Flame-Resistant Disposable Coveralls
Made of self-extinguishing Pyrolon, these coveralls help comply with NFPA 2113 standards when worn over flame-resistant clothing. Pyrolon won’t melt or drip if intermittently exposed to flames, which reduces the risk of burns. These coveralls provide full body coverage and are breathable to keep you cool while working. They have a zipper down the front.
Open cuffs provide better airflow than elastic cuffs. Elastic cuffs help keep dirt and grime out better than open cuffs.
Use the size chart for general guidance. When choosing a size, consider individual body shape and clothing worn underneath.
Available Sizes | ||
---|---|---|
Size | For Height | For Weight |
L | 5'5"-5'10" | 140-200 lbs. |
XL | 5'7"-6'2" | 150-220 lbs. |
2XL | 5'11"-6'4" | 180-240 lbs. |
3XL | 6'2"-6'5" | 230-280 lbs. |
4XL | 6'4"-6'8" | 240-300 lbs. |
Material | Closure Type | Cuff Style | Specifications Met | Color | Choose a Size | Each | |
Long Sleeve | |||||||
---|---|---|---|---|---|---|---|
Pyrolon Fabric | Zipper | Open | NFPA 2113 | Light Blue | 0000000 | 00000 | |
Pyrolon Fabric | Zipper | Elastic | NFPA 2113 | Light Blue | 0000000 | 00000 | |
Hooded Long Sleeve | |||||||
Pyrolon Fabric | Zipper | Elastic | NFPA 2113 | Light Blue | 0000000 | 00000 | |
Hooded Long Sleeve with Boot Covers | |||||||
Pyrolon Fabric | Zipper | Elastic | NFPA 2113 | Light Blue | 0000000 | 00000 |
Flame- and Arc-Flash-Protection Rain Suits
These suits meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These suits are made of PVC-coated Nomex aramid. Jackets have snaps down the front and a storm flap to keep rain out. Sleeves have hook and loop cuffs; tighten to fit your wrist or expand to wear over gloves. The bib overalls have adjustable suspenders to modify the length.
When measuring chest size, measure around the fullest part of your chest. Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these suits.
Available Sizes | |||
---|---|---|---|
Size | Chest Size | Waist Size | Inseam Lg. |
S | 46" | 42" | 28" |
M | 50" | 46" | 29" |
L | 54" | 50" | 30" |
XL | 58" | 54" | 31" |
2XL | 62" | 58" | 32" |
3XL | 66" | 62" | 32" |
Flame- and Arc-Flash-Protection Coveralls
These coveralls meet NFPA 70E standards for protection against electrical arc flashes. Check the personal protection equipment (PPE) category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance.
NFPA 2112 rated coveralls protect against flash fires.
Nomex aramid (men's) won’t melt or drip if it catches fire. It resists wear and abrasion better than other materials. It’s arc rated for PPE category 1.
Cotton (men's) is lightweight and provides better breathability than other materials. Coveralls are stitched with Nomex threads for added durability. They are self-extinguishing and arc rated for PPE category 2.
Cotton/nylon blend (men's) is soft, yet wear resistant, and provides better breathability than modacrylic/aramid blend and Nomex aramid. It’s arc rated for PPE category 2.
Acrylic/Buna-N (men's) is breathable and moisture wicking to keep you cool and dry. It’s arc rated for PPE category 2.
Carbon fiber (women’s), similar to acrylic/Buna-N, is lightweight, breathable, and moisture wicking to keep you cool and dry. It’s arc rated for PPE category 2.
Modacrylic/aramid blend (men's) provides better resistance against arc flashes and is more durable than cotton and acrylic/Buna-N. It’s arc rated for PPE category 4.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls. Long coveralls have added length in the torso, sleeves, and legs, so they are recommended for workers 6' 1" and taller.
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 36" |
S | 38" |
M | 40" |
M | 42" |
L | 44" |
L | 46" |
XL | 48" |
XL | 50" |
2XL | 52" |
2XL | 54" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 38" |
M | 40" |
M | 42" |
L | 44" |
L | 46" |
XL | 48" |
XL | 50" |
2XL | 52" |
2XL | 54" |
3XL | 56" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 36" |
M | 38" |
L | 42" |
XL | 44" |
2XL | 48" |
3XL | 52" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
M | 40"/42" |
L | 44"/46" |
XL | 48"/50" |
2XL | 52"/54" |
3XL | 56"/58" |
4XL | 60"/62" |
Available Womens's Sizes | |
---|---|
Size | Chest Size |
S | 34" |
M | 37" |
L | 40" |
XL | 43" |
2XL | 47" |
3XL | 50" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 36" |
M | 38" |
L | 42" |
XL | 44" |
2XL | 48" |
3XL | 52" |
Flame- and Arc-Flash-Protection Bib Overalls
These overalls meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 4. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. Made of modacrylic/aramid blend, these overalls are extremely durable. They have adjustable suspenders; tighten or loosen them to modify the fit. Adjust the hook and loop straps on the cuffs to tighten pant legs around boots.
Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these overalls.
Welding Coveralls
Made of cotton, these coveralls are treated to protect against low radiant heat and minor sparks when welding. They have five pockets and a flap down the front that conceals the snaps.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
Arc-Flash-Protection Equipment Kits
For protection from low-level arc flash hazards, these kits include several of the necessary safety items in a storage bag. All contents meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. All hard hats have a ratchet adjustment with an easy-turn knob.
Style B kits come with coveralls, hard hat, face shield, hood, and two storage bags.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
Hard Hat | Face Shield | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Arc Rating, cal/cm2 | Arc Rated PPE Category | No. of Suspension Points | Material | Hat Size | Lens Material | Lens Ht. | Lens Wd. | Lens Thick. | Material | Choose a Size (Chest Size) | Each | |
8 | 2 | 4 | Polyethylene Plastic | 6 1/2-8 | Polycarbonate Plastic | 12" | 8" | 0.09" | Cotton/Nylon Fabric Blend | 000000 | 0000000 | |