About Wire and Cable
More
Duct-Rated Ethernet Cable
- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Insulation:
Outer: PVC Plastic
Inner: See table
Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Inner Insulation Material | Inner Insulation Color | Features | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 165° | 0.21" | FEP/Polyolefin Plastic Blend | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | __ | 0000000 | 00000 | 00000 | ||
6 | 350 MHz | 23 | 8 | 23/8 | 165° | 0.23" | FEP/Polyolefin Plastic Blend | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | __ | 0000000 | 0000 | 000 | ||
Shielded Solid Wire | ||||||||||||||
6 | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | FEP Plastic | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | Uninsulated Ground Wire | Gray | 000000 | 0000 | 0000 |
Duct-Rated Oil-Resistant Ethernet Cable
- Use For: Data
- Flexible
- Max. Temperature: 300° F
- Insulation: FEP Plastic
Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Length, ft. | 1-99 | 100-Up | |
Solid Wire | |||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 0.19" | Black | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | 000000 | 00000 | 00000 | |
6 | 350 MHz | 23 | 8 | 23/8 | 0.21" | Black | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | 000000 | 0000 | 0000 |
Duct-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.11" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 4 | 22/4 | 0.13" | White | Black, Green, Red, White | __ | CMP, CL3P | UL Listed, C-UL Listed | 0000000 | |||||
22 | 6 | 22/6 | 0.16" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.19" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | __ | CMP, CL3P | UL 13, UL 444 | 0000000 | |||||
22 | 12 | 22/12 | 0.23" | White | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | __ | CMP, CL3P | UL 13, UL 444 | 0000000 | |||||
18 | 2 | 18/2 | 0.14" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.15" | White | Black, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.17" | White | Black, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.21" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.16" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.2" | White | Black, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.21" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.14" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 4 | 22/4 | 0.15" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.19" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.16" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.19" | White | Black, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.2" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.23" | White | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.19" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.22" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.22" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 |
Access Control Cable
- Use For: Buildings
- Flexible
- Temperature Range: 32° to 165° F
- Insulation: PVC Plastic
Wire multiple components in your security system using a single cable. This cable bundles together four color-coded cables that correspond to each part of an access point: the card reader, the door contact, the lock, and the exit sign. Each interior cable is labeled with the component it matches. All four interior cables have a layer of foil around them to prevent signal interference from nearby devices. Designated CMP, it has a flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. It’s also known as plenum cable. It’s rated FT6, so it meets requirements for preventing the spread of flames and smoke based on a timed test with material mounted to a horizontal tray.
For technical drawings and 3-D models, click on a part number.
Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Application | Ga. | No. of | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 25 ft. Lg. | 50 ft. Lg. | 100 ft. Lg. | 200 ft. Lg. | |
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
Card Reader Door Contact Exit Sign Lock | 22 22 22 18 | 6 2 4 4 | 22/6 22/2 22/4 18/4 | 2.2 A @ 86° F 2.2 A @ 86° F 2.2 A @ 86° F 4 A @ 86° F | 0.46" | Yellow | Blue, Gray, Orange, White | CMP | Flame Rated FT6 | 0000000 |
Duct-Rated Ethernet Cords
Also known as plenum-rated cords, these CMP ethernet cords have flame-resistant, low-smoke insulation and can be used without conduit in ductwork and above a drop ceiling. The RJ45 plugs on each end connect to Ethernet equipment, such as computers, IO modules, and programmable logic controllers (PLCs). Not only do these cords transmit data, but they also power devices that are Power over Ethernet (PoE) compatible. They’re often used with EtherNet/IP, Profinet, and EtherCAT systems.
Duct-Rated HDMI Video Cords
Run high-definition signals through duct, above drop ceilings, and below raised floors without using conduit. These cords are plenum rated, so their insulation resists fire and doesn’t produce smoke. Connect these cords to monitors, TVs, and projectors. Each end has both an HDMI plug and a micro-HDMI socket, so you can connect multiple devices to the cord at once. The plugs are gold plated to resist corrosion and maintain signals over time.
Note: These cords only transmit signals in one direction. Ends are labeled “Source” or “Display” to help you install the cord.
For technical drawings and 3-D models, click on a part number.