About Pressure Transmitters
More
Differential Pressure Transmitters for Air
- For Use With: Air
- Accuracy: ±0.8%
- Tube Connection: Barbed
- Housing Material: ABS Plastic
- Connection Material: Brass
- Temperature Range: 0° to 160° F
Remotely monitor the difference in air pressure between two inputs with these transmitters. Also known as transducers, they convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. These transmitters are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. They mount directly to DIN rail or a flat surface without the need for additional brackets. CE marked, all meet European safety standards. These transmitters are rated NEMA 1 for indoor use.
When measuring pressure in ductwork, pair them with a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range , in. of H2O | Max. Input Pressure, in. of H2O | Input Voltage | For Tube ID | For DIN Rail Ht., mm | Mounting Hardware Included | Top Dia. (No. of) | Bottom Dia. (No. of) | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Output Signal—Screw Terminals | ||||||||||||
DIN Rail or Surface Mount | ||||||||||||
-15 to 15 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 0000000 |
-10 to 10 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-5 to 5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-2.5 to 2.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-1 to 1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-0.5 to 0.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-0.25 to 0.25 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-0.1 to 0.1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 0.1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 0.25 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 0.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 2.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 10 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 25 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 50 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 100 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
High-Accuracy Differential Pressure Transmitters
- For Use With: Air, Water
- Accuracy: ±0.25%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: 17-4 PH Stainless Steel
- Temperature Range: 0° to 175° F
At least twice as accurate as standard transmitters, these transmitters sense differential pressure at an accuracy of ±0.25%. Use them in laboratories or testing applications where the difference in pressure between two points needs to be measured with high accuracy. These transmitters are often used to indicate a filter is clogged or help you maintain a certain pressure in pumps, HVAC, cooling, and other air and liquid systems. They convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. All transmitters are rated NEMA 4 for protection in washdown environments.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. As the differential increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-1 | 350 | 9-30V DC | 1/4 | Yes | 5/32" | 4 | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 000000000 |
0-2 | 350 | 9-30V DC | 1/4 | Yes | 5/32" | 4 | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 00000000 |
0-5 | 350 | 9-30V DC | 1/4 | Yes | 5/32" | 4 | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 00000000 |
0-10 | 350 | 9-30V DC | 1/4 | Yes | 5/32" | 4 | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 00000000 |
0-25 | 350 | 9-30V DC | 1/4 | Yes | 5/32" | 4 | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 00000000 |
0-50 | 350 | 9-30V DC | 1/4 | Yes | 5/32" | 4 | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 00000000 |
Differential Pressure Transmitters with Digital Display for Air
With a digital display and selectable differential pressure ranges, these transmitters are a versatile alternative to transmitters with dial indicators. Unlike a standard transmitter that has one wider differential pressure range, these transmitters have multiple ranges to choose from. The selectable pressure range means they are more accurate than standard transmitters since their accuracy applies to each small range rather than a single wide range. They can also be configured to output either current or voltage, while standard transmitters typically output one signal type. The digital display allows you to troubleshoot and monitor differential pressure at the source. Also known as transducers, they measure the difference in pressure between two inputs and convert it to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are rated UL 94 V-0, so they meet flammability standards. CE marked, they also meet European safety standards.
When measuring pressure in ductwork, pair them with a static pressure probe. Transmitters with an 8" pressure probe cable include a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Connect them using two wires when using the current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. For voltage output, connect them using three wires—two wires into the power supply and a separate wire to send a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
DIN-rail/surface mount transmitters give you mounting flexibility. They include the bracket you'll need for mounting it to DIN rail.
Transmitters with a calibration certificate traceable to NIST have passed tests for accuracy.
IP66 rated transmitters protect against dust and washdowns. Transmitters that meet IP67 protect against dust and submersion. NEMA 4X rated transmitters protect against dirt, weather, corrosion, and washdowns.
- For Use With: Air
- Accuracy: ±1%
- Tube Connection Type: Barbed
- Connection Material: Nylon Plastic
- Temperature Range: -4° to 158° F
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, in. of H2O | Max. Input Pressure, in. of H2O | Input Voltage | For Tube ID | Mounting Hardware Included | Dia. | No. of | Ht. | Dp. | Environmental Rating | Each | |
4-20 mA, 0-5V DC, 0-10V DC Output Signal—Screw Terminals | |||||||||||
Surface Mount | |||||||||||
0 to 0.1 0 to 0.15 0 to 0.25 0 to 0.5 | 99 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 0000000 |
0 to 1 0 to 2 0 to 3 0 to 5 | 166 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 000000 |
0 to 10 0 to 15 0 to 25 0 to 28 | 166 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 000000 |
- For Use With: Air
- Accuracy: ±1%
- Tube Connection Type: Barbed
- Connection Material: Brass
- Temperature Range: 32° to 122° F
Mounting Holes | Transmitters with Calibration Certificate Traceable to NIST | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, in. of H2O | Max. Input Pressure, psi | Input Voltage | For Tube ID | For DIN Rail Ht., mm | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Pressure Probe Cable Length | Environmental Rating | Each | |
4-20 mA, 0-5V DC, 0-10V DC Output Signal—Screw Terminals | |||||||||||||
Surface Mount | |||||||||||||
-5 to 5 -2.5 to 2.5 -1 to 1 -0.5 to 0.5 0 to 0.5 0 to 1 0 to 2.5 0 to 5 | 10 | 13-30V DC | 3/16" | __ | No | 3/16" | 2 | 5 7/16" | 3 3/16" | __ | IP67 | 0000000 | 0000000 |
DIN-Rail/Surface Mount | |||||||||||||
-5 to 5 -2.5 to 2.5 -1 to 1 -0.5 to 0.5 0 to 0.5 0 to 1 0 to 2.5 0 to 5 | 10 | 13-30V DC | 3/16" | 35 | No | 3/16" | 2 | 5 7/16" | 3 3/16" | 8" | IP67 | 0000000 | 000000 |
Differential Pressure Transmitters for Liquids
Used with pumps, cooling systems, and other liquid applications, these transmitters remotely measure the difference in pressure between two inputs. They are also known as transducers. These transmitters convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. You’ll often see them used to indicate a filter is clogged.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
IP56 rated transmitters protect against some dust and washdowns. IP66 rated transmitters are dust tight and protect against washdowns. NEMA 4 rated transmitters protect against weather and washdowns. NEMA 4X rated transmitters protect against weather, washdowns, and corrosion.
- For Use With: Hydraulic Fluid, Water
- Accuracy: ±1%
- Pipe Connection: NPT Female
- Connection Material: Brass
- Temperature Range: 32° to 122° F
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-1 in. of H2O | 20 | 18-30V DC | 1/8 | No | 7/32" | 4 | 3 5/16" | 2 15/16" | IP56, NEMA 4 | 0000000 | 000000000 |
0-3 in. of H2O | 20 | 18-30V DC | 1/8 | No | 7/32" | 4 | 3 5/16" | 2 15/16" | IP56, NEMA 4 | 0000000 | 000000 |
0-5 in. of H2O | 20 | 18-30V DC | 1/8 | No | 7/32" | 4 | 3 5/16" | 2 15/16" | IP56, NEMA 4 | 0000000 | 000000 |
0-10 in. of H2O | 20 | 18-30V DC | 1/8 | No | 7/32" | 4 | 3 5/16" | 2 15/16" | IP56, NEMA 4 | 0000000 | 000000 |
0-25 in. of H2O | 20 | 18-30V DC | 1/8 | No | 7/32" | 4 | 3 5/16" | 2 15/16" | IP56, NEMA 4 | 0000000 | 000000 |
0-1 psi | 20 | 18-30V DC | 1/8 | No | 7/32" | 4 | 3 5/16" | 2 15/16" | IP56, NEMA 4 | 0000000 | 000000 |
- For Use With: Diesel Fuel, Gasoline, Hydraulic Fluid, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Female
- Connection Material: 316 Stainless Steel
- Temperature Range: 0° to 200° F
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range , psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-5 | 50 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 0000000 |
0-10 | 50 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
0-25 | 120 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
0-50 | 250 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
0-100 | 500 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
0-150 | 750 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
Differential Pressure Transmitters with Dial Indicator for Liquids
- For Use With: Diesel Fuel, Gasoline, Hydraulic Fluid, Water
- Accuracy: ±2%
- Pipe Connection: NPT Female
- Housing Material: Brass
- Connection Material: Brass
- Temperature Range: -20° to 200° F
View readings at the source with the dial indicator or remotely using a receiver—these transmitters measure the difference in pressure between two inputs in liquid applications. The dial indicator operates independently of the transmitter and shows differential pressure in real time for troubleshooting. Also known as transducers, these transmitters convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. You’ll sometimes see them used to indicate a filter is clogged in a pump or cooling system. Rated NEMA 4X, these transmitters protect against dirt, washdown, and corrosion. They are also rated IP65 for protection from dust and rinsing. All are CSA certified, so they meet Canadian safety standards.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA, 0-5V DC Output Signal—Screw Terminals | |||||||||||
0-25 in. of H2O | 1,500 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2" | 4 7/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 0000000 |
0-1 psi | 1,500 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2" | 4 7/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-5 psi | 1,500 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2" | 4 7/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-15 psi | 5,000 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2 5/8" | 2 15/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-30 psi | 5,000 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2 5/8" | 2 15/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-50 psi | 5,000 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2 5/8" | 2 15/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
Differential Pressure Transmitters with Electronic Switch Outputs
- For Use With: Air, Hydraulic Fluid, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Female
- Housing Material: Glass-Reinforced Polyester
- Connection Material: 316L Stainless Steel
- Temperature Range: 14° to 158° F
Get the flexibility of a differential pressure transmitter and a switch in one. These transmitters can work as a traditional transmitter using an analog output but also have electronic switch outputs and IO Link compatibility, making them great for advanced automation applications. Also known as transducers, they measure the difference in pressure between two inputs and convert it to electrical signal. Connect them to your programmable logic controller or receiving device to monitor differential pressure remotely, activate automated controls, or trigger alarms when they reach the set pressure. A digital display lets you monitor the differential pressure and troubleshoot issues at the source. It rotates for readability.
You’ll often see these transmitters used to indicate a clogged filter or help maintain a certain pressure in HVAC systems, pumps, and cooling systems. NEMA and IP rated, they protect against dirt, dust, corrosion, weather, washdowns, and temporary submersion.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
For technical drawings and 3-D models, click on a part number.
Configurable Analog Transmitter Output | Configurable Digital Switch Output | Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | No. of | Signal | No. of | Signal Type | Mounting Hardware Included | Dia. | No. of | Environmental Rating | Each | |
5-Pole Micro M12 Plug Connection | |||||||||||||||
0-15 | 2,500 | 15-32V DC | 1/4 | 4 13/16" | 3" | 1 | 0-10V DC, 4-20 mA | 2 | PNP, NPN | No | 3/16" | 2 | IP65, IP67, NEMA 4X, NEMA 6 | 0000000 | 000000000 |
0-100 | 2,500 | 15-32V DC | 1/4 | 4 13/16" | 3" | 1 | 0-10V DC, 4-20 mA | 2 | PNP, NPN | No | 3/16" | 2 | IP65, IP67, NEMA 4X, NEMA 6 | 0000000 | 00000000 |
0-500 | 2,500 | 15-32V DC | 1/4 | 4 13/16" | 3" | 1 | 0-10V DC, 4-20 mA | 2 | PNP, NPN | No | 3/16" | 2 | IP65, IP67, NEMA 4X, NEMA 6 | 0000000 | 00000000 |
Differential Pressure Transmitters with Dial Indicator for Air
- For Use With: Air
- Accuracy: ±2%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: Aluminum
- Temperature Range: 20° to 120° F
Check the difference in air pressure between two inputs at the source using the dial indicator or remotely using a receiver. The dial indicator on these transmitters operates independently and shows differential pressure in real time for troubleshooting. Also known as transducers, these transmitters convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are CE marked, so they meet European safety standards.
When measuring pressure in ductwork, pair them with a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range , in. of H2O | Max. Input Pressure, psi | Input Voltage | Pipe Size | For No. of Wires | Mounting Hardware Included | Thread Size | No. of | Dia. | Specifications Met | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-0.5 | 10 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 0000000 |
0-1 | 10 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
0-2 | 2 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
0-3 | 2 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
0-6 | 10 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
0-10 | 2 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
0-20 | 11 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
0-30 | 11 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
Easy-Setup Differential Pressure Transmitters
- For Use With: Air, Hydraulic Fluid, Water
- Accuracy: ±0.075%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: Hastelloy
- Temperature Range: -40° to 185° F
Measure the difference in pressure between two process lines without needing to program your receiving device to correct for errors. These transmitters automatically compensate for errors caused by vibration and temperature changes. Use the keypad to set the pressure range, choose the unit of measure, and zero the transmitter. These transmitters convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. They're often used to indicate a filter is clogged or to maintain a certain pressure in HVAC systems, heat exchangers, chillers, and pumps. All transmitters meet IP66 and NEMA 4X for use in washdown and corrosive environments and have a hastelloy diaphragm to resist harsh chemicals.
Transmitters will only provide accurate readings within the rated pressure range. These transmitters connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. They can also be configured using three or four wires.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Communication Protocol | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | ||||||||||||
0-25 in. of H2O | 3,625 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 000000000 |
0-200 in. of H2O | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
0-1,000 in. of H2O | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
0-150 psi | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
0-450 psi | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
0-1,500 psi | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
Hazardous Location Easy-Setup Differential Pressure Transmitters
- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water
- Accuracy: ±0.075%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: Hastelloy
- Temperature Range: -40° to 185° F
Safe for use in environments where flammable gases and vapors are present, these transmitters measure the difference in pressure between two process lines without needing to program your receiving device to correct for errors. They meet NEC safety standards for protection against an explosion. These transmitters automatically compensate for errors caused by vibration and temperature changes. Set the pressure range with the keypad, select the unit of measure, and zero the transmitter. They convert differential pressure into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers (PLCs), and motor speed controls, to monitor pressure or control equipment. You’ll often see them used to indicate a clogged filter or help maintain a certain pressure in heat exchangers, chillers, HVAC systems, and pumps. Rated IP66 and NEMA 4X, they protect against dirt, dust, corrosion, weather, and washdowns, and the hastelloy connection protects against harsh chemicals.
Transmitters will only provide accurate readings within the rated pressure range. Most often, these transmitters connect using two wires. The same wire that sends a signal to the receiver also powers the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. Three- and four-wire configurations are also possible.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Communication Protocol | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | ||||||||||||
0-25 in. of H2O | 3,625 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 000000000 |
0-200 in. of H2O | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
0-1,000 in. of H2O | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
0-150 psi | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
0-450 psi | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
0-1,500 psi | 5,800 | 11-55V DC | 1/4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
Remote Displays for Pressure Transmitters
- Accuracy: 0.03%
- Display Style: Dual Line, Red LED
- Display Count: -99,999 to 999,999
- Wire Connection Type: Screw Terminals
- Enclosure Material: Plastic
- Temperature Range: -40° to 149° F
Monitor pressure from a distance with these remote displays. They support five different input mA current and DC voltage signals, so they can be used with most common transmitters. Settings are saved even when power is turned off. To prevent tampering, they have a lockout feature that requires a password to modify settings. They are rated NEMA 4X for protection from corrosion and washdowns.
The display with two SPDT (single pole, double throw) relays can be used to send control signals for process-control systems.
Input Signal | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input AC Voltage | Transmitter Power Supply | No. of Signal Inputs | Current, mA | Voltage | Selection | Relay Current | For DIN Panel Cutout Size | Environmental Rating | Each | |
With Lockout, USB Cable | ||||||||||
85-265V AC | 24V DC | 1 | 0-20, 4-20 | 0-5V DC, 0-10V DC, 1-5V DC | Switch | __ | 1/8 | IP65, NEMA 4X | 00000000 | 0000000 |
With Two SPDT (Single Pole, Double Throw) Relays, Alarm LED Indicator, Lockout, USB Cable | ||||||||||
85-265V AC | 24V DC | 1 | 0-20, 4-20 | 0-5V DC, 0-10V DC, 1-5V DC | Switch | 3 A @ 120 V AC, 3 A @ 240 V AC | 1/8 | IP65, NEMA 4X | 00000000 | 000000 |