20 min. | 24 | __ | Putty | 9.1:1 | 1 sq. in. @ 1/4" | -40° to 500° | Gray | Machine, Drill, Saw | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Cast Iron, Titanium, Fiberglass | 0000000 | 00000 |
__ | 8 | __ | Can | 5 hrs. | 6 | 2 hrs. air dry then 4 hrs. @ 200° F | Putty | __ | 32 sq. in. @ 1/4" | Not Rated to 2000° | Dark Gray | Sand | Steel, Stainless Steel, Cast Iron | 0000000 | 00000 |
__ | 12 | __ | Can, Bottle | 2 hrs. | 6 | 4 hrs. air dry then 2 hrs. @ 160° F | Putty | 2:1 | 48 sq. in. @ 1/4" | Not Rated to 1400° | Light Gray | Sand | Aluminum | 0000000 | 00000 |
__ | 16 | __ | Can, Bottle | 20 min. | 24 | __ | Putty | 9.1:1 | 10 sq. in. @ 1/4" | Not Rated to 500° | Gray | Machine, Drill, Saw | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Cast Iron, Titanium, Fiberglass | 0000000 | 00000 |
__ | 16 | __ | Bottle | 5 hrs. | 6 | 2 hrs. air dry then 4 hrs. @ 200° F | Putty | __ | 65 sq. in. @ 1/4" | Not Rated to 2000° | Dark Gray | Sand | Steel, Stainless Steel, Cast Iron | 0000000 | 000000 |
__ | 24 | __ | Can | 2 hrs. | 6 | 4 hrs. air dry then 2 hrs. @ 160° F | Putty | 2:1 | 96 sq. in. @ 1/4" | Not Rated to 1400° | Light Gray | Sand | Aluminum | 0000000 | 000000 |
High-Pressure Leak-Repair Sticks for Metal
To stop leaks in metal tanks and equipment without draining the contents, heat the area with a heat gun or torch to melt the stick and form a permanent seal. The resulting patch can withstand pressure up to 600 psi. These sticks meet NSF/ANSI 61 safety standards for use with drinking water systems.
Container Net Weight, oz. | Begins to Harden, min. | Reaches Full Strength, sec. | Temp. to Begin to Harden, °F | Consistency | Max. Thick. | For Use Outdoors | Temp. Range, °F | Color | Specifications Met | Finishing Method | For Use On | Each | |
0.375 | 1 | 90 | 250 | Putty | 1/8" | Yes | Not Rated to 350° | Green | NSF/ANSI 61 | Sand | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Cast Iron, Titanium | 000000 | 000000 |
Conductive Surface Filler Pens for Electronics
Dispense ready-to-use conductive liquid to fill pits and small gaps on circuit board components. These pens are also used to sketch and repair conductive pathways.
Product labeling requirements restrict sales to the listed areas.
Silver epoxy pens are the most versatile—use them for any type of repair as well as for repairs that require excellent conductivity, such as connecting through holes on circuit boards without adding jumpers, wiring, or solder. Since they have the lowest surface resistivity, they allow the most current to pass.
Tip | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Container Size, fl. oz. | Dia. | Shape | Begins to Harden, min. | Reaches Full Strength | Surface Resistivity, ohms/sq. | Consistency | Max. Thick. | For Use Outdoors | Temp. Range, °F | Color | For Use On | Cannot Be Sold To | Each | |
Silver Epoxy | ||||||||||||||
0.2 | 0.03" | Point | 3 | 60 min. | 0.050 | Thin Liquid | Not Rated | No | -65° to 300° | Silver | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Titanium | Outside United States and Canada | 0000000 | 000000 |
Conductive Surface Fillers for Electronics
A high silver content allows these surface fillers to conduct electricity and heat. Use them to fill gaps and rebuild missing material on electrical connections or to assemble new components. They come as two parts. The size listed is the combined total of the two parts.
Volume resistivity measures how well a material opposes the flow of electricity. The lower the rating, the more electricity it conducts.
Thermal conductivity measures a material’s ability to transfer heat. The higher the rating, the more heat it transfers.
Container | Temp. Range, °F | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Size, fl. oz. | Net Weight, oz. | Type | Begins to Harden | Reaches Full Strength | Thermal Conductivity, W/m-K | Volume Resistivity, ohms-cm | Mix Ratio | Min. | Max. | For Use On | Each | |
Surface Fillers | ||||||||||||
__ | 0.09 | One-Time-Use Packet | 90 min. | 24 hrs. | 6.05 | 0.009 | 100:6 | -75° | 250° | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Titanium, Ceramic, Glass | 0000000 | 000000 |
__ | 0.35 | One-Time-Use Packet | 90 min. | 24 hrs. | 6.05 | 0.009 | 100:6 | -75° | 250° | Aluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Titanium, Ceramic, Glass | 0000000 | 000000 |
0.5 | __ | Jar | 4 hrs. | 5 days | 5.77 | 0.0004 | 1:1 | Not Rated | 300° | Aluminum, Brass, Copper, Steel, Stainless Steel | 0000000 | 000000 |
1 | __ | Jar | 4 hrs. | 5 days | 5.77 | 0.0004 | 1:1 | Not Rated | 300° | Aluminum, Brass, Copper, Steel, Stainless Steel | 0000000 | 000000 |
High-Temperature Surface Fillers
Able to withstand temperatures up to 2300° F, these ceramic surface fillers are often used as thermal insulation on brick, mortar, burner blocks, furnace holders, and thermocouples.
Container | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Size | Type | Begins to Harden, min. | Reaches Full Strength, hrs. | Consistency | Approximate Coverage @ Thick. | For Use Outdoors | Color | For Use On | Each | |
4 fl. oz. | Syringe | 20 | 8 | Putty | 20 sq. in. @ 1/4" | No | White | Ceramic, Masonry | 0000000 | 000000 |
11 fl. oz. | Cartridge | 20 | 8 | Putty | 60 sq. in. @ 1/4" | No | White | Ceramic, Masonry | 0000000 | 00000 |